Home › Products › Standard-Specific Test Fixtures › Adhesion Test Centering Device ISO 4624





Adhesion Test Centering Device ISO 4624
Multi-position aluminum centering device that holds pull-off test cylinders coaxial with the specimen while the adhesive cures.
Brand: Universal Grip | Model: UGC-ST-030 | ● Configured to order
Holds pull-off test cylinders coaxial with the specimen while the adhesive cures
Follows the centering arrangement shown in ISO 4624 Figure 3
Two aligned bars with matching bores, Ø 20 mm, height 40 mm
Several test assemblies can be prepared at once; number of positions on request
Wing nuts clamp the bars by hand, without tools
Lightweight aluminum construction for easy handling at the bench
Standards: ISO 4624
Trusted by Global Companies


























Multi-Position Centering Device for Pull-Off Adhesion Test Assemblies
The UGC-ST-030 is a specimen preparation aid, not a grip. It holds pull-off test cylinders coaxially with the specimen while the adhesive cures, following the centering arrangement shown in ISO 4624 Figure 3, so that the later pull-off load is applied without bending. It is used by coatings labs and QC departments that bond test cylinders in batches and want every assembly aligned the same way. See our complete ISO 4624 guide for specimen preparation, procedure and calculations.
How the assemblies are held
The device consists of two aligned aluminum bars with matching bores. The bores are Ø 20 mm (0.79 in) and the height is 40 mm (1.57 in). The bores in the two bars line up with each other, so test cylinders placed in them are held on one axis with the specimen while the adhesive sets. Wing nuts clamp the bars by hand, with no tools, and keep everything in position for the full cure time. Because each bar carries a row of bores, several test assemblies can be prepared in one setup instead of one at a time.
Aluminum keeps the device light, so it is easy to load at the bench, move while the adhesive cures and store between batches.
Specifications and versions
Function: specimen preparation, coaxial bonding
Bore diameter: 20 mm
Height: 40 mm
Positions: multiple; number on request
Clamping: wing nuts
Material: aluminum
The temperature range is on request, so tell us if your adhesive is cured in an oven. Versions for another test cylinder diameter or a different number of positions are quoted on request. Drawings and 3D models of the device are also available on request.
Typical applications
Paints and varnishes
Protective coatings
Adhesive bonds
Thermal spray coatings
After bonding
The centering device is used on the bench and is not mounted in a testing machine. Once the adhesive has cured, the bonded assemblies are pulled in a tensile testing machine. We supply Galdabini universal testing machines and the couplings and adapters for the pull-off load train; the load range depends on your coating and cylinder size and is confirmed at quote. Related equipment for bonded joints is listed on our adhesives testing page.
Tell us your test cylinder diameter and the number of positions you need, and we'll quote the device. Request a quote or call 978-882-1480.
Adhesion Test Centering Device ISO 4624 Specifications
FUNCTION
Specimen preparation, coaxial bonding
BORE DIAMETER
20 mm
HEIGHT
40 mm
POSITIONS
Multiple; on request
CLAMPING
Wing nuts
MATERIAL
Aluminum
TEMPERATURE RANGE
On request
STANDARD
ISO 4624 (Figure 3)
PART REF.
UGC-ST-030
Models & Options
Standard centering device — Two aligned aluminum bars, bores Ø 20 mm, height 40 mm, wing-nut clamping (Specify at order)
Number of positions — Position count to suit your batch size (On request)
Other cylinder diameters — Bores made for a different test cylinder diameter (On request)
What's Included
Centering device with two aligned aluminum bars and matching bores
Wing nuts for clamping the bars
Test cylinders, adhesive and pull-off couplings are not listed on the data sheet; ask for them with your quote
Dimensional drawings or 3D models on request
Supported Test Standards
ISO 4624 — Paints and varnishes – pull-off test for adhesion
Compatible Grips & Fixtures
Universal Testing Machines — Galdabini frames for pulling the bonded assemblies after cure
Adapters — Couplings for the pull-off load train
Adhesives Testing — Grips and fixtures for bonded joints and coatings
Standard-Specific Test Fixtures — Other fixtures made for one named test
“Customer quote”
Related Equipment
UGC-ST-020 Adhesion and Shear Test Fixture OST
Nickel-coated steel fixtures for adhesion tests to OST 1-90016 and layer shear tests to OST 92-1472 Method B on heat-shi
UGC-ST-430 Aluminum Adhesive Bond Wedge Fixture
Machine-driven wedge fixture, rated to 30 kN, for adhesive bond durability wedge tests on aluminum joints such as ASTM D
UGC-ST-010 Metallic Coating Bend Fixture
Bench-mounted, hand-crank bend fixture for qualitative adhesion checks on metallic coatings, designed for bend tests suc
UGC-ST-660 Inverted Probe Tack Fixture
Probe tack fixture for pressure-sensitive adhesives using the inverted probe method of ASTM D2979, for a machine load ce
Adhesion Test Centering Device ISO 4624 FAQ
What does the UGC-ST-030 centering device do?
It holds pull-off test cylinders coaxially with the specimen while the adhesive cures. Good alignment at this stage means the later pull-off load is applied without bending.
Is it mounted in the testing machine?
No. It is a bench-top preparation device; the bonded assemblies are removed after curing and pulled in a tensile testing machine.
What size test cylinders does it take?
The bores are Ø 20 mm and the height is 40 mm. Bores for another cylinder diameter are available on request.
How many assemblies can be prepared at once?
Several. The device has multiple positions and the number is specified on request to suit your batch size.
How are the bars clamped?
With wing nuts, tightened by hand. No tools are needed.
Where can I find the test procedure?
See our complete ISO 4624 guide for specimen preparation, procedure and calculations. This page covers the hardware only.
Can it go into an oven for heat-cured adhesives?
The temperature range is on request. Tell us your cure temperature and we will confirm before you order.