Needle Tear Seam Strength Fixture ISO 17697

Needle tear fixture for the seam strength of footwear uppers, linings and insocks, used for ISO 17697 and EN 13572 Method A tests.

Brand: Universal Grip  |  Model: UGC-ST-630  |  ● Configured to order

  • Row of needles pierces the specimen next to the seam and carries the tearing load

  • Needle arrangement designed for ISO 17697 and EN 13572, Method A

  • Compact nickel-plated steel body, 0.19 kg (about 0.42 lb) without adapter

  • M8 thread connection, with adapters to common clevis couplings

  • Used with a small vise grip on the free specimen end (lower grip not included)

  • Yarn slippage version for woven fabrics available (ISO 12402-7 Fig. 1)

  • Temperature range 0 to +70 °C (32 to 158 °F); others on request

Standards: ISO 17697  ·  EN 13572  ·  ISO 12402-7

Trusted by Global Companies

Needle tear fixture for footwear seam strength

The UGC-ST-630 is a needle tear fixture for determining the seam strength of footwear uppers, linings and insocks. It is used for tests such as ISO 17697 Method A and EN 13572 Method A, where the question is how well the material itself holds a row of stitch holes when the seam is loaded. Footwear manufacturers, material suppliers and independent test labs use it to compare leathers, synthetics and lining materials before they go into production, and to keep an eye on incoming lots afterward.

 

How it works

A row of needles on the fixture pierces the specimen next to the seam. The free end of the specimen is held in a lower grip. The testing machine pulls the two apart in tension, the needles load the material, and the force needed to tear the material from the needles is recorded. Because the needle arrangement is part of the fixture and not something the operator sets up, each specimen is loaded through the same pattern and along the same line.

The body is compact, nickel-plated steel and weighs just 0.19 kg (about 0.42 lb) without an adapter, so it adds very little tare to a low-range load cell. The working temperature range is 0 to +70 °C (32 to 158 °F); other ranges are available on request.

 

Available versions

  • ISO 17697 / EN 13572 Method A: needle tear fixture for the seam strength of footwear uppers, linings and insocks.

  • ISO 12402-7 Fig. 1: needle tear fixture for the yarn slippage of woven fabrics. Specify this version at order if you test woven materials.

 

Mounting and lower grip

The fixture connects through an M8 thread, and adapters to common clevis couplings are available. No single maximum load is printed for the fixture, because the working limit depends on the coupling or adapter used; we confirm it against your coupling and load cell when we quote.

The lower grip is not part of the scope of supply. For the free end of the specimen we recommend a small 2.5 kN (about 562 lbf) vise grip with pyramid or smooth jaws. If you already own a suitable grip, tell us which one and we will check the fit. The fixture is normally run on a low-capacity frame such as a Galdabini benchtop universal testing machine.

 

Typical applications

  • Footwear uppers and linings

  • Insock seam testing

  • Yarn slippage of woven fabrics (ISO 12402-7 version)

  • Sports footwear quality control

Labs that test finished footwear as well as materials often pair this fixture with the UGC-ST-370 shoe upper-to-sole bond fixture. The rest of the family is listed with our standard-specific test fixtures.

Tell us your machine coupling, the lower grip you have or need, and whether you want the footwear or the yarn slippage version, and we will configure the fixture. Request a quote.

Product video

At a glance

  • Max. load: Depends on coupling/adapter used

  • Test type: Needle tear (seam strength), tension

  • Specimen: Footwear uppers, linings, insocks

  • Material: Steel, nickel-plated

  • Coupling: M8 thread; clevis adapters available

  • Temperature range: 0 to +70 °C (32 to 158 °F); others on request

Needle Tear Seam Strength Fixture ISO 17697 Specifications

MAX. LOAD

Depends on coupling/adapter used

 

TEST TYPE

Needle tear (seam strength), tension

 

SPECIMEN

Footwear uppers, linings, insocks

 

MATERIAL

Steel, nickel-plated

 

COUPLING

M8 thread; clevis adapters available

 

TEMPERATURE RANGE

0 to +70 °C (32 to 158 °F); others on request

 

WEIGHT

0.19 kg (0.42 lb) without adapter

 

SCOPE OF SUPPLY

1 fixture; lower grip not included

 

STANDARDS NAMED

ISO 17697 and EN 13572 (Method A); ISO 12402-7 Fig. 1 (optional version)

 

DRAWINGS

Dimensional drawing on the data sheet; certified drawings and 3D models on request

 

PART REF.

UGC-ST-630

 

Models & Options

  • ISO 17697 / EN 13572 Method A — Needle tear fixture for footwear seam strength (Specify at order)

  • ISO 12402-7 Fig. 1 — Needle tear fixture for yarn slippage of woven fabrics (Specify at order)

  • Clevis adapter — Adapter from the M8 thread to common clevis couplings (On request)

  • Lower grip — 2.5 kN vise grip with pyramid or smooth jaws recommended; ordered separately (On request)

  • Other temperature ranges — Versions for use outside 0 to +70 °C (On request)

What's Included

  • 1 needle tear fixture in the version ordered

  • M8 thread connection

  • Lower grip is not included and is ordered separately

  • Clevis adapters are quoted separately on request

  • Certified drawings and 3D models available on request

Supported Test Standards

  • ISO 17697 — Footwear uppers, lining and insocks: seam strength (Method A)

  • EN 13572 — Footwear uppers, lining and insocks: seam strength (Method A)

  • ISO 12402-7 — Yarn slippage of woven fabrics, Fig. 1 needle fixture (optional version)

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-ST-370 Shoe Upper-to-Sole Bond Fixture

UGC-ST-370 Shoe Upper-to-Sole Bond Fixture

Upper and lower pincer grips with 0–10 mm jaw opening and a 273 mm self-aligning chain for upper-to-sole adhesion tests

UGC-ST-870 Egg Tray Tensile Fixture

UGC-ST-870 Egg Tray Tensile Fixture

Wide-jaw tensile fixture for molded pulp egg trays and formed packaging, with 290 mm jaws, nylon clamping bars and a 100

UGC-ST-690 Fabric Bending Stiffness Fixture

UGC-ST-690 Fabric Bending Stiffness Fixture

Bench-top cantilever fixture for the bending stiffness of nonwovens and textile fabrics, with a sample opening adjustabl

UGC-ST-490 Finch Wet Tensile Fixture ISO 12625-5

UGC-ST-490 Finch Wet Tensile Fixture ISO 12625-5

Finch device for wet tensile strength of paper, tissue paper and tissue products, with stainless steel bar and aluminum

Needle Tear Seam Strength Fixture ISO 17697 FAQ

What does the UGC-ST-630 measure?

The force needed to tear footwear upper, lining or insock material away from a row of needles placed next to the seam. It is used for seam strength tests such as ISO 17697 Method A and EN 13572 Method A.

 

Is the lower grip included?

No. The scope of supply is one fixture. A small 2.5 kN vise grip with pyramid or smooth jaws is recommended for the free end of the specimen.

 

What is the maximum load?

It depends on the coupling or adapter used, so no single figure is printed for the fixture. We confirm the working load against your coupling and load cell at quote.

 

How does it connect to my testing machine?

Through an M8 thread. Adapters to common clevis couplings are available; tell us your machine model and coupling size.

 

Can it test yarn slippage of woven fabrics?

Yes, in a separate version. A needle tear fixture for yarn slippage of woven fabrics to ISO 12402-7 Fig. 1 is available; specify it at order.

 

What temperature range can it be used in?

0 to +70 °C (32 to 158 °F) as standard. Other ranges are available on request.

 

Need help configuring a standard-specific test fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page