top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Zipper Test Fixture DIN 3419-1

UGC-ST-790 zipper test fixture with clamping frame, guide rods and graded cylindrical weights by Universal Grip
UGC-ST-790 zipper test fixture with clamping frame, guide rods and graded cylindrical weights by Universal Grip
UGC-ST-790 Zipper Test Fixture DIN 3419-1 by Universal Grip, view 2
UGC-ST-790 Zipper Test Fixture DIN 3419-1 by Universal Grip, view 3
Product photo 4

Zipper Test Fixture DIN 3419-1

Dead-weight zipper test fixture with a clamping frame, guide rods and a graded weight set, designed for DIN 3419-1 tests on slide fasteners.

Brand: Universal Grip  |  Model: UGC-ST-790  |  ● Configured to order

  • Frame with knob-tightened clamping heads holds the zipper tapes

  • Set of graded cylindrical weights for different load classes

  • Guide rods keep the loaded zipper aligned

  • Separate slider pull attachment included with the frame

  • Steel construction with a corrosion-resistant nickel finish

  • Weight set matched to the zipper size classes you test

  • Test arrangement designed for DIN 3419-1

Standards: DIN 3419-1

Trusted by Global Companies

Dead-weight zipper test fixture for DIN 3419-1

The UGC-ST-790 is a special fixture for testing zippers (slide fasteners), designed for DIN 3419-1. It loads the fastener with a set of graded cylindrical weights, so the zipper and its slider see a defined, steady load. Zipper manufacturers, apparel and luggage QC departments, footwear fastener suppliers and textile testing laboratories use it to check that a fastener holds and operates correctly under the loads specified for its size class.

 

How the fixture is built

The zipper tapes are clamped in a frame by clamping heads that are tightened with knobs, so specimens are loaded and released by hand. Graded cylindrical weights then apply the defined loads to the zipper and slider. Guide rods keep the loaded zipper aligned while the weight hangs on it. A separate slider pull attachment is included with the frame for the checks that load the slider.

  • Clamping: frame with knob-tightened clamping heads for the zipper tapes.

  • Loading: set of graded cylindrical weights for different load classes.

  • Alignment: guide rods.

  • Slider loading: separate slider pull attachment, included with the frame.

  • Material: steel with a corrosion-resistant nickel finish.

 

Weight set and load range

The maximum load is set by the weight set and not by a single rating. Different zipper size classes call for different loads, so tell us which classes you test and we will match the weight set to them. The load range for your set is confirmed on the quote.

 

Machine mounting

Because the load comes from dead weights, the coupling is on request and is quoted only if you need the fixture mounted on a testing machine. If you do, tell us the machine model and we will confirm the connection and any adapters required.

 

Where it fits in a zipper lab

This fixture covers strength and function checks under dead-weight load. For force-measuring tests on a testing machine, see the UGC-ST-900 zipper operability fixture, which measures the force to open and close the zipper, and the UGC-ST-800 zipper pull tab twist fixture for sliders and pull tabs. Grips for the tapes and fabrics around the fastener are on our textile testing page.

 

Typical applications

  • Zipper manufacturers

  • Apparel and luggage quality control

  • Footwear fasteners

  • Textile testing laboratories

Tell us the zipper size classes you test and whether machine mounting is required, and we will configure the fixture and weight set. Dimensional drawings and 3D models are available on request. Request a quote.

Product video

At a glance

  • Test type: Zipper strength and function under dead-weight load

  • Loading: Graded cylindrical weights (set)

  • Specimen: Zippers / slide fasteners

  • Clamping: Knob-tightened clamping heads

  • Material: Steel, nickel-plated

  • Max. load: Per weight set; on request

Zipper Test Fixture DIN 3419-1 Specifications

TEST TYPE

Zipper strength and function under dead-weight load

 

LOADING

Graded cylindrical weights (set)

 

SPECIMEN

Zippers / slide fasteners

 

CLAMPING

Knob-tightened clamping heads

 

MATERIAL

Steel, nickel-plated

 

MAX. LOAD

Per weight set; on request

 

COUPLING

On request

 

ALIGNMENT

Guide rods

 

SLIDER ATTACHMENT

Separate slider pull attachment included with the frame

 

STANDARDS NAMED

DIN 3419-1

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-ST-790

 

Models & Options

  • Weight set — Graded cylindrical weights matched to the zipper size classes tested (Specify at order)

  • Machine mounting — Coupling for mounting on a testing machine, if required (On request)

  • Custom versions — Other clamping or loading arrangements (On request)

What's Included

  • Frame with knob-tightened clamping heads and guide rods

  • Set of graded cylindrical weights, matched to the size classes specified at order

  • Separate slider pull attachment

  • Machine coupling only if requested

  • Dimensional drawings and 3D models available on request

Supported Test Standards

  • DIN 3419-1 — Slide fasteners (zippers): testing

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-800 Zipper Pull Tab Twist Fixture

UGC-ST-800 Zipper Pull Tab Twist Fixture

Fixture for the twist strength of zipper pulls and sliders: a knob-tightened vise holds the slider while a hook on a cha

UGC-ST-900 Zipper Operability Fixture

UGC-ST-900 Zipper Operability Fixture

Fixture for the slider operating force of zippers, designed for ASTM D2062, with a vertical clamping frame and 18 mm sli

UGC-ST-780 Button Pull-Off Fixture EN 17394-2

UGC-ST-780 Button Pull-Off Fixture EN 17394-2

200 N pull-off fixture for the attachment strength of buttons on garments, with 3, 5 and 7 mm slotted inserts and a serr

UGC-ST-740 Carpet and Textile Rigidity Fixture

UGC-ST-740 Carpet and Textile Rigidity Fixture

Wedge-indenter fixture that pushes a clamped carpet or textile specimen into a slot to measure its rigidity, for automot

Zipper Test Fixture DIN 3419-1 FAQ

What is the UGC-ST-790 used for?

Testing zippers (slide fasteners) under defined dead-weight loads. The test arrangement is designed for DIN 3419-1.

 

How is the load applied?

By a set of graded cylindrical weights. The zipper tapes are clamped in the frame, and guide rods keep the loaded zipper aligned.

 

What is the maximum load?

It depends on the weight set, which is matched to the zipper size classes you test. The load range is confirmed on the quote.

 

Does it need a testing machine?

The load comes from the weights. A coupling for mounting on a testing machine is available on request; tell us if you need it.

 

Is a slider attachment included?

Yes. A separate slider pull attachment is included with the frame.

 

What do you need to quote it?

The zipper size classes you test and whether machine mounting is required. Contact us with those details.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page