Fiberglass Pipe Tensile Fixture – 50 to 85 kN
Tensile fixtures with diameter-matched carriers and inserts for longitudinal tests on fiberglass pipe and tube, 50 to 85 kN.
Brand: Universal Grip | Model: UGC-ST-710 | ● Configured to order
Designed for longitudinal tensile tests on fiberglass pipe and tube, such as ASTM D2105
Carriers and inserts matched to the pipe inner and outer diameters
Load is introduced without crushing the tube wall
Versions rated 50 kN, 55 kN and 85 kN (11,240 to 19,108 lbf)
Cryogenic 85 kN version for -196 to +15 °C (-321 to +59 °F)
Hardened, nickel-plated steel construction for high loads
Couplings from Ø 31.8 mm (1-1/4 in) to Ø 50 mm clevis, or M42 x 2 male thread
Standards: ASTM D2105
Trusted by Global Companies


























Tensile fixtures for fiberglass pipe and tube
The UGC-ST-710 is a family of special fixtures for determining the longitudinal tensile properties of fiberglass (glass-fiber-reinforced thermosetting-resin) pipe and tube, designed for tests such as ASTM D2105. Each fixture is made around the pipe it will test, so pipe producers, GRP pressure pipe qualification labs and composite tubing developers get hardware that fits their diameters instead of a general-purpose grip.
How the pipe is held and loaded
Each end of the pipe is mounted by hand on a hardened steel carrier fitted with inserts matched to the pipe's inner and outer diameters. The inserts support the pipe wall while the carriers pass the pull from the testing machine into the pipe, so the load is introduced without crushing the tube wall. Because the inserts are diameter-specific, each pipe size needs its own inserts; the 85 kN version, for example, comes as a carrier with two of them.
Versions
50 kN version (11,240 lbf): hardened steel, female clevis Ø 40 mm.
55 kN version (12,364 lbf): for tube ID 78.4 mm / OD 81.6 mm (3.09 / 3.21 in), female clevis Ø 31.8 mm (1-1/4 in), 0 to +70 °C (32 to 158 °F).
85 kN cryogenic version (19,108 lbf): carrier with two inserts for inner diameters 38–54 mm and 43–50 mm, -196 to +15 °C (-321 to +59 °F), female clevis Ø 31.8 mm.
Heavy coupling version: female clevis Ø 50 mm with 25 mm pin.
Threaded version: male thread M42 x 2 coupling.
These are examples of the range; the pipe size is matched per order. All versions are hardened, nickel-plated steel.
Typical applications
Fiberglass pipe and tube
GRP pressure pipe qualification
Composite tubing R&D
Cryogenic composite components
Machine fit
With ratings of 50 to 85 kN, these fixtures belong on a Galdabini 50 kN or 100 kN benchtop universal testing machine or a floor-standing frame, chosen by the breaking load of the pipe. Motorized force testers that stop at 1,500 lbf are too small. Standard connections are Ø 31.8 mm, Ø 40 mm or Ø 50 mm female clevis; other couplings are available on request or through adapters. For the cryogenic version, tell us how the specimen is cooled so the fixture can be matched to your setup.
This page covers the hardware. See our complete ASTM D2105 guide for specimen preparation, procedure and calculations. Dimensional drawings and 3D models are available on request. For a quote, send us the pipe inner and outer diameter, maximum load, test temperature and machine coupling: request a quote.
Product video
At a glance
Max. load: 50–85 kN depending on version (11,240–19,108 lbf)
Test type: Longitudinal tension, pipe and tube
Pipe size: Matched per order; e.g. ID 38–54 mm, ID 78.4 / OD 81.6 mm
Material: Steel, hardened, nickel-plated
Coupling: Female clevis Ø 31.8 mm (1-1/4 in), Ø 40 mm or Ø 50 mm; others on request
Temperature range: 0 to +70 °C; cryogenic version -196 to +15 °C
Fiberglass Pipe Tensile Fixture Specifications
MAX. LOAD
50–85 kN depending on version (11,240–19,108 lbf)
TEST TYPE
Longitudinal tension, pipe and tube
PIPE SIZE
Matched per order; e.g. ID 38–54 mm, ID 78.4 / OD 81.6 mm
MATERIAL
Steel, hardened, nickel-plated
COUPLING
Female clevis Ø 31.8 mm (1-1/4 in), Ø 40 mm or Ø 50 mm; others on request
TEMPERATURE RANGE
0 to +70 °C; cryogenic version -196 to +15 °C
OPERATION
Manual mounting of pipe ends on inserts
PART REF.
UGC-ST-710
Models & Options
50 kN version — Hardened steel, female clevis Ø 40 mm (Specify at order)
55 kN version — For tube ID 78.4 mm / OD 81.6 mm, female clevis Ø 31.8 mm, 0 to +70 °C (Specify at order)
85 kN cryogenic version — Carrier with 2 inserts for ID 38–54 mm and 43–50 mm, -196 to +15 °C, female clevis Ø 31.8 mm (Specify at order)
Heavy coupling version — Female clevis Ø 50 mm with 25 mm pin (Specify at order)
Threaded version — Male thread M42 x 2 coupling (Specify at order)
Other pipe sizes — Carriers and inserts matched to your pipe inner and outer diameter (On request)
What's Included
Pipe tensile fixture in the version ordered
Carriers and inserts matched to the pipe diameters specified at order
85 kN cryogenic version: carrier with 2 inserts (ID 38–54 mm and 43–50 mm)
Dimensional drawings and 3D models available on request
Supported Test Standards
ASTM D2105 — Longitudinal tensile properties of fiberglass pipe and tube
Compatible Grips & Fixtures
50 kN Benchtop Universal Testing Machine — Galdabini frame for the 50 kN version
100 kN Benchtop Universal Testing Machine — Galdabini frame for the 55 kN and 85 kN versions
Floor-Standing Universal Testing Machines — Higher-capacity frames with more test space for long pipe specimens
Adapters — For machine connections other than the standard clevis sizes
Tensile Testing — Grips, fixtures and machines for tensile tests
“Customer quote”
Related Equipment
UGC-ST-550 Celanese Compression Fixture EN 2850
Celanese-type compression fixture for fiber-reinforced plastic laminates, with 63 x 50 mm pyramid-serrated jaws and a -7
UGC-ST-840 Polymer Composite Compression Fixture GOST 33519
Bolt-clamped steel compression fixture for flat strip specimens of polymer composites, designed for GOST 33519 tests.
UGC-ST-540 Flatwise Tensile Bond Fixture EN 2243-4
Modular carriers and insert blocks for flatwise tensile and tensile adhesion tests on sandwich, foam and bonded specimen
UGC-ST-850 FRP Angle Break Strength Fixture
20 kN fixture that pulls FRP strengthening strips over a 30 mm roller, with lower wedge grips on universal joints to set
Fiberglass Pipe Tensile Fixture FAQ
How does the fixture hold the pipe?
Each pipe end is mounted by hand on a hardened steel carrier with inserts matched to the pipe's inner and outer diameters. This introduces the tensile load without crushing the tube wall.
What pipe sizes can it test?
The pipe size is matched per order. Existing examples include a version for tube ID 78.4 mm / OD 81.6 mm and a carrier with two inserts for inner diameters of 38–54 mm and 43–50 mm.
What load ratings are available?
Versions are rated 50 kN, 55 kN and 85 kN (11,240 to 19,108 lbf). Tell us the expected breaking load of your pipe and we will propose the version.
Is there a version for cryogenic tests?
Yes. The 85 kN cryogenic version is rated for -196 to +15 °C (-321 to +59 °F); the standard range is 0 to +70 °C.
Which machine couplings are offered?
Female clevis Ø 31.8 mm (1-1/4 in), Ø 40 mm or Ø 50 mm with 25 mm pin, and a male M42 x 2 thread. Other couplings are available on request or with adapters.
Where can I find the test procedure?
This page covers the hardware only. See our ASTM D2105 guide for specimen preparation, procedure and calculations.