Home › Products › Standard-Specific Test Fixtures › Shoe Sole Tip Bond Fixture DIN 4843





Shoe Sole Tip Bond Fixture DIN 4843
Wave-jaw peel grip with two couplings at 90° for measuring the bond strength of shoe soles at the toe, designed for DIN 4843 tests.
Brand: Universal Grip | Model: UGC-ST-350 | ● Configured to order
Designed for sole tip peel bond strength tests such as DIN 4843
Wave jaws clamp the separated sole tip and hold flexible sole materials without tearing
Two female clevis couplings arranged at 90° make it easy to insert the shoe
Works on finished shoes and on sole assemblies
Can be combined with standard lower footwear holders
Coupling size, load rating and material are confirmed for your machine at quote
Standards: DIN 4843
Trusted by Global Companies


























Sole tip peel grip for shoe bond strength tests to DIN 4843
The UGC-ST-350 is a peel grip for measuring how strongly a shoe sole is bonded at the toe. It is designed for sole tip peel bond tests such as DIN 4843 and is used by footwear manufacturers, safety shoe producers, sole adhesive developers and shoe component suppliers who want a measured force for toe bond strength instead of a pull by hand. The grip holds the separated tip of the sole, the testing machine pulls, and the force needed to peel the sole from the upper is recorded.
How the grip holds the sole tip
The toe is an awkward place to clamp. The separated tip is short and curved, and sole materials are flexible enough to slide out of flat jaw faces or tear along the clamp line. The UGC-ST-350 closes on the tip with wave jaws. The wave profile grips flexible sole materials without tearing them, so the separation runs along the bond between sole and upper and not through the specimen at the jaw.
The grip carries two female clevis couplings arranged at 90° to each other. This is what makes it practical on a production bench: the shoe can be inserted easily, and the grip is connected so that the sole is pulled at the correct angle without forcing the shoe into line with a single coupling.
What you can test
Finished shoes, tested at the toe of the sole
Sole assemblies taken from production or development
Safety shoes
Sole adhesives and bonding processes under evaluation
Setting it up on a testing machine
The UGC-ST-350 takes the peeled end of the sole. The shoe itself is held from below, and the grip can be combined with standard lower footwear holders; tell us what you already have and we will check the combination. The data sheet does not fix a coupling size, load rating or material for this grip. They are confirmed at quote to suit your frame and load cell, whether that is one of our universal testing machines or a machine already in your lab, and other connections are covered by our adapters. Dimensional drawings and 3D models are available on request.
Related footwear fixtures
Toe bond is one of several attachment tests on a shoe. The UGC-ST-370 uses pincer grips for upper-to-sole adhesion on cut sections of footwear, the UGC-ST-380 covers glued and nailed sole elements, and the UGC-ST-360 and UGC-ST-390 test heel bond strength on low heels and on medium and high heels. More single-purpose fixtures are listed under standard-specific test fixtures, and general-purpose peel hardware is on our peel fixtures page.
Tell us your shoe size range, your machine and its coupling, and whether you need a lower footwear holder, and we will configure the grip. Request a quote.
Shoe Sole Tip Bond Fixture DIN 4843 Specifications
TEST TYPE
Peel bond strength, sole tip
STANDARD
DIN 4843
SPECIMEN
Footwear, sole at toe
JAWS
Wave jaws
COUPLING
Two female clevis couplings at 90°; size on request
MAX. LOAD
On request
MATERIAL
On request
LOWER HOLDER
Can be combined with standard lower footwear holders
ORDERING INFORMATION
Specify shoe size range and machine coupling
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-350
Models & Options
Sole tip peel grip — Wave-jaw grip with two female clevis couplings arranged at 90° (Specify at order)
Coupling size — Clevis couplings sized to the testing machine (On request)
Lower footwear holder — Standard lower holder for the shoe, used together with this grip (On request)
Custom versions — Versions for other shoe size ranges, couplings and adapters (On request)
What's Included
Sole tip peel grip with wave jaws
Two female clevis couplings arranged at 90° (size confirmed at order)
A lower footwear holder is not listed with this grip; ask for one with your quote if needed
Dimensional drawings or 3D models on request
Supported Test Standards
DIN 4843 — Peel bond strength of shoe soles at the toe
Compatible Grips & Fixtures
UGC-ST-370 Shoe Upper-to-Sole Bond Fixture — Pincer grips for upper-to-sole adhesion on cut shoe sections
UGC-ST-380 Shoe Sole Element Tensile Fixture — Attachment strength of glued and nailed sole elements
Peel Fixtures — General-purpose peel test fixtures
Universal Testing Machines — Test frames; coupling and capacity confirmed at quote
Adapters — Couplings for other machine connections
Adhesives Testing — Fixtures and grips for adhesive bond tests
“Customer quote”
Related Equipment
UGC-ST-360 Low Heel Bond Strength Grips GOST 9136
Matched pair of needle-pin grips that clamp the heel and the shoe bottom for bond strength tests on low heels, designed
UGC-ST-370 Shoe Upper-to-Sole Bond Fixture
Upper and lower pincer grips with 0–10 mm jaw opening and a 273 mm self-aligning chain for upper-to-sole adhesion tests
UGC-ST-380 Shoe Sole Element Tensile Fixture GOST 9134
Shoe-holding fixtures for the attachment strength of sole elements, in versions for GOST 9134 Fig. 3 and Fig. 4 (90° pee
UGC-ST-390 Medium and High Heel Bond Fixture GOST 9136
Adjustable-angle heel bond fixture with a lower shoe cradle and an upper heel clamp for 75° and 90° peel tests on medium
Shoe Sole Tip Bond Fixture DIN 4843 FAQ
What does the UGC-ST-350 test?
The peel bond strength of a shoe sole at the toe. The separated sole tip is clamped in the grip, and the testing machine records the force needed to peel the sole from the upper.
Which standard is it designed for?
It is designed for sole tip peel bond tests such as DIN 4843. Your test method sets the speed, conditioning and evaluation; this page covers the hardware.
Why does the grip have two couplings at 90°?
The two female clevis couplings let you insert the shoe easily and connect the grip so the sole is pulled at the correct angle. You do not have to force the shoe into line with a single coupling.
Will the wave jaws tear the sole?
The wave jaws are there to hold flexible sole materials without tearing them. That keeps the separation at the bond and away from the clamp line.
What holds the shoe during the test?
A lower footwear holder. The grip can be combined with standard lower footwear holders; tell us what you have and we will confirm the combination or quote a holder.
What are the maximum load and coupling size?
Both are on request, as is the material. We confirm them against your machine and load cell at quote, and other connections are available through our adapters; contact us with your machine model.




