Home › Products › Standard-Specific Test Fixtures › Wood Panel 45 Degree Compression-Shear Fixture





Wood Panel 45 Degree Compression-Shear Fixture – 10 kN / 100 kN
45° compression-shear fixture for wood-base fiber and particle panels, in a 100 kN version with magnetic insert plates and a 10 kN hardened steel version.
Brand: Universal Grip | Model: UGC-ST-400 | ● Configured to order
Designed for 45° compression-shear tests on wood-base panels, as in ASTM D1037, Fig. 31
100 kN (about 22,480 lbf) version with carriers and magnetic insert plates
Insert plates adapt the fixture to multiple panel thicknesses
10 kN (about 2,248 lbf) version in hardened, nickel-coated steel
Inclined loading blocks set the 45° shear plane
Suitable for particleboard, fiberboard and OSB
Standards: ASTM D1037
Trusted by Global Companies


























45° compression-shear fixture for wood-base panels
The UGC-ST-400 loads a panel specimen in combined compression and shear. The specimen is held between two loading blocks inclined at 45°, so the compressive load from the testing machine produces compression and shear in the panel at the same time. It is designed for the arrangement of ASTM D1037, Fig. 31 and is used on wood-base fiber and particle panel materials such as particleboard, fiberboard and OSB. Two versions are available: 100 kN (about 22,480 lbf) and 10 kN (about 2,248 lbf).
How the specimen is held and loaded
The fixture works in plain compression, so no grips are involved. The specimen sits between the inclined faces of the two loading blocks. As the crosshead pushes the blocks together, the inclined faces set the 45° shear plane through the panel and the machine records the load.
Panel thickness is the variable that changes from product to product. On the 100 kN version it is handled with carriers and insert plates: the carriers have magnets that hold the plates, and the plates are exchanged to accommodate specimens of multiple thicknesses without tools or a second fixture.
This page covers the hardware. See our complete ASTM D1037 guide for specimen preparation, procedure and calculations.
Versions
100 kN version: with carriers and magnetic insert plates for multiple panel thicknesses. Coupling and material are on request.
10 kN version: hardened, nickel-coated steel, with a female clevis coupling for a Ø 15.9 mm (5/8 in) pin.
Choose the capacity from the failure loads your panels reach. The 100 kN version, with its exchangeable insert plates, lets one fixture cover a product range with several thicknesses. The 10 kN version is the compact choice for lighter panels and smaller frames. If you are unsure, send us typical failure loads and thicknesses and we will recommend one.
The operating temperature range is on request for both versions. Dimensional drawings and 3D models are available on request.
Typical users
Particleboard and fiberboard
OSB and panel producers
Wood composite research
Building panel QC
Machine fit
The 100 kN version belongs on a Galdabini 100 kN benchtop universal testing machine or a floor-standing frame. The 10 kN version suits the 10 kN benchtop machine. Mounting is confirmed at quote, and adapters are available for other connections.
For tension perpendicular to the panel surface, see the UGC-ST-750 flatwise tensile adhesion fixture. Other shear hardware is on our shear fixtures page.
Tell us your panel thickness range, required capacity and machine coupling and we will configure the fixture: request a quote.
Product video
At a glance
Max. load: 100 kN (about 22,480 lbf) or 10 kN (about 2,248 lbf)
Test type: 45° compression-shear
Standard: ASTM D1037, Fig. 31
Specimen: Wood-base fiber and particle panels
Thickness adaptation: Carriers with magnetic insert plates (100 kN version)
Coupling (10 kN version): Female clevis, Ø 15.9 mm (5/8 in) pin
Wood Panel 45 Degree Compression-Shear Fixture Specifications
MAX. LOAD
100 kN (about 22,480 lbf) or 10 kN (about 2,248 lbf)
TEST TYPE
45° compression-shear
STANDARD
ASTM D1037, Fig. 31
SPECIMEN
Wood-base fiber and particle panels
THICKNESS ADAPTATION
Carriers with magnetic insert plates (100 kN version)
COUPLING (10 KN VERSION)
Female clevis, Ø 15.9 mm (5/8 in) pin
COUPLING (100 KN VERSION)
On request
MATERIAL (10 KN VERSION)
Steel, hardened, nickel-coated
MATERIAL (100 KN VERSION)
On request
TEMPERATURE RANGE
On request
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-400
Models & Options
100 kN version — With carriers and magnetic insert plates for multiple panel thicknesses (Specify at order)
10 kN version — Hardened, nickel-coated steel; female clevis for Ø 15.9 mm (5/8 in) pin (Specify at order)
Custom couplings and adapters — Connections for other machines (On request)
What's Included
45° compression-shear fixture with inclined loading blocks, in the capacity ordered
100 kN version: carriers and magnetic insert plates for multiple panel thicknesses
10 kN version: female clevis coupling for a Ø 15.9 mm (5/8 in) pin
Coupling for the 100 kN version is confirmed at quote
Supported Test Standards
ASTM D1037 — Properties of wood-base fiber and particle panel materials – compression-shear, Fig. 31
Compatible Grips & Fixtures
100 kN Benchtop Universal Testing Machine — Galdabini frame for the 100 kN version
10 kN Benchtop Universal Testing Machine — Galdabini frame for the 10 kN version
UGC-ST-750 Flatwise Tensile Adhesion Fixture — Tension perpendicular to the surface of wood-based panels
Shear Fixtures — Other fixtures for shear testing
Adapters — Couplings to connect the fixture to your machine
“Customer quote”
Related Equipment
UGC-ST-750 Flatwise Tensile Adhesion Fixture
Carrier-and-insert tensile fixture, rated 20 kN, for tension perpendicular to the surface of sandwich cores, panels, ins
UGC-ST-280 Bitumen Sheet Crack Bridging Fixture EN 14224
Two-part 10 kN frame with knurled jaws and guide rods that opens a simulated crack beneath a reinforced bitumen sheet, f
UGC-ST-650 Fire Sprinkler Strength Fixture EN 12259-1
Complete kit for hydraulic body strength tests on fire sprinklers up to 50 bar: four-column frame, three thread inserts,
UGC-ST-680 Drift Expanding Test Mandrel ISO 8493
Hardened 30° and 60° conical mandrels for drift expanding tests on metallic tubes, with cone diameters up to 130 mm and
Wood Panel 45 Degree Compression-Shear Fixture FAQ
What does the UGC-ST-400 do?
It holds a wood-base panel specimen between two loading blocks inclined at 45°, so a compressive load from the testing machine produces combined compression and shear in the panel.
Where can I find the test procedure?
This page covers the fixture. Our ASTM D1037 guide covers specimen preparation, procedure and calculations.
What capacities are available?
Two versions: 100 kN (about 22,480 lbf) and 10 kN (about 2,248 lbf).
How does it handle different panel thicknesses?
The 100 kN version uses carriers with magnets that hold exchangeable insert plates, which adapt the fixture to multiple panel thicknesses. Tell us your thickness range when you order.
What coupling and material does each version have?
The 10 kN version is hardened, nickel-coated steel with a female clevis for a Ø 15.9 mm (5/8 in) pin. Coupling and material for the 100 kN version are on request.
Which panel materials is it suitable for?
Wood-base fiber and particle panels, including particleboard, fiberboard and OSB.