Home › Products › Shoulder and Button Head Grips › Spherically Seated Shoulder Grip Carrier 60 mm





Spherically Seated Shoulder Grip Carrier 60 mm – 300 kN
300 kN side-loading carrier with a self-aligning spherical seat and interchangeable inserts for button-head, threaded and screw-head specimens.
Brand: Universal Grip | Model: UGC-SH-310 | ● Configured to order
Spherical seat aligns the specimen with the load axis and limits bending
Open side: specimen and insert load without removing the carrier
Inserts for button-head, threaded-end and screw-head specimens
Split two-piece inserts for button-head specimens up to Ø 20 mm
Hardened, nickel-coated steel carrier rated to 300 kN (about 67,400 lbf)
Female clevis Ø 60 mm; pair supplied with retaining pin and ring
Standards: ASTM E8 · ISO 6892-1 · ISO 898-1
Trusted by Global Companies


























Spherically seated carrier for shoulder and threaded specimens
The UGC-SH-310 is a heavy-duty carrier for tensile tests on button-head, threaded and screw-head specimens up to 300 kN. Its spherical seat makes it the choice for labs that need low bending on short, stiff or brittle specimens, such as metals labs qualifying high-strength alloys, fastener suppliers and carbon and graphite producers.
How it works
The carrier body is open on one side. An insert sized to the specimen drops into a spherical seat inside the body, and the specimen head or thread sits in the insert. As load is applied, the seat lets the insert rotate slightly so the specimen lines up with the load axis, reducing the bending stresses that would otherwise lower measured strength or cause premature failure at the fillet. A retaining pin and ring secure the carrier to the machine.
Inserts
Button-head inserts: split in two, made to specimen diameter (up to 20 mm) and fillet radius.
Threaded-end inserts: one piece, made to the specimen thread.
Screw-head inserts: made to the screw diameter.
Insert size limits the usable load as well as the carrier. For example, an insert for Ø 12.7 mm (0.5 in) specimens with a 9.53 mm radius is rated to 180 kN, and one for Ø 6.35 mm (0.25 in) specimens with a 4.78 mm radius to 50 kN. Carriers and inserts are ordered separately.
Typical applications
Metals tensile testing with button-head or threaded specimens in tests such as ASTM E8 and ISO 6892-1, bolts and screws (see our ISO 898-1 guide), and carbon and graphite specimens, where the spherical seat helps protect brittle material from bending. For a dedicated carbon and graphite setup, see UGC-SH-140.
Machine fit
At 300 kN the carrier belongs on a floor-standing or hydraulic universal testing machine; Galdabini frames run up to 2,000 kN. The Ø 60 mm female clevis can be matched to other load strings with adapters. Rated temperature is 0 to 70 °C. If you do not need a spherical seat, the UGC-SH-220 button head grips cover 50 to 1000 kN.
Send the specimen type, diameter and fillet radius or thread, and your machine coupling, and we will specify carriers and inserts.
Spherically Seated Shoulder Grip Carrier 60 mm Specifications
MAX. LOAD
300 kN
TEST TYPE
Tensile test of shoulder-head and threaded specimens
SPECIMEN DIAMETER
Up to Ø 20 mm (button-head inserts)
SEAT
Spherical, self-aligning
COUPLING
Female clevis, Ø 60 mm; others on request
MATERIAL
Steel, hardened, nickel-coated
TEMPERATURE RANGE
0 to 70 °C
WEIGHT
4.5 kg per carrier
SCOPE OF DELIVERY
1 pair of carriers incl. pin and ring; inserts ordered separately
PART REF.
UGC-SH-310
Models & Options
Name — Description (Part #)
Carrier, 300 kN — Female clevis Ø 60 mm, pair, with pin and ring (Specify at order)
Button-head inserts — Split, sized by specimen diameter (max. 20 mm) and fillet radius (Specify at order)
Threaded-end inserts — One-piece, sized by thread (Specify at order)
Screw-head inserts — Sized by screw diameter (Specify at order)
Example insert Ø 12.7 mm, R 9.53 mm — Max. 180 kN (On request)
Example insert Ø 6.35 mm, R 4.78 mm — Max. 50 kN (On request)
What's Included
One pair of spherically seated carriers
Retaining pin and ring
Inserts are ordered separately for each specimen type and size
Supported Test Standards
ASTM E8 — Tension testing of metallic materials
ISO 6892-1 — Metallic materials – tensile testing at room temperature
ISO 898-1 — Mechanical properties of carbon and alloy steel bolts, screws and studs
Compatible Grips & Fixtures
Floor-standing testing machines — Frames for the 300 kN rating
Hydraulic testing machines — High-capacity metals testing
Button Head Grips with Split Inserts — Non-spherical carriers, 50–1000 kN
Carbon and Graphite Tensile Fixture — Dedicated fixture for carbon and graphite
Adapters — Match the Ø 60 mm clevis to your load string
“Customer quote”
Related Equipment
UGC-SH-140 Carbon and Graphite Tensile Fixture
Carrier and insert set that seats shaped carbon and graphite specimens for tensile stress-strain tests to ASTM C749, in
UGC-SH-220 Button Head Grips with Split Inserts
Carrier grips with two-piece inserts that close around the shank and seat the head of button-head and shoulder-end round
UGC-SH-300 Building Sealant Tensile Fixture ISO 8339
Side-loading chuck grips for H-shaped sealant joint specimens in ISO 8339 tensile tests, with fixed 5 kN and adjustable
UGC-SH-320 Coating Bond Strength Tensile Fixture ISO 4624
Self-aligning pull-off fixture with interchangeable test cylinders for tensile adhesion of paints, coatings and thermal
Spherically Seated Shoulder Grip Carrier 60 mm FAQ
Why use a spherically seated carrier?
The spherical seat lets the insert self-align so the specimen is loaded along its axis. This reduces bending, which matters most for short, stiff or brittle specimens.
What specimen types can it hold?
Button-head specimens up to Ø 20 mm with split inserts, threaded-end specimens with one-piece inserts, and screws with screw-head inserts.
Is the full 300 kN available with every insert?
No. Small inserts carry less: for example, a Ø 12.7 mm R 9.53 mm insert is rated to 180 kN and a Ø 6.35 mm R 4.78 mm insert to 50 kN.
Are inserts included?
No. The carriers are supplied as a pair with retaining pin and ring; inserts are ordered for each specimen geometry.
Can I use it for bolt testing?
Yes, screw-head and threaded-end inserts suit bolts and screws in tests such as those described in our ISO 898-1 guide.
What machine do I need?
A floor-standing or hydraulic testing machine with a Ø 60 mm clevis, or an adapter to your coupling.