Celanese Compression Fixture EN 2850
Celanese-type compression fixture for fiber-reinforced plastic laminates, with 63 x 50 mm pyramid-serrated jaws and a -70 to +250 °C range.
Brand: Universal Grip | Model: UGC-ST-550 | ● Configured to order
Designed for Celanese compression tests such as EN 2850 Type A
Also used for ISO 14126 Method A and DIN 65380
Pyramid-serrated jaws, 63 x 50 mm (2.48 x 1.97 in), grip the specimen ends
Tapered collets load the specimen through shear at the gripped ends
Hardened, nickel-plated steel construction, 4.5 kg (9.9 lb)
Usable from -70 to +250 °C (-94 to +482 °F); other ranges on request
Sits between standard upper and lower compression platens
Standards: EN 2850 · ISO 14126 · DIN 65380 · ASTM D3410
Trusted by Global Companies


























Celanese compression fixture for fiber-reinforced plastic laminates
The UGC-ST-550 is a Celanese-type compression test fixture for fiber-reinforced plastic composites. It is designed for tests such as EN 2850 Type A, ISO 14126 Method A and DIN 65380, and is also listed for ASTM D3410. Aerospace qualification labs, laminate producers and composite research groups use it to load carbon and glass fiber laminates in compression through their gripped ends.
How the specimen is held and loaded
Tapered collets carry pyramid-serrated jaws measuring 63 x 50 mm (height x width, about 2.48 x 1.97 in). The jaws grip both ends of the specimen, and as the fixture is compressed the collets pass the load into the laminate through shear along the gripped faces. The fixture is not coupled to the testing machine. It stands between the upper and lower compression platens, which push its two halves together.
Construction and temperature range
The fixture is made of hardened, nickel-plated steel and weighs 4.5 kg (9.9 lb). Its standard working range is -70 to +250 °C (-94 to +482 °F), with other ranges on request, so one fixture serves room-temperature work and elevated-temperature compression tests in an environmental chamber. The maximum load is given on request: tell us the expected failure load of your strongest laminate and we will confirm it.
Platens and machine fit
One fixture is supplied. Compression platens are ordered separately if the machine does not already have a suitable pair; hardened steel platens of Ø 116 mm (4.57 in) are recommended. Because the fixture needs only platens, it can be used on a Galdabini universal testing machine with enough capacity and test space for the laminate. Frame capacity and platen mounting are confirmed at quote.
Typical applications
Aerospace composite qualification
Carbon and glass fiber laminates
Composite materials research
Elevated-temperature compression tests
Guides and related fixtures
This page describes the hardware. See our complete ISO 14126 guide and ASTM D3410 guide for specimen preparation, procedure and calculations. For open-hole compression of laminates at up to 100 kN, see the UGC-ST-260 composite laminate compression fixture.
Certified dimensional drawings and 3D models are available on request. Send us your test temperature, the expected maximum load and whether you need platens, and we will configure the fixture: request a quote.
Celanese Compression Fixture EN 2850 Specifications
TEST TYPE
Compression (shear-loaded)
STANDARDS
EN 2850 Type A, ISO 14126 Method A, DIN 65380
JAWS
63 x 50 mm (H x W), pyramid serrated
MATERIAL
Steel, hardened, nickel-plated
TEMPERATURE RANGE
-70 … +250 °C (-94 … +482 °F); other ranges on request
WEIGHT
4.5 kg (9.9 lb)
MAX. LOAD
On request
SCOPE OF SUPPLY
1 fixture; compression platens ordered separately
RECOMMENDED PLATENS
Ø 116 mm (4.57 in), hardened steel
PART REF.
UGC-ST-550
Models & Options
Celanese compression fixture — Standard version with 63 x 50 mm pyramid-serrated jaws, -70 to +250 °C (Specify at order)
Compression platens Ø 116 mm — Hardened steel upper and lower platens, recommended if not already available; ordered separately (Specify at order)
Other temperature ranges — Versions for temperatures outside -70 to +250 °C (On request)
What's Included
1 Celanese compression fixture with pyramid-serrated jaws, 63 x 50 mm
Compression platens are not included and are ordered separately
Ø 116 mm hardened steel platens are recommended if none are available
Certified drawings and 3D models available on request
Supported Test Standards
EN 2850 — Carbon fiber unidirectional laminates: compression test parallel to fiber direction (Type A)
ISO 14126 — Fiber-reinforced plastic composites: in-plane compressive properties (Method A)
DIN 65380 — Aerospace fiber-reinforced plastics: compression test on laminates
ASTM D3410 — Compressive properties of polymer matrix composites by shear loading
Compatible Grips & Fixtures
Compression Platens — Upper and lower platens the fixture stands between; Ø 116 mm hardened steel recommended
Environmental Chambers — Hot and cold compression tests within -70 to +250 °C
Universal Testing Machines — Galdabini frames; capacity confirmed against your laminate at quote
UGC-ST-260 Composite Laminate Compression Fixture — Open-hole compression of laminates, 100 kN
Compression Fixtures — Other compression test fixtures
“Customer quote”
Related Equipment
UGC-ST-260 Composite Laminate Compression Fixture
100 kN anti-buckling compression fixture with diamond-coated clamping surfaces for open-hole and bearing tests on compos
UGC-ST-840 Polymer Composite Compression Fixture GOST 33519
Bolt-clamped steel compression fixture for flat strip specimens of polymer composites, designed for GOST 33519 tests.
UGC-ST-540 Flatwise Tensile Bond Fixture EN 2243-4
Modular carriers and insert blocks for flatwise tensile and tensile adhesion tests on sandwich, foam and bonded specimen
UGC-ST-710 Fiberglass Pipe Tensile Fixture
Tensile fixtures with diameter-matched carriers and inserts for longitudinal tests on fiberglass pipe and tube, 50 to 85
Celanese Compression Fixture EN 2850 FAQ
How does the Celanese fixture load the specimen?
Tapered collets with pyramid-serrated 63 x 50 mm jaws grip the specimen ends. When the fixture is compressed, the load enters the laminate through shear at the gripped faces.
Does the fixture need a coupling to the testing machine?
No. It stands between the machine's upper and lower compression platens, which press the two halves together.
Are compression platens included?
No. One fixture is supplied and platens are ordered separately; hardened steel platens of Ø 116 mm are recommended if you do not already have a pair.
What temperature range does it cover?
-70 to +250 °C (-94 to +482 °F) as standard. Other ranges are available on request.
What is the maximum load?
The maximum load is given on request. Send us the expected failure load of your laminate and we will confirm the rating with the quote.
Where can I find the test procedure?
This page covers the hardware only. See our ISO 14126 guide and ASTM D3410 guide for specimen preparation, procedure and calculations.