Home › Products › Standard-Specific Test Fixtures › Dental Implant Dynamic Loading Fixture ISO 14801





Dental Implant Dynamic Loading Fixture ISO 14801
Inclined clamping fixture for dynamic loading tests on endosseous dental implants, with a screw vise, serrated jaws and a separate loading member.
Brand: Universal Grip | Model: UGC-ST-210 | ● Configured to order
Designed for dynamic loading (fatigue) tests on endosseous dental implants such as ISO 14801
Inclined block sets the implant at the required loading angle
Screw-driven vise with serrated jaws clamps the implant holder
Separate loading member transmits the force to the abutment
Suitable for servo-hydraulic and electrodynamic test machines
Male clevis or M20 x 1.5 male thread connection; others via adapter
Standards: ISO 14801
Trusted by Global Companies


























Inclined clamping fixture for dental implant dynamic loading tests
The UGC-ST-210 is a fixture for dynamic loading tests on endosseous dental implants, designed for tests such as ISO 14801. It is intended for dental implant developers, laboratories that produce fatigue data for regulatory submissions, and manufacturers who check abutment systems as part of QC. The fixture holds the implant at an angle to the load axis and provides the loading member that bears on the abutment.
How it works
The implant, in its holder, is clamped in a screw-driven vise with serrated jaws. The vise is mounted on an inclined block. The testing machine still pushes along its own axis, but because the vise sits on the incline, the load acts on the implant at the angle required by the standard. A separate loading member, connected to the machine, transmits the force to the implant abutment. The vise is tightened by its screw, so implant holders can be exchanged between tests without disturbing the incline.
Main features
Inclined block: sets the implant at the required loading angle.
Screw-driven vise: serrated jaws clamp the implant holder.
Separate loading member: carries the machine force to the abutment.
Steel construction.
Connections and machine fit
Two machine connections are offered: a male clevis or an M20 x 1.5 male thread. The clevis pin size is confirmed at quote, and other connections are made with an adapter. The fixture is suitable for servo-hydraulic and electrodynamic test machines and is supplied for your own dynamic or static machine; we confirm the fit when we quote. The maximum load is on request, so tell us the dynamic load range of your test program. For holding other specimens under cyclic load, see our fatigue grips.
Testing in a liquid bath
The UGC-ST-210 does not include a liquid bath. If your protocol calls for the implant to be loaded while immersed, look at the UGC-LB-010 dental implant fluid bath loading fixture instead.
Typical applications
Dental implant development, comparing implant bodies, connections and abutments
Implant fatigue testing
Regulatory submission testing
Abutment system QC
Ordering
Implant systems vary widely, so this fixture is configured to the parts you test. Send us the implant diameter and length, the loading angle, your machine connection and the dynamic load range. Dimensional drawings and 3D models are available on request. Related dental fixtures include the UGC-ST-190 dental restorative bond shear fixture. Request a quote with your implant details and we will confirm the configuration.
See our complete ISO 14801 guide for the test geometry, loading, run-out cycles and reporting.
Dental Implant Dynamic Loading Fixture ISO 14801 Specifications
TEST TYPE
Dynamic loading (fatigue)
STANDARD
ISO 14801
SPECIMEN
Endosseous dental implants
SPECIMEN HOLDING
Screw vise on inclined block
LOADING
Separate loading member acting on the abutment
COUPLING
Male clevis or M20 x 1.5 male thread; others via adapter
MAX. LOAD
On request
MATERIAL
Steel
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-210
Models & Options
Male clevis connection — Male clevis coupling; pin size confirmed at quote (Specify at order)
M20 x 1.5 thread connection — M20 x 1.5 male thread coupling (Specify at order)
Loading angle — Inclined block for the loading angle you specify (Specify at order)
Other couplings — Adapters for other machine connections (On request)
What's Included
Inclined block with screw-driven vise and serrated jaws
Separate loading member for the implant abutment
Machine connection as ordered: male clevis or M20 x 1.5 male thread
Testing machine and implant holders are not included unless agreed at quote
Supported Test Standards
ISO 14801 — Dynamic loading test for endosseous dental implants
Compatible Grips & Fixtures
UGC-LB-010 Dental Implant Fluid Bath Loading Fixture — Dental implant loading fixture with liquid bath
Fatigue Grips — Grips for other specimens under cyclic load
Adapters — Couplings for other machine connections
UGC-ST-190 Dental Restorative Bond Shear Fixture — Shear bond tests on dental restoratives
UGC-ST-200 Hip Prosthesis Endurance Fixture — Endurance fixture for hip stems
“Customer quote”
Related Equipment
UGC-ST-190 Dental Restorative Bond Shear Fixture
Stainless steel shear fixture, rated to 5 kN, for bond strength between dental restorative materials and tooth structure
UGC-ST-200 Hip Prosthesis Endurance Fixture ISO 7206-4
Endurance test fixture, rated to 30 kN, for stemmed femoral components of hip prostheses, with pot holder, angle-adjusta
UGC-ST-570 Motorized O-Ring Tensile Tester ISO 4074
Motorized roller fixture, rated to 10 kN, that rotates rubber ring specimens at 1–25 r/min during the tensile test for e
UGC-ST-820 Spectacle Lens Test Fixture ISO 14889
Static load fixture for uncut finished spectacle lenses: lens support, guided central ram and transparent safety shield,
Dental Implant Dynamic Loading Fixture ISO 14801 FAQ
What is the UGC-ST-210 used for?
Dynamic loading (fatigue) tests on endosseous dental implants, such as ISO 14801. It clamps the implant on an inclined block and provides a separate loading member for the abutment.
How is the loading angle set?
By the inclined block under the vise. Specify the loading angle when you order and the fixture is configured for it.
How is the implant clamped?
The implant holder is clamped in a screw-driven vise with serrated jaws, mounted on the inclined block.
What is the maximum load?
The maximum load is on request. Tell us the dynamic load range of your test program and we will confirm it at quote.
Which machine connections are available?
A male clevis or an M20 x 1.5 male thread, with other connections through adapters. The fixture is suitable for servo-hydraulic and electrodynamic test machines, and fit is confirmed at quote.
Can the implant be tested in liquid?
This fixture does not include a liquid bath. For loading in a bath, see the UGC-LB-010 dental implant fluid bath loading fixture.