Home › Products › Standard-Specific Test Fixtures › Ceramic Tile Grout and Adhesive Fixture ISO 13007-2





Ceramic Tile Grout and Adhesive Fixture ISO 13007-2 – 50 kN
50 kN guided fixture with four corner clamps for testing ceramic tile adhesives and grouts on specimens up to 65 x 300 x 300 mm.
Brand: Universal Grip | Model: UGC-ST-810 | ● Configured to order
Test arrangement designed for ISO 13007-2 ceramic tile adhesive and grout tests
Accepts specimens up to 65 x 300 x 300 mm (about 2.6 x 11.8 x 11.8 in)
Four corner hold-down clamps secure the substrate
Linear guide rails allow free lateral movement under load
Nickel-coated steel construction, rated to 50 kN (about 11,240 lbf)
Male clevis coupling Ø 31.7 mm (about 1-1/4 in) with self-aligning adapter
Standards: ISO 13007-2
Trusted by Global Companies


























Large-specimen fixture for ceramic tile adhesives and grouts
The UGC-ST-810 is a special fixture for testing ceramic tile adhesives and grouts, with a test arrangement designed for ISO 13007-2. It is laid out around a large platen that takes specimens up to 65 x 300 x 300 mm (about 2.6 x 11.8 x 11.8 in) and is rated to 50 kN (about 11,240 lbf). Manufacturers of tile adhesives and of cementitious and reaction-resin grouts use it in building chemicals development and in construction materials quality control.
How it works
The tile specimen is placed on the platen and secured by four hold-down clamps, one at each corner, which fix the substrate. The platen rides on linear guide rails, so it can move freely sideways while the load is applied and the adhesive layer is loaded without restraint from the fixture. On the machine side, the fixture has a male clevis coupling Ø 31.7 mm (about 1-1/4 in) and is supplied with a self-aligning machine adapter, which lets the load train settle squarely on the specimen.
Specimen size and clamping
Most fixtures for bonded joints are sized for small coupons. This one is made for tile-sized assemblies: anything up to 300 x 300 mm in plan and 65 mm thick fits on the platen. The four clamps sit at the corners and secure the substrate to the platen. If you also test smaller specimens, tell us the sizes so we can confirm how they are clamped.
Which ISO 13007-2 tests?
ISO 13007-2 contains several test methods. The fixture is configured for the method or methods you intend to run, so name them when you ask for a quote and we will confirm the arrangement, including any loading parts your method needs.
Typical applications
Ceramic tile adhesives
Cementitious and reaction-resin grouts
Building chemicals research and development
Construction materials quality control
Construction and machine fit
The fixture is nickel-coated steel and is intended for tests at ambient temperature. With a 50 kN rating it suits a Galdabini 50 kN benchtop universal testing machine or a floor-standing frame. A 300 x 300 mm platen needs room between the columns, so we check the test space of your machine at quote. Adapters connect the Ø 31.7 mm clevis to other couplings. For other bonded-joint tests, see our adhesives testing page. Dimensional drawings and 3D models are available on request.
Send us the ISO 13007-2 test methods you run, your specimen size and your machine coupling, and we will configure the fixture: request a quote.
Ceramic Tile Grout and Adhesive Fixture ISO 13007-2 Specifications
MAX. LOAD
50 kN (11,240 lbf)
TEST TYPE
Adhesive / grout testing on tile specimens
STANDARD
ISO 13007-2
SPECIMEN SIZE
Max. 65 x 300 x 300 mm
CLAMPING
4 corner hold-down clamps
GUIDANCE
Linear guide rails
MATERIAL
Steel, nickel-coated
COUPLING
Male clevis, Ø 31.7 mm
TEMPERATURE RANGE
Ambient
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-810
Models & Options
ISO 13007-2 fixture, 50 kN — Guided platen with four corner clamps for specimens up to 65 x 300 x 300 mm (Specify at order)
Test method configuration — Arrangement set up for the ISO 13007-2 method or methods you specify (Specify at order)
Coupling adapters — Connect the Ø 31.7 mm male clevis to other machine couplings (On request)
Custom specimen sizes — Versions for other specimen dimensions (On request)
What's Included
Fixture with large platen on linear guide rails
Four corner hold-down clamps
Male clevis coupling Ø 31.7 mm
Self-aligning machine adapter
Supported Test Standards
ISO 13007-2 — Ceramic tiles – Grouts and adhesives – Part 2: Test methods for adhesives
Compatible Grips & Fixtures
50 kN Benchtop Universal Testing Machine — Galdabini frame matched to the fixture's 50 kN rating
Floor-Standing Universal Testing Machines — Larger test space for 300 x 300 mm specimens
Adapters — Connect the Ø 31.7 mm clevis to other machine couplings
Adhesives Testing — Grips and fixtures for adhesive and bonded joint tests
Standard-Specific Test Fixtures — Other single-purpose fixtures for construction and product tests
“Customer quote”
Related Equipment
UGC-ST-770 Wood Screw Axial Withdrawal Fixture
C-frame fixture with a split collet for measuring the axial withdrawal resistance of screws from wooden specimens.
UGC-ST-320 Fruit Puncture Fixture
Multi-needle puncture fixture that pierces a batch of olives, cherries or similar small fruit in one stroke for firmness
UGC-ST-760 Laminate Click Joint Strength Fixture
Fixture for the tooth strength of click-locking joints in wood and laminate flooring, for samples 0–20 mm thick, with vi
UGC-ST-330 Razor Blade Texture Probe for Poultry
Razor blade shear probe with an 8.9 mm chisel blade in an anodized aluminum holder for measuring the tenderness of chick
Ceramic Tile Grout and Adhesive Fixture ISO 13007-2 FAQ
What is the UGC-ST-810 used for?
Testing ceramic tile adhesives and grouts on large tile specimens, with a test arrangement designed for ISO 13007-2.
What is the largest specimen it accepts?
65 x 300 x 300 mm (about 2.6 x 11.8 x 11.8 in).
What is the maximum load?
50 kN (about 11,240 lbf).
Why does the platen run on linear guide rails?
The rails allow free lateral movement under load, so the adhesive layer is loaded without restraint from the fixture.
Which ISO 13007-2 test methods can I run on it?
Tell us the method or methods you need when you ask for a quote. The arrangement is confirmed for those methods before you order.
How does it connect to the testing machine?
Through a male clevis coupling Ø 31.7 mm and a self-aligning machine adapter. Adapters are available for other couplings.