Strain Measurement
3D Non-Contact
Extensometers
Vector 3D Non-Contact Extensometer for Universal Testing Machines
Products > Accessories > Extensometers > Vector 3-D
Vector 3D Non-Contact Extensometer for Precision Strain Measurement
Written by Chris Thomas, Universal Grip Company · Reviewed by Frank Bertini · Updated October 17, 2026
The Vector 3D non-contact extensometer measures strain on a tensile, compression or flexure specimen with cameras instead of clip-on arms. It uses digital image correlation (DIC), processed on an onboard GPU, to track the specimen surface in three dimensions and report axial strain, transverse strain and full-field deformation in real time. Because nothing touches the specimen, there is no knife-edge slippage, no added mass on a thin film, no arm to fly off at fracture and no gauge-length limit set by a mechanical frame; the same instrument that measures 0.2 % offset yield on a steel bar can follow a rubber dumbbell to several hundred percent elongation.
This page explains what the Vector measures and how, which of the three models (U200, U70 and B80) fits which specimens, the standards each one serves, how the system connects to an existing universal testing machine through its 0–10 V output, how to set it up for repeatable results, and the mistakes that cause bad optical strain data. For a comparison of 3D DIC with clip-on, long-travel and 2D video extensometers, see our guide to the types of extensometers.
In this guide: What a 3D DIC Extensometer Measures · Who Needs One · How to Choose Between the U200, U70 and B80 · The Vector Models · Standards the Vector Serves · Compatibility: Any Universal Testing Machine · Setup and Best Practices · Common Mistakes with Optical Strain Measurement · Related Equipment · FAQ
What a 3D DIC Extensometer Measures
A conventional extensometer measures one thing: the change in distance between two points a fixed gauge length apart. A DIC extensometer photographs the specimen continuously, locates a pattern of features on its surface (printed marks, a speckle pattern or the material's own texture), and computes how every point moves between frames. From that displacement field it derives:
-
Axial strain over a virtual gauge length that is set in software, not by hardware, so one instrument covers the 10 mm gauge of a miniature coupon and the 200 mm gauge of a composite panel.
-
Transverse strain across the specimen width at the same time, which gives Poisson's ratio and the r-value (plastic strain ratio) for sheet metal without a second extensometer.
-
Full-field strain maps that show where strain concentrates: at a notch, at a tab edge, at a weld, or at the neck forming in a ductile metal.
-
Out-of-plane motion. The 3D part matters: a single camera cannot tell the difference between a specimen stretching and a specimen moving toward the lens. Two-camera stereo DIC measures the surface in three dimensions, so the strain is not corrupted when a specimen bows, twists, thins or rotates in the grips.
The result is delivered two ways: as a calibrated 0–10 V analog signal that any universal testing machine with a strain input channel reads exactly as it would read a clip-on extensometer, and as data in the Vector software, which records the images, strain history and overlays for later analysis or export to the test software or Excel.
Who Needs One
Labs move to non-contact measurement for four reasons, and the Vector is designed around all four.
-
Specimens that a clip-on cannot touch. Thin films, foils, fabrics, soft elastomers, foams, hydrogels and biological tissue are deformed or cut by knife edges and dragged down by the mass of an arm. A camera adds nothing to the specimen.
-
Strains that exceed a clip-on's travel. Rubber per ASTM D412 stretches 300 to 700 %; a clip-on with a 50 % range has to be removed mid-test, which loses the data a long-travel instrument would have kept. The Vector follows the marks to rupture.
-
Fracture that destroys contact instruments. High-strength steel per ASTM E8 and carbon-fibre laminates per ASTM D3039 fail violently; labs either remove the clip-on before fracture (and lose elongation at break) or replace knife edges regularly. The camera sits 280 mm or more away.
-
Properties that need two axes or a strain map. Poisson's ratio, r-value for forming simulations, strain at a notch or hole, and the strain field of a composite coupon are either impossible or slow with mechanical devices and routine with DIC.
The same system also ends the lab's dependence on a laser extensometer. Laser units need reflective tape, a specific surface and careful alignment, and they still only measure one axis. Many labs that bought lasers for rubber and plastics in the 2000s are replacing them with DIC because it needs no special surface preparation beyond a mark, works on curved and irregular specimens, holds its accuracy over long gauge lengths, and is easier for technicians to use.
How to Choose Between the U200, U70 and B80
The three Vector models differ in gauge length, field of view and whether they measure one axis or two. Pick by the largest and smallest specimens you test and by whether you need transverse strain.
-
Choose the U200 when your specimens are long: 200 mm gauge lengths on composite panels, full-section rebar and rod, long plastic and rubber specimens, and any test where a wide field of view matters more than resolving a 2 mm wide coupon.
-
Choose the U70 for small and medium coupons measured on one axis: metals per E8 on 25 and 50 mm gauge lengths, plastics per D638, miniature specimens down to 2 mm wide, and any lab whose work is mostly axial modulus, yield and elongation on specimens under 50 mm gauge.
-
Choose the B80 when transverse strain is part of the data: Poisson's ratio on metals, composites and plastics, r-value on sheet, biaxial strain on small flat or round specimens, and multi-axis deformation studies. It covers axial gauge lengths from 7.5 to 70 mm, so it also does the U70's axial work.
If you are unsure, start from the gauge lengths your standards require (the gauge-length guide lists them by ASTM method) and from the smallest specimen width you run. Those two numbers usually decide the model; our applications engineers confirm the fit from a specimen drawing before quoting.
The Vector Models
U200 non-contact 3D extensometer (200 mm gauge length)
The U200 is the long-gauge model, built for tensile tests that call for a 200 mm gauge length or a wide field of view. The DIC engine and onboard GPU give real-time, high-resolution strain at speed, and the contact-free measurement protects delicate and high-elongation specimens through fracture. It is the model for composite panels and laminates, long plastic and elastomer specimens, reinforcing bar and other full-section products, and for labs that want one camera system to cover a range of specimen lengths. It outputs the same calibrated signal as the other models, so it connects to any major universal testing machine.
U70 uniaxial 3D extensometer (10 to 50 mm gauge length)
The U70 is the precision uniaxial model for small coupons. Its gauge length is adjustable from 10 mm to 50 mm, it measures specimens as narrow as 2 mm, and it works at a lens-to-specimen distance of 280 to 320 mm, which leaves room for grips, a chamber window or a fixture between camera and specimen. It is the natural choice for ASTM E8 metals coupons on 25 and 50 mm gauge lengths, ASTM D638 plastics, thin foil per ASTM E345, wire and small machined specimens, replacing a clip-on wherever knife edges slip, mark or cannot be removed before fracture.
B80 biaxial 3D extensometer (7.5 to 70 mm axial, 6 to 25 mm transverse)
The B80 measures axial and transverse strain simultaneously. Its axial gauge length adjusts from 7.5 to 70 mm and its transverse gauge from 6 to 25 mm; it accepts flat or round specimens as small as 1.5 mm (flat) or 2 mm (round) axially and 10 mm (flat) or 12.5 mm (round) transversely, at a working distance of 285 to 315 mm. With both axes recorded on every frame it gives Poisson's ratio directly, the plastic strain ratio (r-value) that sheet-forming engineers need, and full-field strain for multi-axis deformation analysis on specimens too small for mechanical biaxial extensometers.
All three models ship with the Vector software for setup, calibration and capture, and with the cabling and signal interface for your machine. Model-level accuracy classes, camera resolution and frame rates are on the data sheets; ask for the sheet for the model you are considering.
Standards the Vector Serves
Most tensile standards specify the extensometer by accuracy class rather than by type, so a DIC extensometer that meets the class is acceptable wherever a clip-on is. The common cases:
-
ASTM E8 / E8M and ISO 6892-1 (metals): yield by offset or extension-under-load needs a Class B2 (ASTM E83) or Class 1 (ISO 9513) extensometer; elongation to fracture a Class C or D. A DIC system verified to the class covers both, and keeps measuring through fracture, which a removed clip-on cannot.
-
ASTM D638 and ISO 527-2 (plastics): modulus needs a Class B2 extensometer on a 50 mm (Type I) or 25 mm gauge; elongation at break on ductile plastics runs past any clip-on's range. One U70 or B80 does both.
-
ASTM D3039 and ISO 527-4/-5 (composites): chord modulus between 1,000 and 3,000 µε plus Poisson's ratio from transverse strain; the B80 replaces the strain gauges or the two-extensometer setup, and the strain map shows bending and tab-edge concentration that the standard asks you to check.
-
ASTM D412 and ISO 37 (rubber): elongation on 25 mm bench marks to several hundred percent; the Vector tracks the marks to rupture with no contact.
-
ASTM D882 (thin film): modulus and elongation on films too thin to clamp an extensometer to.
-
ASTM D5379 (composite shear): shear strain from the ±45° displacement field instead of a strain-gauge rosette on every specimen.
-
ASTM A370, A615 and F606 (steel products, rebar, fasteners): yield and elongation on full-section products that are awkward or unsafe to fit with a contact extensometer.
For DIC specifically, ASTM E2208 (digital image correlation practice) and ASTM E83 / ISO 9513 (extensometer verification) are the documents your quality system will cite; the Vector is verified against a calibrated displacement reference in the same way as a clip-on.
Compatibility: Any Universal Testing Machine
The Vector outputs a calibrated 0 to 10 V analog signal proportional to strain. Any universal testing machine or tensile tester with a strain-gauge or auxiliary analog input channel reads it as it would read a clip-on extensometer, so the machine's own software still does the modulus, yield and elongation calculations and the test runs exactly as before. Universal Grip supplies the cable and signal interface for the machine you have, including:
-
Instron frames (the Vector is an Instron-compatible extensometer on any frame with a strain channel, including older 25-pin D-connector inputs)
-
MTS, Shimadzu, Tinius Olsen, ZwickRoell, ADMET and United frames
-
Galdabini universal testing machines, where the Vector integrates with the Graphwork software supplied with our benchtop and floor-standing machines
-
Mark-10 and other small testers with an analog input, for film, rubber and packaging work on a tensile tester
Because the camera does not mount on the specimen, it does not care which grips you use: hydraulic wedge grips, mechanical wedge grips, pneumatic grips or fixtures all work, and the system is routinely fitted to machines that already have a clip-on, with the two selected per test. Fitting a camera system to a machine you already own is covered in our article on retrofitting a video extensometer to an existing testing machine.
Setup and Best Practices
-
Mark the specimen. DIC needs features to track: two gauge marks for axial strain, a speckle or stencil pattern for full-field maps. Our gauge-length marking tool prints repeatable marks at the standard gauge length in seconds; the sample marking guide shows what works on metals, plastics, rubber and fabrics.
-
Respect the working distance. Set the camera at the distance given for the model (280 to 320 mm for the U70, 285 to 315 mm for the B80) and square to the specimen; the software's live view confirms focus and alignment before you start.
-
Light evenly. Flat, diffuse light without reflections or flicker; avoid a window behind the operator and direct sunlight on the specimen.
-
Calibrate the gauge length. The software's quick gauge-length calibration takes a minute; do it after any camera move and as part of the daily check.
-
Verify. Run a calibrated displacement reference or a known-modulus specimen when you commission the system and at your calibration interval, and record the extensometer class achieved; this is what the auditor asks for.
-
Watch the overlay. The live overlay shows the tracked points and the strain map during the test; a jump in the overlay means a mark was lost (glare, a slipped mark, a hand in the frame), and the test can be stopped and repeated rather than discovered later.
-
Chambers. For hot or cold testing the camera views the specimen through the window of an environmental chamber; keep the window clean and avoid condensation on the inside, and expect a short settling time as the air inside stops shimmering.
Common Mistakes with Optical Strain Measurement
-
Marks too small, too faint or too glossy for the camera to lock on, especially on polished metal and black rubber.
-
Camera not square to the specimen, so the axial gauge is foreshortened; the 3D system corrects for out-of-plane motion but still wants a square start.
-
Operator or crosshead shadow moving across the specimen during the test.
-
Running a 2D (single-camera) video extensometer on a specimen that twists or bows; the Vector's stereo measurement exists for exactly this case.
-
Comparing DIC elongation with clip-on elongation without the same gauge length; set the virtual gauge to the standard's value.
-
Leaving the machine's strain channel scaled for the old clip-on; re-enter the Vector's volts-per-strain scaling when you commission it.
-
Expecting a laser-extensometer reflective strip to work as a DIC mark; it does not, and it is not needed.
Related Equipment
-
Video extensometers: our full range of camera-based systems, including 2D models for routine work.
-
Clip-on extensometers: for labs that need a contact instrument alongside the camera, or a low-cost Class B2 device for modulus only.
-
Long-travel extensometers: contact instruments for elastomers and plastics where a camera is not wanted.
-
Gauge-length marking tool: repeatable marks for every specimen.
-
Universal testing machines and Mark-10 tensile testers: complete systems supplied with the Vector configured and the strain channel scaled.
-
Environmental chambers: camera-compatible chambers for hot and cold testing.
Still deciding between contact and non-contact? Our articles on when to use an extensometer and video versus clip-on extensometers walk through the trade-offs, and the extensometers hub compares every type we supply.
Vector 3D Extensometer FAQ
What is the Vector 3D extensometer?
A non-contact extensometer that measures specimen strain with cameras and digital image correlation (DIC), processed on an onboard GPU. It reports axial strain, transverse strain and full-field deformation in real time and outputs a calibrated 0–10 V signal that any universal testing machine reads as extensometer input.
What is the difference between the U200, U70 and B80?
The U200 is the long-gauge model for 200 mm gauge lengths and large specimens. The U70 is a uniaxial model with a 10–50 mm adjustable gauge length for specimens as narrow as 2 mm. The B80 is biaxial, measuring axial (7.5–70 mm gauge) and transverse (6–25 mm) strain at the same time for Poisson's ratio and r-value.
Will it work with my Instron, MTS or Shimadzu machine?
Yes. The Vector outputs a calibrated 0–10 V analog strain signal, so any universal testing machine with a strain or auxiliary analog input can use it. Universal Grip supplies the cable and interface for Instron, MTS, Shimadzu, Tinius Olsen, ZwickRoell, Galdabini and other frames.
Does a DIC extensometer meet ASTM E83 or ISO 9513 accuracy classes?
Extensometer standards specify accuracy, not technology, so a DIC system verified against a calibrated displacement reference can be classed like any other extensometer. Ask for the data sheet for the class achieved by each model over its gauge-length range.
Can it measure Poisson's ratio?
The B80 measures axial and transverse strain on every frame, so Poisson's ratio (and the plastic strain ratio, r-value, for sheet metal) is calculated directly without a second extensometer or strain gauges.
Why 3D instead of a 2D video extensometer?
A single camera cannot distinguish strain from motion toward or away from the lens. The Vector's stereo (3D) measurement tracks the surface in three dimensions, so specimens that bow, twist, thin or rotate in the grips still give correct strain.
Does the specimen need special preparation?
Only a mark or pattern the camera can track: two gauge marks for axial strain, a speckle or stencil pattern for full-field maps. No reflective tape, no knife-edge seating. Our marking tool and sample-marking guide cover metals, plastics, rubber and fabrics.
Can it replace a laser extensometer?
Yes, and most labs find it easier: no reflective strips, no fine alignment, it works on curved and irregular specimens, it measures two axes, and it holds accuracy over long gauge lengths.
Can it be used inside an environmental chamber?
Yes. The camera views the specimen through the chamber window at its normal working distance, so hot and cold tensile tests get non-contact strain without arms or cables inside the chamber.
How is the data recorded?
Two ways at once: the 0–10 V signal goes to the testing machine's software, which calculates modulus, yield and elongation as usual, and the Vector software records images, strain histories and overlays, with export to the test software or Excel.
Want to see the Vector on your specimens? Contact Universal Grip with your specimen sizes, gauge lengths, test standards and machine make/model and we will recommend the right model, quote it, and arrange a live demo.

U200 Non-Contact 3D Extensometer (200 mm Gauge Length)
The U200 is a high-performance non-contact extensometer designed for demanding tensile testing applications requiring a 200 mm gauge length. Leveraging advanced Digital Image Correlation (DIC) technology and an onboard GPU, the U200 delivers real-time, high-resolution strain measurement with exceptional accuracy and speed. Its contact-free design ensures damage-free testing of delicate or high-elongation specimens, while the integrated GPU enables fast image processing for seamless operation. Compatible with all major universal testing machines, the U200 is ideal for precision strain analysis across metals, composites, plastics, and more.

U70 Uniaxial 3D Extensometer (50 mm Gauge Length)
The Vector U70 is a precision-engineered uniaxial non-contact extensometer designed for high-accuracy strain measurement in demanding materials testing applications. Featuring an adjustable gauge length from 10 mm to 50 mm, the U70 is ideal for small specimens with a minimum width of just 2 mm. Its advanced optical system operates at distances between 280 mm and 320 mm, ensuring flexible setup and reliable alignment even in challenging test environments. Leveraging cutting-edge Digital Image Correlation (DIC) and robust image processing, the Vector U70 delivers real-time, non-contact strain measurement for metals, composites, plastics, and more—all while eliminating the errors and specimen damage common with clip-on systems.

B80 Biaxial 3D Extensometer (70 mm Gauge Length)
The Vector B80 is a high-precision biaxial non-contact extensometer designed for simultaneous axial and transverse strain measurement in advanced materials testing applications. With an adjustable axial gauge length of 7.5 mm to 70 mm and transverse gauge length of 6 mm to 25 mm, the B80 offers exceptional flexibility for testing small or intricate specimens. Compatible with flat and round samples, the system supports minimum specimen sizes as small as 1.5 mm (flat) or 2 mm (round) axially, and 10 mm (flat) or 12.5 mm (round) transversely. Operating at a working distance of 285 mm to 315 mm, the Vector B80 leverages Digital Image Correlation (DIC) technology to deliver accurate, full-field strain measurement—ideal for Poisson’s ratio calculations, r-value testing, and multi-axis deformation analysis.