Home › Products › Standard-Specific Test Fixtures › Adhesion and Shear Test Fixture OST





Adhesion and Shear Test Fixture OST – Heat-Shielding Plastics
Nickel-coated steel fixtures for adhesion tests to OST 1-90016 and layer shear tests to OST 92-1472 Method B on heat-shielding and structural plastics.
Brand: Universal Grip | Model: UGC-ST-020 | ● Configured to order
Adhesion test fixture designed for OST 1-90016
Layer shear fixture designed for OST 92-1472 Method B
Two adjustable supports on a graduated beam for setting the span
Universal joints let the load train align itself
Slotted lower holder for quick specimen change
Nickel-coated steel construction for corrosion resistance
Male clevis coupling with Ø 31.7 mm (1-1/4 in) pin hole
Standards: OST 1-90016 · OST 92-1472
Trusted by Global Companies


























Adhesion and Layer Shear Fixtures for Heat-Shielding and Structural Plastics
The UGC-ST-020 covers two related fixtures for heat-shielding and structural plastic materials tested to the OST industry standards: an adhesion test fixture designed for OST 1-90016 and a layer shear fixture designed for OST 92-1472 Method B. Both are made of nickel-coated steel and hang in the load train of a universal testing machine. They are aimed at aerospace materials labs and at suppliers of laminates and coatings who report results against these specifications.
How it works
The upper part of the fixture is a beam carrying two adjustable supports. The supports are positioned against a graduated scale, so the span can be set, read directly and returned to the same value for the next series. The beam hangs from a universal joint, which lets the assembly align itself under load instead of forcing a side load into the specimen. The lower part holds the loading element in a slotted holder, and the slot makes specimen changes quick between tests.
The nickel coating protects the steel against corrosion in storage and in day-to-day handling, which helps the scale and the adjustable supports stay clean and readable.
Versions
Adhesion fixture: designed for adhesion tests to OST 1-90016
Layer shear fixture: designed for the layer shear test of OST 92-1472 Method B
These are two separate fixtures. State which test you run, or order both. Maximum load and temperature range are on request and are set against your specimen and test conditions when we quote. If your specimens differ from the usual sizes, send a drawing or the dimensions so the supports and holder can be checked against them.
Typical applications
Heat-shielding materials
Structural plastics
Laminates and coatings
Aerospace materials
Machine fit and coupling
Each fixture connects through a male clevis with a Ø 31.7 mm (1-1/4 in) pin hole, which pins into a matching female clevis in the load train. The fixtures can be set up on Galdabini universal testing machines; because the load rating is on request, we match the fixture and the frame capacity to your test at quote. Adapters are available for other couplings.
For other interlaminar and bond-line tests, see our shear fixtures, and for tensile and flexural work on the same materials see the plastics testing page. More single-purpose setups are listed under standard-specific test fixtures.
Tell us which test you need (adhesion or layer shear), your specimen dimensions and your machine coupling, and we'll configure the fixture. Request a quote or call 978-882-1480.
Adhesion and Shear Test Fixture OST Specifications
TEST TYPE
Adhesion and layer shear
SUPPORT SPAN
Adjustable on graduated scale
ALIGNMENT
Universal joints
COUPLING
Male clevis, Ø 31.7 mm (1-1/4 in) pin hole
MATERIAL
Steel, nickel-coated
MAX. LOAD
On request
TEMPERATURE RANGE
On request
STANDARDS
OST 1-90016, OST 92-1472
PART REF.
UGC-ST-020
Models & Options
Adhesion fixture — Fixture for adhesion tests, designed for OST 1-90016; nickel-coated steel (Specify at order)
Layer shear fixture — Fixture for layer shear tests, designed for OST 92-1472 Method B; nickel-coated steel (Specify at order)
Coupling adapters — Adapters from the Ø 31.7 mm (1-1/4 in) male clevis to other machine couplings (On request)
Custom version — Other spans, load ratings or temperature ranges (On request)
What's Included
Adhesion fixture or layer shear fixture, as ordered (two separate fixtures)
Universal joint for self-alignment of the load train
Male clevis coupling with Ø 31.7 mm (1-1/4 in) pin hole
Dimensional drawings or 3D models on request; full scope of supply is confirmed at quote
Supported Test Standards
OST 1-90016 — Adhesion testing of heat-shielding and structural plastic materials
OST 92-1472 — Layer shear test, Method B
Compatible Grips & Fixtures
Universal Testing Machines — Galdabini frames; capacity matched to the fixture at quote
Adapters — Couplings between the 1-1/4 in clevis and other load trains
Shear Fixtures — Other shear test fixtures for laminates and bonded joints
Plastics Testing — Grips and fixtures for plastic materials
Standard-Specific Test Fixtures — Other fixtures made for one named test
“Customer quote”
Related Equipment
UGC-ST-010 Metallic Coating Bend Fixture
Bench-mounted, hand-crank bend fixture for qualitative adhesion checks on metallic coatings, designed for bend tests suc
UGC-ST-030 Adhesion Test Centering Device ISO 4624
Multi-position aluminum centering device that holds pull-off test cylinders coaxial with the specimen while the adhesive
UGC-ST-850 FRP Angle Break Strength Fixture
20 kN fixture that pulls FRP strengthening strips over a 30 mm roller, with lower wedge grips on universal joints to set
UGC-ST-430 Aluminum Adhesive Bond Wedge Fixture
Machine-driven wedge fixture, rated to 30 kN, for adhesive bond durability wedge tests on aluminum joints such as ASTM D
Adhesion and Shear Test Fixture OST FAQ
What tests does the UGC-ST-020 cover?
Adhesion tests to OST 1-90016 and layer shear tests to OST 92-1472 Method B, on heat-shielding and structural plastic materials.
Is it one fixture or two?
Two. The adhesion fixture and the layer shear fixture are separate versions, so specify which test you run or order both.
What is the maximum load?
Maximum load is on request. Send us your expected failure loads and specimen dimensions and we will confirm the rating with the quote.
How does it connect to the testing machine?
Through a male clevis with a Ø 31.7 mm (1-1/4 in) pin hole. Other couplings are handled with adapters.
How is alignment maintained?
The beam hangs from a universal joint, so the load train aligns itself as load is applied. This keeps side loads out of the specimen.
How is the support span set?
The two supports are adjustable along a beam with a graduated scale, so the span is set and read directly on the fixture.
Can it be used at elevated temperature?
The temperature range is on request. Tell us your test temperature and we will confirm suitability before you order.