top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Zero-Span Paper Tensile Fixture ISO 15361

UGC-ST-460 zero-span paper tensile fixture with ball-bearing guides by Universal Grip
UGC-ST-460 zero-span paper tensile fixture with ball-bearing guides by Universal Grip
UGC-ST-460 Zero-Span Paper Tensile Fixture ISO 15361 by Universal Grip, view 2
UGC-ST-460 Zero-Span Paper Tensile Fixture ISO 15361 by Universal Grip, view 3
UGC-ST-460 Zero-Span Paper Tensile Fixture ISO 15361 by Universal Grip, view 4

Zero-Span Paper Tensile Fixture ISO 15361 – Standard or Pneumatic

Zero-span tensile fixture for paper fiber strength, designed for ISO 15361, TAPPI T231 and ASTM D5804 tests, with ball-bearing guides and a pneumatic option.

Brand: Universal Grip  |  Model: UGC-ST-460  |  ● Configured to order

  • Designed for zero-span tests such as ISO 15361, TAPPI T231 and ASTM D5804

  • Jaws clamp the strip with zero span, so fiber strength is measured, not the fiber network

  • Ball-bearing guides keep the jaws aligned

  • Pneumatic version for uniform, repeatable clamping

  • Stainless steel pneumatic version works from 0 to +120 °C (32 to 248 °F)

  • Pull rods let the pneumatic version run inside a temperature chamber

  • Female clevis coupling with Ø 15.9 mm (5/8 in) pin

Standards: ISO 15361  ·  TAPPI T231  ·  ASTM D5804

Trusted by Global Companies

Zero-span tensile fixture for paper and pulp fiber strength

The UGC-ST-460 is a zero-span tensile fixture designed for tests such as ISO 15361, TAPPI T231 and ASTM D5804. Pulp and paper mills, recycled-fiber processors and research laboratories use zero-span testing to judge the strength of the fibers themselves, separately from how well those fibers are bonded into a sheet.

 

How zero-span clamping works

In an ordinary strip tensile test the jaws start some distance apart, so the result reflects the whole fiber network. Here the two clamping jaws grip the strip with no gap between them. With no free span, the test measures the strength of the individual fibers rather than the network. Ball-bearing guides keep the two jaws aligned as the testing machine pulls them apart.

 

Standard and pneumatic versions

  • Standard version – ball-bearing guides and a female clevis coupling for a Ø 15.9 mm (5/8 in) pin

  • Pneumatic version – stainless steel body with guides, air-operated clamping, rated from 0 to +120 °C (32 to 248 °F), supplied with pull rods for use in a temperature chamber

The pneumatic version gives uniform, repeatable clamping from one strip to the next, which helps when many strips or handsheets are tested each shift. Its pull rods allow the fixture to work inside an environmental chamber for tests above room temperature.

Maximum load is on request for both versions, and the data sheet gives a body material and temperature range for the pneumatic version only. We confirm the details of the standard version at quote.

 

Specimens and applications

The fixture takes paper strips and pulp handsheets. Typical users include:

  • Pulp and paper mills

  • Fiber strength research groups

  • Recycled fiber evaluation

  • Paper testing laboratories

 

Choosing a configuration

Start with the clamping method: standard or pneumatic. Then consider temperature; if you test in a chamber, the stainless steel pneumatic version with pull rods is the one to specify. Last comes the machine connection. The fixture pins into the load string through a Ø 15.9 mm clevis, and adapters cover other couplings.

The fixture is supplied for mounting in a universal testing machine such as our Galdabini benchtop frames. Because capacity is on request, we settle the fixture rating, load cell and coupling together when we quote. For the pneumatic version, tell us what compressed air supply you have available.

 

Related paper strength fixtures

Zero-span results are often read alongside other sheet properties. The UGC-ST-470 z-direction tensile fixture pulls paperboard apart through its thickness, and the UGC-ST-490 Finch device handles wet tensile tests on paper and tissue.

Tell us whether you want standard or pneumatic operation, your test temperature and your machine coupling, and we'll configure the fixture — request a quote.

Product video

At a glance

  • Test type: Zero-span tensile

  • Standards: ISO 15361, TAPPI T231, ASTM D5804

  • Specimen: Paper strips, pulp handsheets

  • Guides: Ball-bearing guides

  • Operation: Standard or pneumatic

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin

Zero-Span Paper Tensile Fixture ISO 15361 Specifications

TEST TYPE

Zero-span tensile

 

STANDARDS

ISO 15361, TAPPI T231, ASTM D5804

 

SPECIMEN

Paper strips, pulp handsheets

 

GUIDES

Ball-bearing guides

 

OPERATION

Standard or pneumatic

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin

 

MATERIAL

Stainless steel (pneumatic version)

 

TEMPERATURE RANGE

0 to +120 °C (pneumatic version)

 

MAX. LOAD

On request

 

PART REF.

UGC-ST-460

 

Models & Options

  • Standard version — Ball-bearing guides, Ø 15.9 mm (5/8 in) clevis coupling (Specify at order)

  • Pneumatic version — Stainless steel body, guides, 0 to +120 °C, pull rods for temperature chamber use (Specify at order)

  • Other couplings — Adapters or custom couplings for other machine connections (On request)

What's Included

  • Zero-span fixture with two clamping jaws and ball-bearing guides

  • Female clevis coupling for Ø 15.9 mm (5/8 in) pin

  • Pneumatic version: stainless steel body and pull rods for temperature chamber use

  • Dimensional drawings and 3D models available on request

Supported Test Standards

  • ISO 15361 — Zero-span tensile strength of pulps

  • TAPPI T231 — Zero-span breaking strength of pulp

  • ASTM D5804 — Zero-span tensile strength of paper

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-470 Paperboard Z-Direction Tensile Fixture ISO 15754

UGC-ST-470 Paperboard Z-Direction Tensile Fixture ISO 15754

Z-direction tensile fixture for paper and paperboard, supplied with two nickel-plated steel tester platens and an alignm

UGC-ST-490 Finch Wet Tensile Fixture ISO 12625-5

UGC-ST-490 Finch Wet Tensile Fixture ISO 12625-5

Finch device for wet tensile strength of paper, tissue paper and tissue products, with stainless steel bar and aluminum

UGC-ST-450 Cardboard Compression Fixture

UGC-ST-450 Cardboard Compression Fixture

Aluminum bar-and-channel fixture for compression tests on cardboard and paperboard, in several bar lengths including a 3

UGC-ST-440 Paper and Corrugated Board Bend Fixture TAPPI T829

UGC-ST-440 Paper and Corrugated Board Bend Fixture TAPPI T829

Stainless steel blade-and-channel bend fixture for paper and corrugated board, designed for TAPPI T829 tests at loads up

Zero-Span Paper Tensile Fixture ISO 15361 FAQ

What does a zero-span tensile test measure?

With the two jaws clamped against each other and no free span, the test measures the strength of the individual fibers rather than the bonded fiber network. Mills use it to assess fiber quality.

 

Which standards is the fixture used for?

It is designed for zero-span tests such as ISO 15361, TAPPI T231 and ASTM D5804.

 

What is the difference between the standard and pneumatic versions?

The standard version has ball-bearing guides and a Ø 15.9 mm (5/8 in) clevis coupling. The pneumatic version adds air-operated clamping for uniform, repeatable clamping, a stainless steel body and pull rods for chamber use.

 

Can it be used in a temperature chamber?

Yes, the stainless steel pneumatic version is rated from 0 to +120 °C (32 to 248 °F) and comes with pull rods for use in a temperature chamber.

 

What is the maximum load?

The data sheet lists maximum load as on request. Tell us the forces you expect and we will confirm the rating with your quote.

 

What specimens does it take?

Paper strips and pulp handsheets.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page