top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Inverted Probe Tack Fixture

UGC-ST-660 inverted probe tack fixture with stainless steel probe and anodized aluminum body by Universal Grip
UGC-ST-660 inverted probe tack fixture with stainless steel probe and anodized aluminum body by Universal Grip
UGC-ST-660 Inverted Probe Tack Fixture by Universal Grip, view 2
UGC-ST-660 Inverted Probe Tack Fixture by Universal Grip, view 3
UGC-ST-660 Inverted Probe Tack Fixture by Universal Grip, view 4

Inverted Probe Tack Fixture – ASTM D2979

Probe tack fixture for pressure-sensitive adhesives using the inverted probe method of ASTM D2979, for a machine load cell or with a 20 N force gauge.

Brand: Universal Grip  |  Model: UGC-ST-660  |  ● Configured to order

  • Designed for the inverted probe tack method of ASTM D2979

  • Stainless steel probe for a consistent contact surface

  • Anodized aluminum body; the load cell version weighs 0.86 kg (1.9 lb)

  • Version with integrated 20 N (4.5 lbf) force gauge available

  • Version without force gauge has an M6 internal-thread probe for your own load cell

  • Female clevis coupling Ø 15.9 mm (5/8 in) or Ø 20 mm; others via adapter

  • Temperature range 0 to +70 °C; others on request

Standards: ASTM D2979

Trusted by Global Companies

Probe Tack Fixture for Pressure-Sensitive Adhesives

The UGC-ST-660 measures the pressure-sensitive tack of adhesives using the inverted probe method of ASTM D2979. A stainless steel probe contacts the adhesive under a defined load for a short dwell time and is then withdrawn; the force needed to separate the probe is recorded as tack. The fixture is made for label, tape and medical-patch producers and for adhesive formulators who need a quick, comparable tack value.

 

How it works

The fixture has an anodized aluminum body and a stainless steel probe. The stainless steel gives a consistent contact surface from test to test, which is what makes tack values comparable between batches. The body couples to the load train through a female clevis, Ø 15.9 mm (5/8 in) or Ø 20 mm, and other couplings are handled with adapters. Depending on the version, force is measured by the testing machine's load cell, by a force gauge supplied with the fixture, or by your own load cell threaded onto the probe.

 

Three versions

  • Load cell version: fixture with probe for use with the testing machine load cell. Weight 0.86 kg (1.9 lb).

  • With force gauge: fixture including a 20 N (4.5 lbf) force gauge. Weight 1.7 kg (3.7 lb).

  • Without force gauge: fixture with an M6 internal-thread probe and nut, for connecting your own load cell. Weight 0.9 kg (2.0 lb).

Maximum load is 20 N for the force gauge version; for the load cell version it is set by the load cell you use. The working temperature range is 0 to +70 °C (32 to 158 °F), with other ranges on request. The scope of supply is one fixture with probe. The body weighs under 1 kg in the load cell version, so it adds little to the load train of a small frame.

 

Typical applications

  • Pressure-sensitive adhesives

  • Labels and adhesive tapes

  • Medical adhesive patches

  • Adhesive formulation R&D

 

Machine fit

Tack forces are small, so the fixture belongs on a low-capacity frame with a sensitive load cell. It suits Mark-10 F-series motorized testers and Galdabini benchtop universal testing machines; coupling and load cell range are confirmed at quote. If you need a separate gauge or sensor, see our force gauges.

For a different tack method on the same materials, see the UGC-PL-190 loop tack test fixture, and for bond strength after application see our peel fixtures.

Tell us which version you need (load cell, with force gauge or without force gauge) and your machine coupling, and we'll configure the fixture. Request a quote or call 978-882-1480.

Product video

At a glance

  • Test type: Probe tack, pressure-sensitive adhesives

  • Max. load: 20 N (force gauge version); load cell version per load cell

  • Probe: Stainless steel

  • Body: Aluminum, anodized

  • Coupling: Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm; others via adapter

  • Temperature range: 0 to +70 °C; others on request

Inverted Probe Tack Fixture Specifications

TEST TYPE

Probe tack, pressure-sensitive adhesives

 

MAX. LOAD

20 N (force gauge version); load cell version per load cell

 

PROBE

Stainless steel

 

BODY

Aluminum, anodized

 

COUPLING

Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm; others via adapter

 

TEMPERATURE RANGE

0 to +70 °C; others on request

 

WEIGHT

0.86 kg (load cell version); 1.7 kg with force gauge; 0.9 kg without

 

SCOPE OF SUPPLY

1 fixture with probe

 

STANDARD

ASTM D2979

 

PART REF.

UGC-ST-660

 

Models & Options

  • Load cell version — Fixture with probe for use with the testing machine load cell; 0.86 kg (Specify at order)

  • With force gauge — Fixture including 20 N force gauge; 1.7 kg (Specify at order)

  • Without force gauge — Fixture with M6 internal-thread probe and nut, for your own load cell; 0.9 kg (Specify at order)

  • Coupling — Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm; other couplings via adapter (Specify at order)

  • Other temperature ranges — Versions for use outside 0 to +70 °C (On request)

What's Included

  • 1 fixture with stainless steel probe, in the version ordered

  • With-force-gauge version: 20 N force gauge included

  • Without-force-gauge version: M6 internal-thread probe with 1 nut

  • Female clevis coupling Ø 15.9 mm (5/8 in) or Ø 20 mm

  • Testing machine and load cell are not part of the fixture

Supported Test Standards

  • ASTM D2979 — Pressure-sensitive tack of adhesives using an inverted probe machine

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-430 Aluminum Adhesive Bond Wedge Fixture

UGC-ST-430 Aluminum Adhesive Bond Wedge Fixture

Machine-driven wedge fixture, rated to 30 kN, for adhesive bond durability wedge tests on aluminum joints such as ASTM D

UGC-ST-700 Metal-to-Metal Adhesive Cleavage Fixture

UGC-ST-700 Metal-to-Metal Adhesive Cleavage Fixture

Carrier-and-insert fixture for cleavage strength tests on metal-to-metal adhesive bonds, rated 10 kN with a 35 kN versio

UGC-ST-030 Adhesion Test Centering Device ISO 4624

UGC-ST-030 Adhesion Test Centering Device ISO 4624

Multi-position aluminum centering device that holds pull-off test cylinders coaxial with the specimen while the adhesive

UGC-ST-750 Flatwise Tensile Adhesion Fixture

UGC-ST-750 Flatwise Tensile Adhesion Fixture

Carrier-and-insert tensile fixture, rated 20 kN, for tension perpendicular to the surface of sandwich cores, panels, ins

Inverted Probe Tack Fixture FAQ

What does the UGC-ST-660 measure?

The pressure-sensitive tack of adhesives using the inverted probe method of ASTM D2979. A stainless steel probe touches the adhesive under a defined load for a short dwell time, and the force to pull it away is recorded as tack.

 

Which versions are available?

Three: a load cell version for use with the testing machine load cell, a version including a 20 N force gauge, and a version without force gauge that has an M6 internal-thread probe and nut for your own load cell.

 

What is the maximum load?

20 N (4.5 lbf) for the force gauge version. For the load cell version the limit is set by the load cell used.

 

How does it connect to the testing machine?

Through a female clevis, Ø 15.9 mm (5/8 in) or Ø 20 mm. Other couplings are available via adapters.

 

What is the temperature range?

0 to +70 °C (32 to 158 °F). Other ranges are available on request.

 

Which testing machines suit a probe tack test?

Low-capacity frames with a sensitive load cell, such as Mark-10 F-series motorized testers or a Galdabini benchtop machine. Coupling and load cell range are confirmed at quote.

 

Do you also offer a loop tack fixture?

Yes, see the UGC-PL-190 loop tack test fixture.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page