Battery Handle Strength Fixture EN 50342-5 – 5 kN

Pull test fixture for the carrying handles of lead-acid starter batteries, designed for EN 50342-5 clause 4.4.4 tests and rated for 5 kN.

Brand: Universal Grip  |  Model: UGC-ST-090  |  ● Configured to order

  • Designed for handle strength tests such as EN 50342-5, clause 4.4.4

  • Upper hook-type pulling device engages the battery handle

  • Lower T-slot holding plate with adjustable clamping bars secures the battery

  • Handles batteries of different case sizes on one base

  • Nickel-plated steel construction for durability and corrosion resistance

  • Rated for loads up to 5 kN (1,124 lbf)

Standards: EN 50342-5

Trusted by Global Companies

Handle pull fixture for lead-acid starter batteries

The UGC-ST-090 checks the strength of the carrying handles on lead-acid starter batteries. It is designed for tests such as EN 50342-5, clause 4.4.4, and is used by battery manufacturers, housing developers and production QC laboratories that need to load the handle of a complete battery in a testing machine.

 

How it works

The fixture comes in two parts. The lower part is a holding plate with T-slots and clamping bars: the battery stands on the plate and the bars secure it. The upper part is a hook-type pulling device that engages the handle. With the battery held down and the hook under the handle, the testing machine applies the specified tensile load. The complete battery is tested as it is, so the result reflects the handle and its attachment to the case together.

 

One base for different battery sizes

Starter batteries come in many case sizes. Because the clamping bars are adjustable on the T-slot plate, one base handles batteries of different case sizes, so a lab does not need a separate nest for every battery type. Give us your battery case dimensions when you order so we can confirm the plate and bars cover your range.

 

Construction and ratings

  • Max. load: 5 kN (1,124 lbf)

  • Scope of supply: upper pulling device and lower holding plate

  • Material: nickel-plated steel for durability and corrosion resistance

  • Coupling: on request, made to suit your machine

  • Temperature range: on request

 

Typical applications

  • Automotive starter batteries

  • Battery handle qualification

  • Battery production quality control

  • Battery housing development

 

Machine fit

A 5 kN rating puts this fixture on a benchtop universal testing machine, such as our Galdabini 5 kN or 10 kN frames. Two things need checking before you order. The holding plate has to mount on the machine base, and the battery, handle and hook all have to fit in the test space. Send us your machine model along with the battery dimensions and we will confirm both. The coupling is specified at order, and adapters are available. If your procedure calls for a different load capacity, say so and we will quote for it.

Dimensional drawings and 3D models are available on request, which helps when checking the holding plate against your machine base.

Looking for other product-specific tests? Browse our standard-specific test fixtures.

Tell us your battery case dimensions, machine coupling and required load capacity and we'll configure the fixture — request a quote.

Product video

At a glance

  • Max. load: 5 kN (1,124 lbf)

  • Test type: Tensile, battery handle strength

  • Standard: EN 50342-5 (4.4.4)

  • Specimen: Lead-acid starter batteries

  • Scope of supply: Upper pulling device and lower holding plate

  • Material: Steel, nickel-plated

Battery Handle Strength Fixture EN 50342-5 Specifications

MAX. LOAD

5 kN (1,124 lbf)

 

TEST TYPE

Tensile, battery handle strength

 

STANDARD

EN 50342-5 (4.4.4)

 

SPECIMEN

Lead-acid starter batteries

 

SCOPE OF SUPPLY

Upper pulling device and lower holding plate

 

MATERIAL

Steel, nickel-plated

 

COUPLING

On request

 

TEMPERATURE RANGE

On request

 

PART REF.

UGC-ST-090

 

Models & Options

  • Standard fixture — Upper hook-type pulling device and lower T-slot holding plate with clamping bars, 5 kN (Specify at order)

  • Battery case size — Holding plate and clamping bars confirmed for your battery case dimensions (Specify at order)

  • Machine coupling — Coupling made to suit your testing machine (On request)

  • Other load capacity — Versions for a different required load capacity (On request)

What's Included

  • Upper hook-type pulling device

  • Lower T-slot holding plate

  • Adjustable clamping bars for securing the battery

  • Machine coupling as specified at order

Supported Test Standards

  • EN 50342-5 — Lead-acid starter batteries – properties of battery housings and handles

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-060 Automotive Cable Flexibility Fixture ISO 19642-2

UGC-ST-060 Automotive Cable Flexibility Fixture ISO 19642-2

Three-pulley bending fixture for measuring the flexibility of automotive cables, designed for ISO 19642-2 tests, with pu

UGC-ST-590 Electrical Varnish Helical Coil Bond Fixture

UGC-ST-590 Electrical Varnish Helical Coil Bond Fixture

Helical coil bond strength fixture for electrical insulating varnishes, designed for ASTM D2519 tests, with roller suppo

UGC-ST-640 Mattress Firmness Ram Head

UGC-ST-640 Mattress Firmness Ram Head

Twin hemispherical ram head in anodized aluminum for mattress firmness retention and surface deformation tests, with the

UGC-ST-610 Wire Insulation Notch Resistance Fixture

UGC-ST-610 Wire Insulation Notch Resistance Fixture

Cut-through fixture for notch resistance testing of wire and cable insulation, designed for LV 112 and ASTM D3032 tests;

Battery Handle Strength Fixture EN 50342-5 FAQ

What does the battery handle strength fixture test?

It checks the strength of the carrying handles on lead-acid starter batteries. It is designed for tests such as EN 50342-5, clause 4.4.4.

 

How is the battery held?

The battery stands on a lower holding plate with T-slots and is secured with adjustable clamping bars. An upper hook-type pulling device engages the handle.

 

Can one fixture handle different battery sizes?

Yes. The adjustable clamping bars let one base take batteries of different case sizes. Send your case dimensions so we can confirm the range.

 

What is the maximum load?

The fixture is rated for 5 kN (1,124 lbf). Tell us if your procedure needs a different load capacity.

 

Which coupling does it have?

The coupling is on request and is made to suit your testing machine. Adapters are also available.

 

Which testing machine do I need?

A benchtop universal testing machine of 5 kN or more, such as our Galdabini 5 kN frame. We check that the holding plate and the battery fit your machine before you order.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.