Dental Implant Dynamic Loading Fixture ISO 14801

Inclined clamping fixture for dynamic loading tests on endosseous dental implants, with a screw vise, serrated jaws and a separate loading member.

Brand: Universal Grip  |  Model: UGC-ST-210  |  ● Configured to order

  • Designed for dynamic loading (fatigue) tests on endosseous dental implants such as ISO 14801

  • Inclined block sets the implant at the required loading angle

  • Screw-driven vise with serrated jaws clamps the implant holder

  • Separate loading member transmits the force to the abutment

  • Suitable for servo-hydraulic and electrodynamic test machines

  • Male clevis or M20 x 1.5 male thread connection; others via adapter

Standards: ISO 14801

Trusted by Global Companies

Inclined clamping fixture for dental implant dynamic loading tests

The UGC-ST-210 is a fixture for dynamic loading tests on endosseous dental implants, designed for tests such as ISO 14801. It is intended for dental implant developers, laboratories that produce fatigue data for regulatory submissions, and manufacturers who check abutment systems as part of QC. The fixture holds the implant at an angle to the load axis and provides the loading member that bears on the abutment.

 

How it works

The implant, in its holder, is clamped in a screw-driven vise with serrated jaws. The vise is mounted on an inclined block. The testing machine still pushes along its own axis, but because the vise sits on the incline, the load acts on the implant at the angle required by the standard. A separate loading member, connected to the machine, transmits the force to the implant abutment. The vise is tightened by its screw, so implant holders can be exchanged between tests without disturbing the incline.

 

Main features

  • Inclined block: sets the implant at the required loading angle.

  • Screw-driven vise: serrated jaws clamp the implant holder.

  • Separate loading member: carries the machine force to the abutment.

  • Steel construction.

 

Connections and machine fit

Two machine connections are offered: a male clevis or an M20 x 1.5 male thread. The clevis pin size is confirmed at quote, and other connections are made with an adapter. The fixture is suitable for servo-hydraulic and electrodynamic test machines and is supplied for your own dynamic or static machine; we confirm the fit when we quote. The maximum load is on request, so tell us the dynamic load range of your test program. For holding other specimens under cyclic load, see our fatigue grips.

 

Testing in a liquid bath

The UGC-ST-210 does not include a liquid bath. If your protocol calls for the implant to be loaded while immersed, look at the UGC-LB-010 dental implant fluid bath loading fixture instead.

 

Typical applications

  • Dental implant development, comparing implant bodies, connections and abutments

  • Implant fatigue testing

  • Regulatory submission testing

  • Abutment system QC

 

Ordering

Implant systems vary widely, so this fixture is configured to the parts you test. Send us the implant diameter and length, the loading angle, your machine connection and the dynamic load range. Dimensional drawings and 3D models are available on request. Related dental fixtures include the UGC-ST-190 dental restorative bond shear fixture. Request a quote with your implant details and we will confirm the configuration.

See our complete ISO 14801 guide for the test geometry, loading, run-out cycles and reporting.

Product video

At a glance

  • Test type: Dynamic loading (fatigue)

  • Standard: ISO 14801

  • Specimen: Endosseous dental implants

  • Specimen holding: Screw vise on inclined block

  • Loading: Separate loading member acting on the abutment

  • Coupling: Male clevis or M20 x 1.5 male thread; others via adapter

Dental Implant Dynamic Loading Fixture ISO 14801 Specifications

TEST TYPE

Dynamic loading (fatigue)

 

STANDARD

ISO 14801

 

SPECIMEN

Endosseous dental implants

 

SPECIMEN HOLDING

Screw vise on inclined block

 

LOADING

Separate loading member acting on the abutment

 

COUPLING

Male clevis or M20 x 1.5 male thread; others via adapter

 

MAX. LOAD

On request

 

MATERIAL

Steel

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-ST-210

 

Models & Options

  • Male clevis connection — Male clevis coupling; pin size confirmed at quote (Specify at order)

  • M20 x 1.5 thread connection — M20 x 1.5 male thread coupling (Specify at order)

  • Loading angle — Inclined block for the loading angle you specify (Specify at order)

  • Other couplings — Adapters for other machine connections (On request)

What's Included

  • Inclined block with screw-driven vise and serrated jaws

  • Separate loading member for the implant abutment

  • Machine connection as ordered: male clevis or M20 x 1.5 male thread

  • Testing machine and implant holders are not included unless agreed at quote

Supported Test Standards

  • ISO 14801 — Dynamic loading test for endosseous dental implants

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-190 Dental Restorative Bond Shear Fixture

UGC-ST-190 Dental Restorative Bond Shear Fixture

Stainless steel shear fixture, rated to 5 kN, for bond strength between dental restorative materials and tooth structure

UGC-ST-200 Hip Prosthesis Endurance Fixture ISO 7206-4

UGC-ST-200 Hip Prosthesis Endurance Fixture ISO 7206-4

Endurance test fixture, rated to 30 kN, for stemmed femoral components of hip prostheses, with pot holder, angle-adjusta

UGC-ST-570 Motorized O-Ring Tensile Tester ISO 4074

UGC-ST-570 Motorized O-Ring Tensile Tester ISO 4074

Motorized roller fixture, rated to 10 kN, that rotates rubber ring specimens at 1–25 r/min during the tensile test for e

UGC-ST-820 Spectacle Lens Test Fixture ISO 14889

UGC-ST-820 Spectacle Lens Test Fixture ISO 14889

Static load fixture for uncut finished spectacle lenses: lens support, guided central ram and transparent safety shield,

Dental Implant Dynamic Loading Fixture ISO 14801 FAQ

What is the UGC-ST-210 used for?

Dynamic loading (fatigue) tests on endosseous dental implants, such as ISO 14801. It clamps the implant on an inclined block and provides a separate loading member for the abutment.

 

How is the loading angle set?

By the inclined block under the vise. Specify the loading angle when you order and the fixture is configured for it.

 

How is the implant clamped?

The implant holder is clamped in a screw-driven vise with serrated jaws, mounted on the inclined block.

 

What is the maximum load?

The maximum load is on request. Tell us the dynamic load range of your test program and we will confirm it at quote.

 

Which machine connections are available?

A male clevis or an M20 x 1.5 male thread, with other connections through adapters. The fixture is suitable for servo-hydraulic and electrodynamic test machines, and fit is confirmed at quote.

 

Can the implant be tested in liquid?

This fixture does not include a liquid bath. For loading in a bath, see the UGC-LB-010 dental implant fluid bath loading fixture.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.