Home › Products › Standard-Specific Test Fixtures › Needle Tubing Bend Fixture





Needle Tubing Bend Fixture – ISO 9626 Annex C
Bend test fixture for stiffness tests on stainless steel needle tubing, capillary tubes and cannulas, rated to 1 kN.
Brand: Universal Grip | Model: UGC-ST-130 | ● Configured to order
Designed for needle tubing bend tests such as ISO 9626 Annex C
Suitable for injection tubes, capillary tubes and cannulas
Rated for loads up to 1 kN (about 225 lbf)
Aluminum, steel and plastic construction keeps the fixture light
Female clevis coupling for a Ø 15.9 mm (5/8 in) or Ø 20 mm pin; others via adapter
Available as a complete fixture or without the lower bar
Temperature range 0 to +70 °C (32 to 158 °F); other ranges on request
Standards: ISO 9626
Trusted by Global Companies


























Bend fixture for stiffness tests on stainless steel needle tubing
The UGC-ST-130 is a bend test fixture for stainless steel needle tubing, designed for the stiffness test in ISO 9626 Annex C. Tubing producers, needle manufacturers and medical device QC labs use it to check injection needles, capillary tubes and cannulas. It is a light fixture in aluminum, steel and plastic, rated for loads up to 1 kN (about 225 lbf).
How it works
The tube rests on the lower supports. An upper loading element, moved by the crosshead, comes down on the tube and deflects it. The testing machine records force against deflection, and the stiffness of the tube is taken from that relationship.
Needle tubing is small and bends under very little force, so the low weight of the fixture and a low-capacity load cell both help the measurement.
Available versions
Standard version: the complete bend fixture, including the lower bar.
Without lower bar: the same fixture, supplied without the lower bar.
The scope of supply is one fixture in the version ordered. Both versions share the same load rating, materials and coupling choices. Let us know whether the lower bar is required when you ask for a quote.
Coupling, temperature and machine fit
The fixture is available with a female clevis for a Ø 15.9 mm (5/8 in) pin or a Ø 20 mm (0.79 in) pin; other machine connections are made with an adapter. The working temperature range is 0 to +70 °C (32 to 158 °F), with other ranges on request.
At 1 kN the fixture fits low-force frames such as a Mark-10 F-series motorized 300 lb tester or a Galdabini 2.5 kN benchtop universal testing machine. A dimensional drawing is part of the data sheet, and further drawings and 3D models are available on request.
Typical applications
Hypodermic needle tubing
Capillary and cannula tubes
Tube stiffness testing
Medical device QC
Related fixtures
For bend tests on larger specimens see our general bend testing fixtures. For a 90° bend test on finished needles with a hub, see the UGC-ST-150 syringe needle test fixture, and for the bond between needle tube and hub see the UGC-ST-110 hypodermic needle tensile fixture.
Send us the tube outer diameters, your machine coupling and whether you need the lower bar, and we will configure the fixture. Request a quote.
Needle Tubing Bend Fixture Specifications
MAX. LOAD
1 kN (approx. 225 lbf)
TEST TYPE
Bend (stiffness)
STANDARD
ISO 9626 Annex C
SPECIMEN
Stainless steel needle tubing
COUPLING
Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm pin; others via adapter
MATERIAL
Aluminum, steel, plastic
TEMPERATURE RANGE
0 … +70 °C (32 … 158 °F); other ranges on request
SCOPE OF SUPPLY
1 fixture
DRAWINGS
Dimensional drawing on the data sheet; 3D models on request
PART REF.
UGC-ST-130
Models & Options
Standard version — Complete bend fixture with lower bar (Specify at order)
Without lower bar — Same fixture, supplied without the lower bar (Specify at order)
Coupling Ø 15.9 mm or Ø 20 mm — Female clevis for either pin size (Specify at order)
Other couplings — Other machine connections via adapter (On request)
Other temperature ranges — Versions for use outside 0 to +70 °C (On request)
What's Included
1 bend fixture in the version ordered (with or without the lower bar)
Female clevis coupling for a Ø 15.9 mm (5/8 in) or Ø 20 mm pin, as specified
Dimensional drawings and 3D models available on request
Supported Test Standards
ISO 9626 — Stainless steel needle tubing for the manufacture of medical devices
Compatible Grips & Fixtures
300 lb Tensile Tester — Mark-10 F-series motorized frame for low-force bend tests
2.5 kN Benchtop Universal Testing Machine — Galdabini benchtop frame; use with a small load cell
UGC-ST-150 Syringe Needle Test Fixture — 90° bend tests on finished needles with hub
Bend Testing Fixtures — General three- and four-point bend fixtures
Adapters — Couplings for other machine connections
Bend Testing — Overview of bend test methods and equipment
“Customer quote”
Related Equipment
UGC-ST-110 Hypodermic Needle Tensile Fixture ISO 7864
Drill-chuck tensile fixture on a cardan joint for needle tube-to-hub bond tests on single-use hypodermic needles, rated
UGC-ST-150 Syringe Needle Test Fixture
Stainless steel fixture with spring-loaded hub holder and fork-shaped loading member for 90° bend tests on syringe needl
UGC-ST-120 Syringe Cartridge Test Fixture ISO 11608-3
Upper plunger rod and lower cartridge holder for stopper force tests on pen-injector cartridges, rated to 100 N.
UGC-ST-140 Luer Cone Breakage Fixture ISO 11040-4
Fixture with PTFE syringe inserts, guided loading column and polycarbonate safety box for luer cone breakage tests on pr
Needle Tubing Bend Fixture FAQ
What is the UGC-ST-130 used for?
Bend (stiffness) tests on stainless steel needle tubing, including injection needles, capillary tubes and cannulas.
Which standard is it designed for?
Needle tubing bend tests such as ISO 9626 Annex C, the stiffness test for stainless steel needle tubing.
What is the difference between the two versions?
The standard version is the complete fixture with the lower bar. The second version is the same fixture supplied without the lower bar.
What is the maximum load?
1 kN (about 225 lbf). Needle tubing bends at low force, so pair the fixture with a low-capacity load cell.
Which couplings are available?
A female clevis for a Ø 15.9 mm (5/8 in) pin or a Ø 20 mm pin. Other machine connections are made with an adapter.
What temperature range can it be used in?
0 to +70 °C (32 to 158 °F) as standard. Other ranges are on request; contact us with your test conditions.