top of page

Home  ›  Products  ›  Shoulder and Button Head Grips  ›  Heavy Duty Specimen Holder 100 kN

UGC-SH-370 heavy duty 100 kN specimen holder with spherical seat and 0.75 in insert by Universal Grip
UGC-SH-370 heavy duty 100 kN specimen holder with spherical seat and 0.75 in insert by Universal Grip
UGC-SH-370 Heavy Duty Specimen Holder 100 kN by Universal Grip, view 2
UGC-SH-370 Heavy Duty Specimen Holder 100 kN by Universal Grip, view 3
Product photo 4

Heavy Duty Specimen Holder 100 kN – Inch-Size Inserts

Spherically seated 100 kN holder with thumb-screw-retained inserts for 0.75 in and 0.5 in shouldered round tensile specimens.

Brand: Universal Grip  |  Model: UGC-SH-370  |  ● Configured to order

  • Rated to 100 kN (about 22,480 lbf)

  • Spherical seat with ring nut aligns the specimen with the load axis

  • Interchangeable inserts for 0.75 in (19.05 mm) and 0.5 in (12.7 mm) specimens

  • Knurled thumb screw retains the insert without tools

  • Hardened, nickel-coated steel for wear and corrosion resistance

  • Male clevis Ø 50 mm with Ø 17.5 mm pin hole

Standards: ASTM E8  ·  ASTM A370

Trusted by Global Companies

100 kN holder for inch-size shouldered round specimens

The UGC-SH-370 is a compact, heavy-duty holder for tensile tests on shouldered round specimens made to inch dimensions. Steel and alloy labs that machine 0.5 in and 0.75 in specimens use it to get repeatable alignment without the setup time of a wedge grip, and without marking the specimen shoulders.

 

How it works

The specimen passes through an insert sized to its shank, and its shoulder bears on the insert face. A knurled thumb screw holds the insert in the holder. Between the holder and its coupling is a spherical seat locked by a ring nut; as load comes on, the seat lets the holder settle onto the load axis, which limits bending in the specimen gauge length.

 

Inserts

  • 0.75 in insert: for 0.75 in (19.05 mm) specimens.

  • 0.5 in insert: for 0.5 in (12.7 mm) specimens.

Swapping inserts means loosening the thumb screw, lifting one out and dropping in the other. Further sizes can be discussed if your specimen drawings use other diameters.

 

Construction

Holder and inserts are hardened, nickel-coated steel, so seating faces resist wear from repeated specimen changes and the parts stay clean in a busy metals lab. Because the insert, not the holder, sets the specimen size, one holder serves both common inch diameters, and a worn insert can be replaced on its own. The holder connects with a male clevis, Ø 50 mm, with a Ø 17.5 mm pin hole.

 

Typical applications

Metals tensile testing on inch-size round specimens in tests such as ASTM E8 and ASTM A370, heavy-duty material qualification, and steel and alloy laboratories. For metric specimens or larger loads, compare the quick-change UGC-SH-350 and the UGC-SH-310 carriers.

 

Machine fit

A 100 kN benchtop testing machine matches the holder rating, and floor-standing machines give extra headroom; Galdabini universal testing machines from 2.5 kN to 2,000 kN are available for either role. Adapters connect the male clevis to crossheads with other pins or threads.

Tell us the specimen diameter, head geometry and the inserts you need, along with your machine coupling, and we will quote the holder.

Product video

At a glance

  • Max. load: 100 kN

  • Test type: Tensile test of shouldered round specimens

  • Inserts: For 0.75 in and 0.5 in specimens

  • Seat: Spherical, self-aligning

  • Material: Steel, hardened, nickel-coated

  • Coupling: Male clevis, Ø 50 mm with Ø 17.5 mm pin hole

Heavy Duty Specimen Holder 100 kN Specifications

MAX. LOAD

100 kN

 

TEST TYPE

Tensile test of shouldered round specimens

 

INSERTS

For 0.75 in and 0.5 in specimens

 

SEAT

Spherical, self-aligning

 

MATERIAL

Steel, hardened, nickel-coated

 

COUPLING

Male clevis, Ø 50 mm with Ø 17.5 mm pin hole

 

OPERATION

Manual, thumb screw retention

 

PART REF.

UGC-SH-370

 

Models & Options

  • Name — Description (Part #)

  • Insert 0.75 in — For 0.75 in (19.05 mm) specimens (Specify at order)

  • Insert 0.5 in — For 0.5 in (12.7 mm) specimens (Specify at order)

  • Other insert sizes — For other specimen diameters (On request)

What's Included

  • Holder with spherical seat, ring nut and knurled thumb screw

  • Inserts for 0.75 in and/or 0.5 in specimens as specified

  • Quantity (single holder or pair) confirmed with your quote

Supported Test Standards

  • ASTM E8 — Tension testing of metallic materials

  • ASTM A370 — Mechanical testing of steel products

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SH-310 Spherically Seated Shoulder Grip Carrier 60 mm

UGC-SH-310 Spherically Seated Shoulder Grip Carrier 60 mm

300 kN side-loading carrier with a self-aligning spherical seat and interchangeable inserts for button-head, threaded an

UGC-SH-350 Shoulder Grip with Quick-Change Inserts 70 mm

UGC-SH-350 Shoulder Grip with Quick-Change Inserts 70 mm

250 kN hardened carrier with drop-in inserts for button-head, threaded-end and screw-head round metallic specimens; chan

UGC-SH-360 Nail Withdrawal Resistance Fixture

UGC-SH-360 Nail Withdrawal Resistance Fixture

Upper grip with adjustable 3–30 mm sample gap and 1.75 mm radius nail slot for direct nail withdrawal tests on wood-base

UGC-SH-340 Adhesive Bond Tensile Fixture GOST 14760

UGC-SH-340 Adhesive Bond Tensile Fixture GOST 14760

Pair of bond-strength fixtures hung from universal joint adapters, so a bonded insert joint is pulled in pure tension to

Heavy Duty Specimen Holder 100 kN FAQ

What specimens does the UGC-SH-370 hold?

Shouldered round tensile specimens; inserts are available for 0.75 in (19.05 mm) and 0.5 in (12.7 mm) specimens.

 

How does the spherical seat help?

It lets the holder settle onto the load axis as force builds, limiting bending in the gauge length. A ring nut locks the seat.

 

How are inserts changed?

Loosen the knurled thumb screw, lift the insert out and drop in the other size. No tools are needed.

 

What is the load rating?

The holder is rated to 100 kN, about 22,480 lbf.

 

What coupling does it use?

A male clevis, Ø 50 mm, with a Ø 17.5 mm pin hole. Other connections use adapters.

 

Which standards is it suited to?

Inch-size round specimens in tests such as ASTM E8 and ASTM A370.

 

Need help configuring a shoulder and button head grip?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page