Home › Products › Standard-Specific Test Fixtures › Shoe Sole Element Tensile Fixture GOST 9134





Shoe Sole Element Tensile Fixture GOST 9134
Shoe-holding fixtures for the attachment strength of sole elements, in versions for GOST 9134 Fig. 3 and Fig. 4 (90° peel) and Fig. 5 (nailed).
Brand: Universal Grip | Model: UGC-ST-380 | ● Configured to order
Designed for sole element attachment tests such as GOST 9134
Fig. 3 and Fig. 4 versions hold the shoe for 90° peel tests on glued sole elements
Fig. 5 version tests nailed sole elements
Holds finished shoes securely during peeling
Combines with a standard upper grip that clamps the peeled element
Load rating, coupling and material are confirmed for your machine at quote
Standards: GOST 9134
Trusted by Global Companies


























GOST 9134 fixtures for the attachment strength of shoe sole elements
The UGC-ST-380 is a set of fixture versions for determining how strongly sole elements are attached to a shoe. It is designed for sole element attachment tests such as GOST 9134 and is used by footwear manufacturers, shoe component suppliers and footwear laboratories. The fixture holds the finished shoe while the testing machine pulls on the sole element and records the force needed to detach it.
Three versions, one for each test figure
GOST 9134 Fig. 3: 90° peel test fixture for glued sole elements.
GOST 9134 Fig. 4: 90° peel test fixture for glued sole elements.
GOST 9134 Fig. 5: fixture for nailed sole elements.
You order the version, or versions, that match the figures in your test plan. If you are not sure which figure applies to your construction, send us the shoe type and a note on how the sole element is fastened, and we will go through it with you before quoting.
How the test is set up
In the Fig. 3 and Fig. 4 versions the shoe is held so that a glued sole element is peeled away at 90°. Keeping the whole shoe still is the job of the fixture. A shoe is an irregular, flexible object, and if it shifts while the element is being pulled the peel angle drifts and one force trace can no longer be compared with the next. The Fig. 5 version is for sole elements that are nailed on instead of glued.
The UGC-ST-380 is the shoe-holding half of the setup. The peeled element is clamped in a standard upper grip that you combine with the fixture; a manual vise grip or a pneumatic grip can take that role. Tell us which grips you already own and we will confirm the match.
Load rating, coupling and material
For the GOST 9134 versions the data sheet gives the maximum load, the coupling and the material on request. We confirm all three at quote against the version you choose, your shoe size range and your machine, so the fixture arrives ready to pin onto your frame. That can be one of our universal testing machines or a machine you already have, and adapters cover other connections. Drawings or 3D models of the version you choose can be sent on request.
Related footwear fixtures
For the sole bond at the toe see the UGC-ST-350, and for upper-to-sole adhesion on cut shoe sections the UGC-ST-370. Heel attachment is covered by the UGC-ST-360 for low heels and the UGC-ST-390 for medium and high heels. General-purpose 90° and 180° hardware is on our peel fixtures page.
Tell us which GOST 9134 figure you need, your shoe size range and your machine coupling, and we will configure the fixture. Request a quote.
Product video
At a glance
Test type: 90° peel, tensile
Standard: GOST 9134, Fig. 3, 4, 5
Specimen: Shoe sole elements, glued or nailed
Versions: Fig. 3 and Fig. 4: 90° peel test fixture; Fig. 5: fixture for nailed sole elements
Upper grip: Combine with a standard upper grip for the peeled element
Max. load: On request
Shoe Sole Element Tensile Fixture GOST 9134 Specifications
TEST TYPE
90° peel, tensile
STANDARD
GOST 9134, Fig. 3, 4, 5
SPECIMEN
Shoe sole elements, glued or nailed
VERSIONS
Fig. 3 and Fig. 4: 90° peel test fixture; Fig. 5: fixture for nailed sole elements
UPPER GRIP
Combine with a standard upper grip for the peeled element
MAX. LOAD
On request
COUPLING
On request
MATERIAL
On request
ORDERING INFORMATION
Specify GOST 9134 figure, shoe size range and machine coupling
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-ST-380
Models & Options
GOST 9134 Fig. 3 — 90° peel test fixture (Specify at order)
GOST 9134 Fig. 4 — 90° peel test fixture (Specify at order)
GOST 9134 Fig. 5 — Fixture for nailed sole elements (Specify at order)
Upper grip — Standard upper grip to clamp the peeled sole element (On request)
Machine coupling — Coupling or adapter matched to the testing machine (On request)
What's Included
Shoe-holding fixture in the version ordered (GOST 9134 Fig. 3, Fig. 4 or Fig. 5)
The upper grip for the peeled element is a standard grip and is not listed with the fixture
Machine coupling confirmed at order
Dimensional drawings or 3D models on request
Supported Test Standards
GOST 9134 — Attachment strength of shoe sole elements (Fig. 3, 4 and 5)
Compatible Grips & Fixtures
Vise Grips — Manual upper grips for clamping the peeled sole element
Pneumatic Grips — Air-operated upper grips for higher test rates
UGC-ST-350 Shoe Sole Tip Bond Fixture — Wave-jaw grip for sole bond strength at the toe
UGC-ST-370 Shoe Upper-to-Sole Bond Fixture — Pincer grips for upper-to-sole adhesion
Peel Fixtures — General-purpose peel test fixtures
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-ST-350 Shoe Sole Tip Bond Fixture DIN 4843
Wave-jaw peel grip with two couplings at 90° for measuring the bond strength of shoe soles at the toe, designed for DIN
UGC-ST-360 Low Heel Bond Strength Grips GOST 9136
Matched pair of needle-pin grips that clamp the heel and the shoe bottom for bond strength tests on low heels, designed
UGC-ST-370 Shoe Upper-to-Sole Bond Fixture
Upper and lower pincer grips with 0–10 mm jaw opening and a 273 mm self-aligning chain for upper-to-sole adhesion tests
UGC-ST-390 Medium and High Heel Bond Fixture GOST 9136
Adjustable-angle heel bond fixture with a lower shoe cradle and an upper heel clamp for 75° and 90° peel tests on medium
Shoe Sole Element Tensile Fixture GOST 9134 FAQ
What does the UGC-ST-380 test?
The attachment strength of shoe sole elements. The fixture holds the shoe while the testing machine pulls on the element and records the force needed to detach it.
What is the difference between the three versions?
The Fig. 3 and Fig. 4 versions are 90° peel test fixtures for glued sole elements, and the Fig. 5 version is for nailed sole elements. Each is designed for the matching figure of GOST 9134.
Do I need all three versions?
Only the ones your test plan calls for. Tell us the GOST 9134 figure, or describe the shoe and how the sole element is fastened, and we will quote the right version.
Is the upper grip included?
The fixture is combined with a standard upper grip that clamps the peeled element. A manual vise grip or a pneumatic grip can be quoted with it.
What is the maximum load?
For the GOST 9134 versions the maximum load, the coupling and the material are on request. We confirm them at quote for the version and machine you specify.
What information do you need to quote?
The GOST 9134 figure, your shoe size range and your machine coupling. Contact us and we will confirm the fixture and any adapters.