Home › Products › Standard-Specific Test Fixtures › Syringe Holder with Interchangeable Inserts





Syringe Holder with Interchangeable Inserts
Nickel-plated steel syringe holder with interchangeable inserts for tension and compression tests on single-use syringes from 1.25 to 10 ml.
Brand: Universal Grip | Model: UGC-ST-160 | ● Configured to order
Interchangeable inserts accept syringes of different sizes, from 1.25 to 10 ml
Supports tension and compression tests in one holder
Measures the operating force needed to push fluid through the needle
Nickel-plated steel construction for durability and corrosion resistance
Optional height-adjustable cup table and additional container holder
Female clevis coupling for a Ø 15.9 mm (5/8 in) pin; other couplings via adapters
Temperature range 0 to +70 °C (32 to 158 °F)
Standards: ISO 7886-1 · ISO 11040-4
Trusted by Global Companies


























Syringe holder with interchangeable inserts for tension and compression tests
The UGC-ST-160 is a holder for tension and compression tests on sterile single-use hypodermic syringes, designed around the test arrangement shown in ISO 7886-1, Fig. E.1. Interchangeable inserts accept syringes of different sizes, so one holder serves a whole range of syringe volumes in disposable syringe QC, medical device development and prefillable syringe testing.
How the syringe is held and loaded
The syringe is placed in an insert that matches its size, and the insert sits in the holder. In compression, the testing machine presses on the plunger and records the operating force needed to push fluid through the needle. In tension, the tensile version holds the syringe while the plunger is pulled, which gives plunger pull-out forces. Moving to another syringe size means changing the insert, not the fixture.
Versions and inserts
Inserts 3 / 5 / 10 ml: insert set for standard syringe sizes.
Inserts 1.25 / 2.25 / 3 ml: insert set for small syringes.
Holder with 3 ml insert and holder with 10 ml insert: single-size holders.
Tensile version, 3 and 5 ml: holder with inserts for tensile tests.
With cup table: height-adjustable cup table for fluid collection.
An additional container holder is available as an option. Dimensional drawings and 3D models are available on request.
Construction and machine fit
The holder is nickel-plated steel for durability and corrosion resistance and is used from 0 to +70 °C (32 to 158 °F). It mounts through a female clevis with a Ø 15.9 mm (5/8 in) pin; other machine connections are made with adapters. The maximum load is on request, and we confirm the fit to your testing machine and load cell at quote.
Related standards and fixtures
The holder is also suitable for tests related to ISO 11040-4. See our complete ISO 11040-4 guide for specimen preparation, procedure and calculations. For the luer cone breakage test see the UGC-ST-140 luer cone breakage fixture, for pen-injector cartridges see the UGC-ST-120 syringe cartridge test fixture, and for a simple flange-supported pull test see the UGC-ST-100 syringe tensile holder.
Tell us the syringe volumes and types you test, the test direction (tension, compression or both) and your machine coupling, and we will put together the holder and inserts. Request a quote.
See our complete ISO 7886-1 guide for the piston operating force test, limits and procedure.
Syringe Holder with Interchangeable Inserts Specifications
TEST TYPE
Tension and compression
STANDARD
ISO 7886-1 (Fig. E.1)
SPECIMEN
Single-use hypodermic syringes
INSERTS
For 1.25, 2.25, 3, 5 and 10 ml syringes
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
0 … +70 °C (32 … 158 °F)
MAX. LOAD
On request
OPTIONS
Height-adjustable cup table; additional container holder
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-160
Models & Options
Inserts 3 / 5 / 10 ml — Insert set for standard syringe sizes (Specify at order)
Inserts 1.25 / 2.25 / 3 ml — Insert set for small syringes (Specify at order)
Holder with 3 ml insert — Single-size holder (Specify at order)
Holder with 10 ml insert — Single-size holder (Specify at order)
Tensile version 3 and 5 ml — Holder with inserts for tensile tests (Specify at order)
With cup table — Height-adjustable cup table for fluid collection (Specify at order)
Additional container holder — Extra holder for a container (On request)
What's Included
Syringe holder in the version ordered
Interchangeable inserts for the syringe sizes ordered
Female clevis coupling for a Ø 15.9 mm (5/8 in) pin
Cup table and additional container holder only when ordered as options
Dimensional drawings or 3D models available on request
Supported Test Standards
ISO 7886-1 — Sterile hypodermic syringes for single use – syringes for manual use
ISO 11040-4 — Prefilled syringes – glass barrels for injectables and ready-to-fill syringes
Compatible Grips & Fixtures
UGC-ST-140 Luer Cone Breakage Fixture — Breakage resistance of the luer cone on prefillable syringes
UGC-ST-100 Syringe Tensile Holder — Flange-supported holder for plunger pull-out tests
UGC-ST-120 Syringe Cartridge Test Fixture — Stopper force tests on pen-injector cartridges
Benchtop Universal Testing Machines — Galdabini benchtop frames; fit confirmed at quote
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-ST-100 Syringe Tensile Holder
Anodized aluminum upper holder that supports a syringe by its finger flange for plunger pull-out and flange strength tes
UGC-ST-120 Syringe Cartridge Test Fixture ISO 11608-3
Upper plunger rod and lower cartridge holder for stopper force tests on pen-injector cartridges, rated to 100 N.
UGC-ST-140 Luer Cone Breakage Fixture ISO 11040-4
Fixture with PTFE syringe inserts, guided loading column and polycarbonate safety box for luer cone breakage tests on pr
UGC-ST-150 Syringe Needle Test Fixture
Stainless steel fixture with spring-loaded hub holder and fork-shaped loading member for 90° bend tests on syringe needl
Syringe Holder with Interchangeable Inserts FAQ
What is the UGC-ST-160 used for?
Tension and compression tests on sterile single-use hypodermic syringes, such as the force needed to push fluid through the needle and plunger pull-out forces.
Which syringe sizes does it take?
Inserts are available for 1.25, 2.25, 3, 5 and 10 ml syringes, supplied as sets or as single-size holders for 3 ml or 10 ml.
Can one holder do both tension and compression?
Yes, the holder supports both directions. For pull tests, order the tensile version with inserts for 3 and 5 ml syringes.
Which standards is it used with?
It is designed around ISO 7886-1, Fig. E.1 and is also suitable for tests related to ISO 11040-4. Our ISO 11040-4 guide covers specimen preparation, procedure and calculations.
What is the cup table for?
It is an optional, height-adjustable table that holds a cup under the syringe to collect the fluid expelled during the test.
What is the maximum load and temperature range?
The temperature range is 0 to +70 °C (32 to 158 °F). The maximum load is on request and is confirmed at quote.
How does it mount on my testing machine?
With a female clevis for a Ø 15.9 mm (5/8 in) pin. Other machine connections are available through adapters.