Home › Products › Standard-Specific Test Fixtures › Inverted Probe Tack Fixture





Inverted Probe Tack Fixture – ASTM D2979
Probe tack fixture for pressure-sensitive adhesives using the inverted probe method of ASTM D2979, for a machine load cell or with a 20 N force gauge.
Brand: Universal Grip | Model: UGC-ST-660 | ● Configured to order
Designed for the inverted probe tack method of ASTM D2979
Stainless steel probe for a consistent contact surface
Anodized aluminum body; the load cell version weighs 0.86 kg (1.9 lb)
Version with integrated 20 N (4.5 lbf) force gauge available
Version without force gauge has an M6 internal-thread probe for your own load cell
Female clevis coupling Ø 15.9 mm (5/8 in) or Ø 20 mm; others via adapter
Temperature range 0 to +70 °C; others on request
Standards: ASTM D2979
Trusted by Global Companies


























Probe Tack Fixture for Pressure-Sensitive Adhesives
The UGC-ST-660 measures the pressure-sensitive tack of adhesives using the inverted probe method of ASTM D2979. A stainless steel probe contacts the adhesive under a defined load for a short dwell time and is then withdrawn; the force needed to separate the probe is recorded as tack. The fixture is made for label, tape and medical-patch producers and for adhesive formulators who need a quick, comparable tack value.
How it works
The fixture has an anodized aluminum body and a stainless steel probe. The stainless steel gives a consistent contact surface from test to test, which is what makes tack values comparable between batches. The body couples to the load train through a female clevis, Ø 15.9 mm (5/8 in) or Ø 20 mm, and other couplings are handled with adapters. Depending on the version, force is measured by the testing machine's load cell, by a force gauge supplied with the fixture, or by your own load cell threaded onto the probe.
Three versions
Load cell version: fixture with probe for use with the testing machine load cell. Weight 0.86 kg (1.9 lb).
With force gauge: fixture including a 20 N (4.5 lbf) force gauge. Weight 1.7 kg (3.7 lb).
Without force gauge: fixture with an M6 internal-thread probe and nut, for connecting your own load cell. Weight 0.9 kg (2.0 lb).
Maximum load is 20 N for the force gauge version; for the load cell version it is set by the load cell you use. The working temperature range is 0 to +70 °C (32 to 158 °F), with other ranges on request. The scope of supply is one fixture with probe. The body weighs under 1 kg in the load cell version, so it adds little to the load train of a small frame.
Typical applications
Pressure-sensitive adhesives
Labels and adhesive tapes
Medical adhesive patches
Adhesive formulation R&D
Machine fit
Tack forces are small, so the fixture belongs on a low-capacity frame with a sensitive load cell. It suits Mark-10 F-series motorized testers and Galdabini benchtop universal testing machines; coupling and load cell range are confirmed at quote. If you need a separate gauge or sensor, see our force gauges.
For a different tack method on the same materials, see the UGC-PL-190 loop tack test fixture, and for bond strength after application see our peel fixtures.
Tell us which version you need (load cell, with force gauge or without force gauge) and your machine coupling, and we'll configure the fixture. Request a quote or call 978-882-1480.
Product video
At a glance
Test type: Probe tack, pressure-sensitive adhesives
Max. load: 20 N (force gauge version); load cell version per load cell
Probe: Stainless steel
Body: Aluminum, anodized
Coupling: Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm; others via adapter
Temperature range: 0 to +70 °C; others on request
Inverted Probe Tack Fixture Specifications
TEST TYPE
Probe tack, pressure-sensitive adhesives
MAX. LOAD
20 N (force gauge version); load cell version per load cell
PROBE
Stainless steel
BODY
Aluminum, anodized
COUPLING
Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm; others via adapter
TEMPERATURE RANGE
0 to +70 °C; others on request
WEIGHT
0.86 kg (load cell version); 1.7 kg with force gauge; 0.9 kg without
SCOPE OF SUPPLY
1 fixture with probe
STANDARD
ASTM D2979
PART REF.
UGC-ST-660
Models & Options
Load cell version — Fixture with probe for use with the testing machine load cell; 0.86 kg (Specify at order)
With force gauge — Fixture including 20 N force gauge; 1.7 kg (Specify at order)
Without force gauge — Fixture with M6 internal-thread probe and nut, for your own load cell; 0.9 kg (Specify at order)
Coupling — Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm; other couplings via adapter (Specify at order)
Other temperature ranges — Versions for use outside 0 to +70 °C (On request)
What's Included
1 fixture with stainless steel probe, in the version ordered
With-force-gauge version: 20 N force gauge included
Without-force-gauge version: M6 internal-thread probe with 1 nut
Female clevis coupling Ø 15.9 mm (5/8 in) or Ø 20 mm
Testing machine and load cell are not part of the fixture
Supported Test Standards
ASTM D2979 — Pressure-sensitive tack of adhesives using an inverted probe machine
Compatible Grips & Fixtures
Mark-10 Motorized Tensile Testers — Low-capacity frames suited to small tack forces
Galdabini Benchtop Universal Testing Machines — Benchtop frames; load cell range confirmed at quote
UGC-PL-190 Loop Tack Test Fixture — Loop tack method for tapes and labels
Peel Fixtures — Peel adhesion tests on tapes, labels and laminates
Force Gauges — Gauges and sensors for low-force measurements
Adapters — Couplings other than Ø 15.9 mm or Ø 20 mm clevis
“Customer quote”
Related Equipment
UGC-ST-430 Aluminum Adhesive Bond Wedge Fixture
Machine-driven wedge fixture, rated to 30 kN, for adhesive bond durability wedge tests on aluminum joints such as ASTM D
UGC-ST-700 Metal-to-Metal Adhesive Cleavage Fixture
Carrier-and-insert fixture for cleavage strength tests on metal-to-metal adhesive bonds, rated 10 kN with a 35 kN versio
UGC-ST-030 Adhesion Test Centering Device ISO 4624
Multi-position aluminum centering device that holds pull-off test cylinders coaxial with the specimen while the adhesive
UGC-ST-750 Flatwise Tensile Adhesion Fixture
Carrier-and-insert tensile fixture, rated 20 kN, for tension perpendicular to the surface of sandwich cores, panels, ins
Inverted Probe Tack Fixture FAQ
What does the UGC-ST-660 measure?
The pressure-sensitive tack of adhesives using the inverted probe method of ASTM D2979. A stainless steel probe touches the adhesive under a defined load for a short dwell time, and the force to pull it away is recorded as tack.
Which versions are available?
Three: a load cell version for use with the testing machine load cell, a version including a 20 N force gauge, and a version without force gauge that has an M6 internal-thread probe and nut for your own load cell.
What is the maximum load?
20 N (4.5 lbf) for the force gauge version. For the load cell version the limit is set by the load cell used.
How does it connect to the testing machine?
Through a female clevis, Ø 15.9 mm (5/8 in) or Ø 20 mm. Other couplings are available via adapters.
What is the temperature range?
0 to +70 °C (32 to 158 °F). Other ranges are available on request.
Which testing machines suit a probe tack test?
Low-capacity frames with a sensitive load cell, such as Mark-10 F-series motorized testers or a Galdabini benchtop machine. Coupling and load cell range are confirmed at quote.
Do you also offer a loop tack fixture?
Yes, see the UGC-PL-190 loop tack test fixture.