top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Fiberglass Pipe Tensile Fixture

UGC-ST-710 fiberglass pipe tensile fixture with hardened steel carriers and diameter-matched inserts by Universal Grip
UGC-ST-710 fiberglass pipe tensile fixture with hardened steel carriers and diameter-matched inserts by Universal Grip
UGC-ST-710 Fiberglass Pipe Tensile Fixture by Universal Grip, view 2
UGC-ST-710 Fiberglass Pipe Tensile Fixture by Universal Grip, view 3
UGC-ST-710 Fiberglass Pipe Tensile Fixture by Universal Grip, view 4

Fiberglass Pipe Tensile Fixture – 50 to 85 kN

Tensile fixtures with diameter-matched carriers and inserts for longitudinal tests on fiberglass pipe and tube, 50 to 85 kN.

Brand: Universal Grip  |  Model: UGC-ST-710  |  ● Configured to order

  • Designed for longitudinal tensile tests on fiberglass pipe and tube, such as ASTM D2105

  • Carriers and inserts matched to the pipe inner and outer diameters

  • Load is introduced without crushing the tube wall

  • Versions rated 50 kN, 55 kN and 85 kN (11,240 to 19,108 lbf)

  • Cryogenic 85 kN version for -196 to +15 °C (-321 to +59 °F)

  • Hardened, nickel-plated steel construction for high loads

  • Couplings from Ø 31.8 mm (1-1/4 in) to Ø 50 mm clevis, or M42 x 2 male thread

Standards: ASTM D2105

Trusted by Global Companies

Tensile fixtures for fiberglass pipe and tube

The UGC-ST-710 is a family of special fixtures for determining the longitudinal tensile properties of fiberglass (glass-fiber-reinforced thermosetting-resin) pipe and tube, designed for tests such as ASTM D2105. Each fixture is made around the pipe it will test, so pipe producers, GRP pressure pipe qualification labs and composite tubing developers get hardware that fits their diameters instead of a general-purpose grip.

 

How the pipe is held and loaded

Each end of the pipe is mounted by hand on a hardened steel carrier fitted with inserts matched to the pipe's inner and outer diameters. The inserts support the pipe wall while the carriers pass the pull from the testing machine into the pipe, so the load is introduced without crushing the tube wall. Because the inserts are diameter-specific, each pipe size needs its own inserts; the 85 kN version, for example, comes as a carrier with two of them.

 

Versions

  • 50 kN version (11,240 lbf): hardened steel, female clevis Ø 40 mm.

  • 55 kN version (12,364 lbf): for tube ID 78.4 mm / OD 81.6 mm (3.09 / 3.21 in), female clevis Ø 31.8 mm (1-1/4 in), 0 to +70 °C (32 to 158 °F).

  • 85 kN cryogenic version (19,108 lbf): carrier with two inserts for inner diameters 38–54 mm and 43–50 mm, -196 to +15 °C (-321 to +59 °F), female clevis Ø 31.8 mm.

  • Heavy coupling version: female clevis Ø 50 mm with 25 mm pin.

  • Threaded version: male thread M42 x 2 coupling.

These are examples of the range; the pipe size is matched per order. All versions are hardened, nickel-plated steel.

 

Typical applications

  • Fiberglass pipe and tube

  • GRP pressure pipe qualification

  • Composite tubing R&D

  • Cryogenic composite components

 

Machine fit

With ratings of 50 to 85 kN, these fixtures belong on a Galdabini 50 kN or 100 kN benchtop universal testing machine or a floor-standing frame, chosen by the breaking load of the pipe. Motorized force testers that stop at 1,500 lbf are too small. Standard connections are Ø 31.8 mm, Ø 40 mm or Ø 50 mm female clevis; other couplings are available on request or through adapters. For the cryogenic version, tell us how the specimen is cooled so the fixture can be matched to your setup.

This page covers the hardware. See our complete ASTM D2105 guide for specimen preparation, procedure and calculations. Dimensional drawings and 3D models are available on request. For a quote, send us the pipe inner and outer diameter, maximum load, test temperature and machine coupling: request a quote.

Product video

At a glance

  • Max. load: 50–85 kN depending on version (11,240–19,108 lbf)

  • Test type: Longitudinal tension, pipe and tube

  • Pipe size: Matched per order; e.g. ID 38–54 mm, ID 78.4 / OD 81.6 mm

  • Material: Steel, hardened, nickel-plated

  • Coupling: Female clevis Ø 31.8 mm (1-1/4 in), Ø 40 mm or Ø 50 mm; others on request

  • Temperature range: 0 to +70 °C; cryogenic version -196 to +15 °C

Fiberglass Pipe Tensile Fixture Specifications

MAX. LOAD

50–85 kN depending on version (11,240–19,108 lbf)

 

TEST TYPE

Longitudinal tension, pipe and tube

 

PIPE SIZE

Matched per order; e.g. ID 38–54 mm, ID 78.4 / OD 81.6 mm

 

MATERIAL

Steel, hardened, nickel-plated

 

COUPLING

Female clevis Ø 31.8 mm (1-1/4 in), Ø 40 mm or Ø 50 mm; others on request

 

TEMPERATURE RANGE

0 to +70 °C; cryogenic version -196 to +15 °C

 

OPERATION

Manual mounting of pipe ends on inserts

 

PART REF.

UGC-ST-710

 

Models & Options

  • 50 kN version — Hardened steel, female clevis Ø 40 mm (Specify at order)

  • 55 kN version — For tube ID 78.4 mm / OD 81.6 mm, female clevis Ø 31.8 mm, 0 to +70 °C (Specify at order)

  • 85 kN cryogenic version — Carrier with 2 inserts for ID 38–54 mm and 43–50 mm, -196 to +15 °C, female clevis Ø 31.8 mm (Specify at order)

  • Heavy coupling version — Female clevis Ø 50 mm with 25 mm pin (Specify at order)

  • Threaded version — Male thread M42 x 2 coupling (Specify at order)

  • Other pipe sizes — Carriers and inserts matched to your pipe inner and outer diameter (On request)

What's Included

  • Pipe tensile fixture in the version ordered

  • Carriers and inserts matched to the pipe diameters specified at order

  • 85 kN cryogenic version: carrier with 2 inserts (ID 38–54 mm and 43–50 mm)

  • Dimensional drawings and 3D models available on request

Supported Test Standards

  • ASTM D2105 — Longitudinal tensile properties of fiberglass pipe and tube

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-550 Celanese Compression Fixture EN 2850

UGC-ST-550 Celanese Compression Fixture EN 2850

Celanese-type compression fixture for fiber-reinforced plastic laminates, with 63 x 50 mm pyramid-serrated jaws and a -7

UGC-ST-840 Polymer Composite Compression Fixture GOST 33519

UGC-ST-840 Polymer Composite Compression Fixture GOST 33519

Bolt-clamped steel compression fixture for flat strip specimens of polymer composites, designed for GOST 33519 tests.

UGC-ST-540 Flatwise Tensile Bond Fixture EN 2243-4

UGC-ST-540 Flatwise Tensile Bond Fixture EN 2243-4

Modular carriers and insert blocks for flatwise tensile and tensile adhesion tests on sandwich, foam and bonded specimen

UGC-ST-850 FRP Angle Break Strength Fixture

UGC-ST-850 FRP Angle Break Strength Fixture

20 kN fixture that pulls FRP strengthening strips over a 30 mm roller, with lower wedge grips on universal joints to set

Fiberglass Pipe Tensile Fixture FAQ

How does the fixture hold the pipe?

Each pipe end is mounted by hand on a hardened steel carrier with inserts matched to the pipe's inner and outer diameters. This introduces the tensile load without crushing the tube wall.

 

What pipe sizes can it test?

The pipe size is matched per order. Existing examples include a version for tube ID 78.4 mm / OD 81.6 mm and a carrier with two inserts for inner diameters of 38–54 mm and 43–50 mm.

 

What load ratings are available?

Versions are rated 50 kN, 55 kN and 85 kN (11,240 to 19,108 lbf). Tell us the expected breaking load of your pipe and we will propose the version.

 

Is there a version for cryogenic tests?

Yes. The 85 kN cryogenic version is rated for -196 to +15 °C (-321 to +59 °F); the standard range is 0 to +70 °C.

 

Which machine couplings are offered?

Female clevis Ø 31.8 mm (1-1/4 in), Ø 40 mm or Ø 50 mm with 25 mm pin, and a male M42 x 2 thread. Other couplings are available on request or with adapters.

 

Where can I find the test procedure?

This page covers the hardware only. See our ASTM D2105 guide for specimen preparation, procedure and calculations.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.