Home › Products › Standard-Specific Test Fixtures › Fabric Bending Stiffness Fixture





Fabric Bending Stiffness Fixture – Cantilever Method
Bench-top cantilever fixture for the bending stiffness of nonwovens and textile fabrics, with a sample opening adjustable from 2 to 12 mm.
Brand: Universal Grip | Model: UGC-ST-690 | ● Configured to order
Cantilever principle: the fabric strip bends under its own weight
Sample opening adjustable from 2 to 12 mm (about 0.08 to 0.47 in)
Accommodates thick needle-punched nonwovens and felts
Anodized aluminum construction, 700 x 200 x 336 mm (L x W x H)
Bench-top use: no load cell and no machine coupling required
Used for cantilever tests such as DIN 53362, EN ISO 9073-7, ASTM D1388 and ASTM D5732
Standards: ASTM D1388 · DIN 53362 · EN ISO 9073-7 · ASTM D5732
Trusted by Global Companies


























Bench-top cantilever fixture for fabric bending stiffness
The UGC-ST-690 is a stand-alone fixture for determining the bending stiffness of fabrics by the cantilever method. It was laid out with bulky materials in mind, needle-punched nonwovens and felts in particular, and it also handles woven and knitted fabrics, geotextile fabrics and other technical textiles. Nonwoven producers, textile mills and R&D labs use it when they want a stiffness figure without tying up a testing machine.
How the fixture works
A fabric strip is advanced over the edge of a horizontal platform. As the overhang grows, the strip bends under its own weight, and the overhang length at a defined deflection is the reading from which bending length and flexural rigidity are derived. Gravity supplies the bending force. There is no load cell, no crosshead and no coupling to think about: the fixture sits on the bench and is ready to use.
What sets this model apart is its adjustable sample opening. It can be set anywhere from 2 to 12 mm (about 0.08 to 0.47 in), so the same frame takes a thin woven strip and a thick needle-punched felt.
Construction and size
Frame: anodized aluminum.
Overall size: 700 x 200 x 336 mm (L x W x H), roughly 27.6 x 7.9 x 13.2 in.
Sample opening: 2–12 mm, adjustable.
Bending force: gravity, from the specimen's own weight.
Machine fit: none needed. A maximum load does not apply and no coupling is required.
Typical applications and standards
Typical specimens are needle-punched nonwovens, woven and knitted fabrics, geotextile fabrics and development samples of technical textiles. The fixture is used for cantilever stiffness tests such as DIN 53362, EN ISO 9073-7, ASTM D1388 and ASTM D5732. See our complete ASTM D1388 guide for specimen preparation, procedure and calculations; this page covers the hardware only.
If your lab also measures the strength, tear or seam performance of the same fabrics on a testing machine, our textile testing grips and fixtures cover those tests, and other single-purpose fixtures are listed with our standard-specific test fixtures.
Ordering
Tell us the thickness range of your specimens and the standard you plan to follow, and we will confirm the configuration. Dimensional drawings are shown on the data sheet, and certified drawings and 3D models are available on request. Request a quote.
Fabric Bending Stiffness Fixture Specifications
TEST TYPE
Bending stiffness, cantilever method
BENDING FORCE
Gravity (specimen self-weight)
SAMPLE OPENING
2–12 mm (about 0.08–0.47 in), adjustable
DIMENSIONS
700 x 200 x 336 mm (L x W x H)
MATERIAL
Aluminum, anodized
MAX. LOAD
Not applicable
COUPLING
Not required (bench-top)
SPECIMENS
Needle-punched nonwovens, woven and knitted fabrics, geotextile fabrics
STANDARDS NAMED
DIN 53362, EN ISO 9073-7, ASTM D1388, ASTM D5732
DRAWINGS
Dimensional drawings on the data sheet; certified drawings and 3D models on request
PART REF.
UGC-ST-690
Models & Options
Standard fixture — Cantilever bending stiffness fixture with 2–12 mm adjustable sample opening (Specify at order)
Standard to be followed — Tell us which cantilever method you run so the configuration can be confirmed (Specify at order)
Custom versions — Other sizes or configurations for unusual specimens (On request)
What's Included
1 bench-top cantilever bending stiffness fixture
Anodized aluminum frame with sample opening adjustable from 2 to 12 mm
No load cell, grips or machine coupling are needed
Certified dimensional drawings and 3D models available on request
Supported Test Standards
ASTM D1388 — Stiffness of fabrics
DIN 53362 — Bending stiffness by the cantilever method
EN ISO 9073-7 — Nonwovens: determination of bending length
ASTM D5732 — Stiffness of nonwoven fabrics using the cantilever test
Compatible Grips & Fixtures
Textiles — Grips and fixtures for fabric and nonwoven testing
UGC-ST-740 Carpet and Textile Rigidity Fixture — Wedge-indenter rigidity fixture for a testing machine
UGC-ST-070 Tire Cord Fabric Stiffness Fixture — Stiffness fixture for tire cord fabric
Standard-Specific Test Fixtures — Other single-test fixtures
Bend Testing — Overview of bend and flexure test methods
“Customer quote”
Related Equipment
UGC-ST-740 Carpet and Textile Rigidity Fixture
Wedge-indenter fixture that pushes a clamped carpet or textile specimen into a slot to measure its rigidity, for automot
UGC-ST-070 Tire Cord Fabric Stiffness Fixture
Low-force wire-frame fixture, rated for 10 N, for stiffness tests on tire cords and cord fabrics as arranged in ASTM D88
UGC-ST-630 Needle Tear Seam Strength Fixture ISO 17697
Needle tear fixture for the seam strength of footwear uppers, linings and insocks, used for ISO 17697 and EN 13572 Metho
UGC-ST-720 Carpet Tuft Bind Fixture GOST 14217
Tuft withdrawal fixture for carpets, designed for GOST 14217, with a slotted hold-down plate and a hook or pincer grip u
Fabric Bending Stiffness Fixture FAQ
Does the UGC-ST-690 need a testing machine or load cell?
No. The specimen bends under its own weight, so the fixture is used on the bench with no load cell and no machine coupling.
What specimen thickness can it take?
The sample opening adjusts from 2 to 12 mm (about 0.08 to 0.47 in). That covers thin fabrics through thick needle-punched nonwovens and felts.
Which tests is it used for?
Cantilever stiffness tests such as DIN 53362, EN ISO 9073-7, ASTM D1388 and ASTM D5732. Our ASTM D1388 guide covers specimen preparation, procedure and calculations.
How large is the fixture?
700 x 200 x 336 mm (L x W x H), roughly 27.6 x 7.9 x 13.2 in. The frame is anodized aluminum.
What materials is it suited to?
Needle-punched nonwovens, woven and knitted fabrics, geotextile fabrics and technical textiles in development.
What do you need from me to quote it?
Your specimen thickness range and the standard you intend to follow. Contact us and we will confirm the configuration.