top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Carpet Tuft Bind Fixture GOST 14217

UGC-ST-720 carpet tuft bind fixture with slotted specimen plate and upper hook by Universal Grip
UGC-ST-720 carpet tuft bind fixture with slotted specimen plate and upper hook by Universal Grip
UGC-ST-720 Carpet Tuft Bind Fixture GOST 14217 by Universal Grip, view 2
Product photo 3
Product photo 4

Carpet Tuft Bind Fixture GOST 14217

Tuft withdrawal fixture for carpets, designed for GOST 14217, with a slotted hold-down plate and a hook or pincer grip upper attachment.

Brand: Universal Grip  |  Model: UGC-ST-720  |  ● Configured to order

  • Slotted top plate holds the carpet flat while a single tuft is pulled out

  • Rigid box-frame lower holder keeps the specimen in place under the plate

  • Hook version for engaging loop tufts

  • Pincer grip version for clamping single tufts

  • Nickel-plated steel construction for corrosion resistance

  • Clevis pin connection to the testing machine; other sizes via adapters

  • Test arrangement designed for GOST 14217 tuft bind tests

Standards: GOST 14217

Trusted by Global Companies

Tuft withdrawal fixture for carpet tuft bind strength

The UGC-ST-720 is a fixture for determining the tuft bind strength of carpets, designed for GOST 14217. It answers a plain quality question: how much force does it take to pull one tuft out of the backing? Carpet manufacturers, floor covering laboratories and automotive carpet suppliers use it to check backing and coating processes and to compare one construction with another.

 

How it works

The carpet specimen is held under a slotted plate in a rigid lower box frame. The slot exposes the pile so a single tuft can be reached, while the plate on either side keeps the carpet flat during the pull. The upper attachment, a hook or a pincer grip, engages that one tuft, and the testing machine pulls it out in tension. The peak force needed to withdraw the tuft is recorded.

Holding the specimen flat is the point of the design. If the carpet were free to lift with the tuft, some of the crosshead travel would go into doming the backing and the tuft would no longer be drawn straight out. With the slotted plate in place, each tuft is pulled against the same support.

 

Hook or pincer grip

  • Hook version: an upper hook for engaging loop tufts. It is the usual choice for loop-pile carpet, where the hook can pass through the loop.

  • Pincer grip version: an upper pincer grip for clamping single tufts. It is the usual choice for cut pile, where there is no loop to hook.

If you test both pile types, say so when you ask for a quote and we will price the attachments together.

 

Construction and mounting

The fixture is made of nickel-plated steel for corrosion resistance and is used at ambient temperature. It connects to the testing machine through a clevis pin coupling, and other coupling sizes are handled with adapters. The maximum load is on request: it is confirmed with the configuration, so tell us the tuft forces you expect. The fixture is used on an electromechanical frame such as a Galdabini benchtop universal testing machine, and we confirm the coupling and load cell range for your machine at quote.

 

Typical applications

  • Tufted carpets

  • Carpet tiles

  • Textile floor coverings

  • Automotive carpets

For other carpet tests, see the UGC-ST-740 carpet and textile rigidity fixture and the UGC-ST-890 carpet button pull-out fixture.

Tell us whether you need the hook or the pincer grip version, your carpet thickness and your machine coupling, and we will configure the fixture. Dimensional drawings and 3D models are available on request. Request a quote.

Product video

At a glance

  • Test type: Tuft withdrawal, tension

  • Upper attachment: Hook or pincer grip

  • Lower holder: Box frame with slotted specimen plate

  • Material: Steel, nickel-plated

  • Max. load: On request

  • Coupling: Clevis pin coupling; other sizes via adapters

Carpet Tuft Bind Fixture GOST 14217 Specifications

TEST TYPE

Tuft withdrawal, tension

 

UPPER ATTACHMENT

Hook or pincer grip

 

LOWER HOLDER

Box frame with slotted specimen plate

 

MATERIAL

Steel, nickel-plated

 

MAX. LOAD

On request

 

COUPLING

Clevis pin coupling; other sizes via adapters

 

TEMPERATURE RANGE

Ambient

 

SPECIMENS

Tufted carpets, carpet tiles, textile floor coverings, automotive carpets

 

STANDARDS NAMED

GOST 14217

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-ST-720

 

Models & Options

  • Hook version — Upper hook for engaging loop tufts (Specify at order)

  • Pincer grip version — Upper pincer grip for clamping single tufts (Specify at order)

  • Coupling adapters — Other clevis sizes and machine connections (On request)

What's Included

  • Lower box frame with slotted specimen plate

  • Upper attachment in the version ordered: hook or pincer grip

  • Clevis pin coupling to the testing machine

  • Exact scope of supply is confirmed on the quote

  • Dimensional drawings and 3D models available on request

Supported Test Standards

  • GOST 14217 — Tuft bind (tuft withdrawal) strength of carpets

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-740 Carpet and Textile Rigidity Fixture

UGC-ST-740 Carpet and Textile Rigidity Fixture

Wedge-indenter fixture that pushes a clamped carpet or textile specimen into a slot to measure its rigidity, for automot

UGC-ST-890 Carpet Button Pull-Out Fixture

UGC-ST-890 Carpet Button Pull-Out Fixture

1 kN fixture for the pull-out strength of plastic retaining buttons in carpet, with a toggle-clamped base plate and thre

UGC-ST-690 Fabric Bending Stiffness Fixture

UGC-ST-690 Fabric Bending Stiffness Fixture

Bench-top cantilever fixture for the bending stiffness of nonwovens and textile fabrics, with a sample opening adjustabl

UGC-ST-730 Textile Tear Strength Fixture UNE 40413

UGC-ST-730 Textile Tear Strength Fixture UNE 40413

Tear strength fixture for textile fabrics, designed for UNE 40413, with a serrated-jaw upper grip in a rigid U-frame and

Carpet Tuft Bind Fixture GOST 14217 FAQ

What does the UGC-ST-720 measure?

The peak force needed to withdraw a single tuft from a carpet specimen, known as tuft bind strength. The test arrangement is designed for GOST 14217.

 

Should I order the hook or the pincer grip version?

The hook engages loop tufts, so it is the usual choice for loop-pile carpet. The pincer grip clamps single tufts and is the usual choice for cut pile.

 

How is the carpet held during the test?

Under a slotted plate in a rigid lower box frame. The plate holds the carpet flat while the tuft is pulled out through the slot.

 

What is the maximum load?

It is on request and is confirmed with the configuration. Tell us the tuft forces you expect when you ask for a quote.

 

How does it mount on my testing machine?

With a clevis pin coupling. Other sizes are available through our adapters; send us your machine model and coupling dimensions.

 

What information do you need to quote it?

Hook or pincer grip version, carpet thickness and machine coupling. Contact us with those details.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page