top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Mixed-Mode Bend Fixture

UGC-ST-240 mixed-mode bend fixture for composite interlaminar fracture toughness, 10 kN, by Universal Grip
UGC-ST-240 mixed-mode bend fixture for composite interlaminar fracture toughness, 10 kN, by Universal Grip
UGC-ST-240 Mixed-Mode Bend Fixture by Universal Grip, view 2
Product photo 3
Product photo 4

Mixed-Mode Bend Fixture – 10 kN

Lever-loaded mixed-mode I/II bend fixture for interlaminar fracture toughness of unidirectional composites, 10 kN, with a 5/8 in clevis coupling.

Brand: Universal Grip  |  Model: UGC-ST-240  |  ● Configured to order

  • Mixed-mode bend fixture designed for ASTM D6671 interlaminar fracture toughness tests

  • Lever loading combines mode I opening and mode II shear at the crack tip

  • Rated for loads up to 10 kN (about 2,248 lbf)

  • Nickel-plated steel and anodized aluminum construction, 5.56 kg (12.3 lb)

  • Female clevis coupling for a Ø 15.9 mm (5/8 in) pin; others on request

  • Untreated aluminum end blocks available in packs of 5, 10, 25 and 50 pairs

  • Piano hinges for specimen loading available on request

Standards: ASTM D6671

Trusted by Global Companies

Mixed-mode bend fixture for interlaminar fracture toughness of composites

The UGC-ST-240 is a mixed-mode bend (MMB) fixture for measuring the mixed mode I/mode II interlaminar fracture toughness of unidirectional fiber-reinforced polymer matrix composites. It is designed for ASTM D6671 tests and is used in aerospace composite qualification, delamination resistance research, unidirectional prepreg testing and wind blade materials work. The fixture is rated for 10 kN (about 2,248 lbf) and weighs 5.56 kg (about 12.3 lb).

 

How the specimen is held and loaded

A pre-cracked laminate specimen is connected to the fixture through end blocks bonded to the specimen. A lever arm then loads the specimen so that the crack tip sees mode I opening and mode II shear at the same time. The fixture is made from nickel-plated steel and anodized aluminum, so its surfaces are protected against corrosion, and at 5.56 kg it can be lifted onto the machine by one person.

This page covers the hardware. See our complete ASTM D6671 guide for specimen preparation, procedure and calculations.

 

End blocks and hinges

The fixture is supplied as one unit, without end blocks. End blocks are bonded to each specimen, so labs order them in quantity. They are available separately in untreated aluminum, in four pack sizes:

  • 5 pairs

  • 10 pairs

  • 25 pairs

  • 50 pairs

Piano hinges for specimen loading are available on request if you prefer hinges to blocks.

 

Coupling and temperature range

The fixture connects through a female clevis for a Ø 15.9 mm (5/8 in) pin. Other couplings are available on request, and adapters cover machines with a different connection. The standard temperature range is 0 to +70 °C (32 to 158 °F); other ranges are on request.

 

Machine fit

With a 10 kN rating, the fixture suits a Galdabini 10 kN benchtop universal testing machine. It can also be mounted on other frames, provided the load cell range suits the loads your laminates produce; tell us the load range you expect and we will advise. A dimensional drawing is included on the data sheet, and detailed drawings and 3D models are available on request. Other flexure setups are listed under bend testing fixtures.

Tell us your machine coupling, how many end block pairs you need and whether you want piano hinges, and we will put the set together: request a quote.

Product video

At a glance

  • Max. load: 10 kN (2,248 lbf)

  • Test type: Mixed-mode I/II interlaminar fracture

  • Standard: ASTM D6671

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

  • Material: Steel, nickel-plated; aluminum, anodized

  • Temperature range: 0 … +70 °C; other ranges on request

Mixed-Mode Bend Fixture Specifications

MAX. LOAD

10 kN (2,248 lbf)

 

TEST TYPE

Mixed-mode I/II interlaminar fracture

 

STANDARD

ASTM D6671

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

 

MATERIAL

Steel, nickel-plated; aluminum, anodized

 

TEMPERATURE RANGE

0 … +70 °C; other ranges on request

 

WEIGHT

5.56 kg (12.3 lb)

 

SCOPE OF SUPPLY

1 fixture; end blocks ordered separately

 

DRAWINGS

Dimensional drawing on the data sheet; 3D models on request

 

PART REF.

UGC-ST-240

 

Models & Options

  • Mixed-mode bend fixture — 1 fixture, without end blocks (Specify at order)

  • End blocks, 5 pairs — Aluminum, untreated (Specify at order)

  • End blocks, 10 pairs — Aluminum, untreated (Specify at order)

  • End blocks, 25 pairs — Aluminum, untreated (Specify at order)

  • End blocks, 50 pairs — Aluminum, untreated (Specify at order)

  • Piano hinges — For specimen loading in place of end blocks (On request)

  • Other couplings — Made to your machine connection (On request)

What's Included

  • 1 mixed-mode bend fixture with lever arm

  • Female clevis coupling for a Ø 15.9 mm (5/8 in) pin

  • End blocks are not included; order them separately in packs of 5, 10, 25 or 50 pairs

  • Piano hinges are supplied on request

Supported Test Standards

  • ASTM D6671 — Mixed mode I/mode II interlaminar fracture toughness of unidirectional composites

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-260 Composite Laminate Compression Fixture

UGC-ST-260 Composite Laminate Compression Fixture

100 kN anti-buckling compression fixture with diamond-coated clamping surfaces for open-hole and bearing tests on compos

UGC-ST-230 Composite Fastener Pull-Through Fixture Method A

UGC-ST-230 Composite Fastener Pull-Through Fixture Method A

50 kN hardened, nickel-coated steel fixture for fastener pull-through tests on composite plates, designed for ASTM D7332

UGC-ST-250 Composite Fastener Pull-Through Fixture Method B

UGC-ST-250 Composite Fastener Pull-Through Fixture Method B

Fastener pull-through fixture for composite laminates, designed for ASTM D7332 Method B: 20 kN version for M6 fasteners

UGC-ST-220 Advanced Ceramic Joint Shear Fixture

UGC-ST-220 Advanced Ceramic Joint Shear Fixture

Compression-loaded shear fixture for joints in advanced ceramics, rated 2.5 kN, in an ambient version and a +1200 °C hig

Mixed-Mode Bend Fixture FAQ

What is the UGC-ST-240 used for?

Measuring mixed mode I/mode II interlaminar fracture toughness of unidirectional fiber-reinforced polymer matrix composites, with a lever arm that combines opening and shear at the crack tip.

 

Where can I find the test procedure and calculations?

See our complete ASTM D6671 guide for specimen preparation, procedure and calculations. This page covers the fixture hardware.

 

Are end blocks included?

No. The scope of supply is one fixture. Untreated aluminum end blocks are ordered separately in packs of 5, 10, 25 or 50 pairs.

 

Can I use piano hinges instead of end blocks?

Yes. Piano hinges for specimen loading are available on request.

 

What coupling does the fixture have?

A female clevis for a Ø 15.9 mm (5/8 in) pin. Other couplings are available on request, and adapters connect it to other machines.

 

What are the load rating, weight and temperature range?

The fixture is rated for 10 kN (about 2,248 lbf), weighs 5.56 kg (12.3 lb) and is used from 0 to +70 °C. Other temperature ranges are on request.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page