Home › Products › Standard-Specific Test Fixtures › Shoe Upper-to-Sole Bond Fixture





Shoe Upper-to-Sole Bond Fixture – ISO 17708
Upper and lower pincer grips with 0–10 mm jaw opening and a 273 mm self-aligning chain for upper-to-sole adhesion tests on footwear.
Brand: Universal Grip | Model: UGC-ST-370 | ● Configured to order
Designed for upper-to-sole adhesion tests such as ISO 17708 and ISO 20344
Upper and lower pincer grips, each with a 0–10 mm (0–0.39 in) jaw opening
273 mm (10.75 in) chain lets the grips self-align under load
Tests are made on cut sections of finished footwear with minimal preparation
Steel construction with a female clevis coupling for a Ø 20 mm pin
Fast clamping keeps up with production test rates
Standards: ISO 17708 · ISO 20344
Trusted by Global Companies


























Pincer grip fixture for upper-to-sole adhesion tests on footwear
The UGC-ST-370 is a bond strength fixture for measuring the force required to separate the upper from the sole of finished footwear. It is designed for upper-to-sole adhesion tests such as ISO 17708 and ISO 20344 and is used in footwear factories, shoe testing laboratories, safety footwear programs and sole adhesive development. The fixture consists of an upper and a lower pincer grip, each with a 0–10 mm (0–0.39 in) jaw opening, and a 273 mm (10.75 in) chain.
How the pincer grips work
The test is made on a cut section of the shoe, so very little preparation is needed beyond cutting the section. One pincer grip closes on the upper and the other on the sole. As the testing machine draws them apart the bond between the two opens, and the machine records the separating force. Both grips open from 0 to 10 mm, so the same fixture takes the edge of the upper and the edge of the sole.
The 273 mm chain allows the grips to self-align. A section cut from a shoe is never flat or symmetrical, and a rigid connection would load one side of the bond more than the other. With the chain in the load train the pull settles into line with the specimen. Clamping is fast, which counts when a production lab works through many pairs in a shift.
Construction and connection
Upper and lower pincer grips, jaw opening 0–10 mm on both
Chain length 273 mm
Steel construction
Female clevis coupling for a Ø 20 mm (0.79 in) pin
Maximum load on request
The Ø 20 mm clevis is a standard coupling size, and other machine connections are handled with our adapters. Because the data sheet gives the maximum load on request, we confirm the rating together with your frame and load cell at quote, whether you are fitting the fixture to one of our universal testing machines or to an existing machine. Ask us for a dimensional drawing or a 3D model if you want to check the fit beforehand.
Where it fits among footwear tests
Upper-to-sole adhesion looks at the main bond of the shoe. Other attachment points have their own hardware: the UGC-ST-350 tests the sole at the toe, the UGC-ST-380 tests glued and nailed sole elements, and the UGC-ST-360 and UGC-ST-390 test heel bond strength. For the upper material itself, the UGC-ST-620 measures finish adhesion on leather. All of them are listed with our standard-specific test fixtures.
Tell us the shoe types you test and your machine coupling, and we will confirm the fixture and its load rating for your setup. Request a quote.
Shoe Upper-to-Sole Bond Fixture Specifications
TEST TYPE
Upper-to-sole bond strength
STANDARDS
ISO 17708, ISO 20344
SPECIMEN
Cut sections of finished footwear
JAW OPENING
0–10 mm (both pincer grips)
CHAIN LENGTH
273 mm
COUPLING
Female clevis, Ø 20 mm pin
MATERIAL
Steel
MAX. LOAD
On request
ORDERING INFORMATION
Specify machine coupling and the shoe types to be tested
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-370
Models & Options
Upper-to-sole bond fixture — Upper and lower pincer grips, 0–10 mm jaw opening, with 273 mm chain (Specify at order)
Machine coupling — Other couplings and adapters in place of the Ø 20 mm clevis (On request)
Custom versions — Versions for other shoe types (On request)
What's Included
Upper pincer grip, jaw opening 0–10 mm
Lower pincer grip, jaw opening 0–10 mm
273 mm chain
Female clevis coupling for a Ø 20 mm pin
Dimensional drawings or 3D models on request
Supported Test Standards
ISO 17708 — Footwear, whole shoe: upper-to-sole adhesion
ISO 20344 — Test methods for footwear (personal protective equipment)
Compatible Grips & Fixtures
UGC-ST-350 Shoe Sole Tip Bond Fixture — Wave-jaw grip for sole bond strength at the toe
UGC-ST-380 Shoe Sole Element Tensile Fixture — Attachment strength of glued and nailed sole elements
UGC-ST-620 Leather Adhesion Test Fixture — 90° peel fixture for finish adhesion on leather
Universal Testing Machines — Test frames; load rating and fit confirmed at quote
Adapters — Couplings for other machine connections
Adhesives Testing — Fixtures and grips for adhesive bond tests
“Customer quote”
Related Equipment
UGC-ST-350 Shoe Sole Tip Bond Fixture DIN 4843
Wave-jaw peel grip with two couplings at 90° for measuring the bond strength of shoe soles at the toe, designed for DIN
UGC-ST-360 Low Heel Bond Strength Grips GOST 9136
Matched pair of needle-pin grips that clamp the heel and the shoe bottom for bond strength tests on low heels, designed
UGC-ST-380 Shoe Sole Element Tensile Fixture GOST 9134
Shoe-holding fixtures for the attachment strength of sole elements, in versions for GOST 9134 Fig. 3 and Fig. 4 (90° pee
UGC-ST-390 Medium and High Heel Bond Fixture GOST 9136
Adjustable-angle heel bond fixture with a lower shoe cradle and an upper heel clamp for 75° and 90° peel tests on medium
Shoe Upper-to-Sole Bond Fixture FAQ
What does the UGC-ST-370 measure?
The force required to separate the upper from the sole of finished footwear. It is designed for upper-to-sole adhesion tests such as ISO 17708 and ISO 20344.
Do I test the whole shoe?
The test is made on a cut section of the finished shoe, which keeps preparation to a minimum. One pincer grip holds the upper and the other holds the sole.
What thickness can the pincer grips hold?
Both the upper and the lower pincer grip have a jaw opening of 0–10 mm (0–0.39 in).
What is the chain for?
The 273 mm (10.75 in) chain lets the grips self-align, so the pull lines up with an uneven shoe section and does not load one side of the bond.
What is the maximum load?
The maximum load is on request. We confirm it at quote together with your machine and load cell.
How does it connect to my machine?
With a female clevis coupling for a Ø 20 mm pin. Other connections are available through our adapters; contact us with your machine model.