top of page

Home  ›  Products  ›  Standard-Specific Test Fixtures  ›  Shoe Sole Tip Bond Fixture DIN 4843

UGC-ST-350 shoe sole tip bond fixture with wave jaws for DIN 4843 peel tests by Universal Grip
UGC-ST-350 shoe sole tip bond fixture with wave jaws for DIN 4843 peel tests by Universal Grip
UGC-ST-350 Shoe Sole Tip Bond Fixture DIN 4843 by Universal Grip, view 2
UGC-ST-350 Shoe Sole Tip Bond Fixture DIN 4843 by Universal Grip, view 3
UGC-ST-350 Shoe Sole Tip Bond Fixture DIN 4843 by Universal Grip, view 4

Shoe Sole Tip Bond Fixture DIN 4843

Wave-jaw peel grip with two couplings at 90° for measuring the bond strength of shoe soles at the toe, designed for DIN 4843 tests.

Brand: Universal Grip  |  Model: UGC-ST-350  |  ● Configured to order

  • Designed for sole tip peel bond strength tests such as DIN 4843

  • Wave jaws clamp the separated sole tip and hold flexible sole materials without tearing

  • Two female clevis couplings arranged at 90° make it easy to insert the shoe

  • Works on finished shoes and on sole assemblies

  • Can be combined with standard lower footwear holders

  • Coupling size, load rating and material are confirmed for your machine at quote

Standards: DIN 4843

Trusted by Global Companies

Sole tip peel grip for shoe bond strength tests to DIN 4843

The UGC-ST-350 is a peel grip for measuring how strongly a shoe sole is bonded at the toe. It is designed for sole tip peel bond tests such as DIN 4843 and is used by footwear manufacturers, safety shoe producers, sole adhesive developers and shoe component suppliers who want a measured force for toe bond strength instead of a pull by hand. The grip holds the separated tip of the sole, the testing machine pulls, and the force needed to peel the sole from the upper is recorded.

 

How the grip holds the sole tip

The toe is an awkward place to clamp. The separated tip is short and curved, and sole materials are flexible enough to slide out of flat jaw faces or tear along the clamp line. The UGC-ST-350 closes on the tip with wave jaws. The wave profile grips flexible sole materials without tearing them, so the separation runs along the bond between sole and upper and not through the specimen at the jaw.

The grip carries two female clevis couplings arranged at 90° to each other. This is what makes it practical on a production bench: the shoe can be inserted easily, and the grip is connected so that the sole is pulled at the correct angle without forcing the shoe into line with a single coupling.

 

What you can test

  • Finished shoes, tested at the toe of the sole

  • Sole assemblies taken from production or development

  • Safety shoes

  • Sole adhesives and bonding processes under evaluation

 

Setting it up on a testing machine

The UGC-ST-350 takes the peeled end of the sole. The shoe itself is held from below, and the grip can be combined with standard lower footwear holders; tell us what you already have and we will check the combination. The data sheet does not fix a coupling size, load rating or material for this grip. They are confirmed at quote to suit your frame and load cell, whether that is one of our universal testing machines or a machine already in your lab, and other connections are covered by our adapters. Dimensional drawings and 3D models are available on request.

 

Related footwear fixtures

Toe bond is one of several attachment tests on a shoe. The UGC-ST-370 uses pincer grips for upper-to-sole adhesion on cut sections of footwear, the UGC-ST-380 covers glued and nailed sole elements, and the UGC-ST-360 and UGC-ST-390 test heel bond strength on low heels and on medium and high heels. More single-purpose fixtures are listed under standard-specific test fixtures, and general-purpose peel hardware is on our peel fixtures page.

Tell us your shoe size range, your machine and its coupling, and whether you need a lower footwear holder, and we will configure the grip. Request a quote.

Product video

At a glance

  • Test type: Peel bond strength, sole tip

  • Standard: DIN 4843

  • Specimen: Footwear, sole at toe

  • Jaws: Wave jaws

  • Coupling: Two female clevis couplings at 90°; size on request

  • Max. load: On request

Shoe Sole Tip Bond Fixture DIN 4843 Specifications

TEST TYPE

Peel bond strength, sole tip

 

STANDARD

DIN 4843

 

SPECIMEN

Footwear, sole at toe

 

JAWS

Wave jaws

 

COUPLING

Two female clevis couplings at 90°; size on request

 

MAX. LOAD

On request

 

MATERIAL

On request

 

LOWER HOLDER

Can be combined with standard lower footwear holders

 

ORDERING INFORMATION

Specify shoe size range and machine coupling

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-ST-350

 

Models & Options

  • Sole tip peel grip — Wave-jaw grip with two female clevis couplings arranged at 90° (Specify at order)

  • Coupling size — Clevis couplings sized to the testing machine (On request)

  • Lower footwear holder — Standard lower holder for the shoe, used together with this grip (On request)

  • Custom versions — Versions for other shoe size ranges, couplings and adapters (On request)

What's Included

  • Sole tip peel grip with wave jaws

  • Two female clevis couplings arranged at 90° (size confirmed at order)

  • A lower footwear holder is not listed with this grip; ask for one with your quote if needed

  • Dimensional drawings or 3D models on request

Supported Test Standards

  • DIN 4843 — Peel bond strength of shoe soles at the toe

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-360 Low Heel Bond Strength Grips GOST 9136

UGC-ST-360 Low Heel Bond Strength Grips GOST 9136

Matched pair of needle-pin grips that clamp the heel and the shoe bottom for bond strength tests on low heels, designed

UGC-ST-370 Shoe Upper-to-Sole Bond Fixture

UGC-ST-370 Shoe Upper-to-Sole Bond Fixture

Upper and lower pincer grips with 0–10 mm jaw opening and a 273 mm self-aligning chain for upper-to-sole adhesion tests

UGC-ST-380 Shoe Sole Element Tensile Fixture GOST 9134

UGC-ST-380 Shoe Sole Element Tensile Fixture GOST 9134

Shoe-holding fixtures for the attachment strength of sole elements, in versions for GOST 9134 Fig. 3 and Fig. 4 (90° pee

UGC-ST-390 Medium and High Heel Bond Fixture GOST 9136

UGC-ST-390 Medium and High Heel Bond Fixture GOST 9136

Adjustable-angle heel bond fixture with a lower shoe cradle and an upper heel clamp for 75° and 90° peel tests on medium

Shoe Sole Tip Bond Fixture DIN 4843 FAQ

What does the UGC-ST-350 test?

The peel bond strength of a shoe sole at the toe. The separated sole tip is clamped in the grip, and the testing machine records the force needed to peel the sole from the upper.

 

Which standard is it designed for?

It is designed for sole tip peel bond tests such as DIN 4843. Your test method sets the speed, conditioning and evaluation; this page covers the hardware.

 

Why does the grip have two couplings at 90°?

The two female clevis couplings let you insert the shoe easily and connect the grip so the sole is pulled at the correct angle. You do not have to force the shoe into line with a single coupling.

 

Will the wave jaws tear the sole?

The wave jaws are there to hold flexible sole materials without tearing them. That keeps the separation at the bond and away from the clamp line.

 

What holds the shoe during the test?

A lower footwear holder. The grip can be combined with standard lower footwear holders; tell us what you have and we will confirm the combination or quote a holder.

 

What are the maximum load and coupling size?

Both are on request, as is the material. We confirm them against your machine and load cell at quote, and other connections are available through our adapters; contact us with your machine model.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page