Shoulder Grips for Small Specimens – Ø 6 and 8.1 mm Bores

Hardened shoulder grips for small round specimens with button or shoulder heads, in Ø 8.1 mm and Ø 6 mm bores with radiused seats.

Brand: Universal Grip  |  Model: UGC-SH-130  |  ● Configured to order

  • Radiused seats match the shoulder of the specimen head for even bearing

  • Two bore sizes: Ø 8.1 mm (2 mm radius) and Ø 6 mm (1.5 mm radius)

  • Threaded collars and thumb screws for quick specimen change

  • Load introduced through the head, never by clamping the gauge section

  • Hardened, nickel-plated steel for wear resistance

  • Also suited to small fine ceramic tensile specimens

Downloads and standards

Trusted by Global Companies

Shoulder grips for small round tensile specimens

Small round specimens with shouldered or button-head ends are common in materials research, sub-size metal testing and fine ceramics. Wedge jaws are a poor fit for them: they can damage the short gauge section, and their alignment is not good enough for the small cross-sections involved. The UGC-SH-130 shoulder grips hold the specimen by its head instead. They are made for research labs, metallurgy labs and anyone testing miniature or sub-size specimens.

 

How it works

The specimen shank passes through a bored hole in the grip, and its head seats against a radiused shoulder at the bottom of the bore. The radius matches the fillet under the specimen head, so the contact is spread evenly instead of concentrated on an edge. A threaded collar with thumb screws closes the grip around the head and lets the operator change specimens quickly without tools. Because load is introduced through the head, the gauge section is never clamped or marked.

 

Bore sizes

  • Hole Ø 8.1 mm (0.319 in), seat radius 2 mm

  • Hole Ø 6 mm (0.236 in), seat radius 1.5 mm

The bore has to clear the specimen shank while the head bears on the radius, so pick the size from your specimen drawing. If your shank or head dimensions sit between the two, tell us and we will advise.

 

Construction and coupling

The grips are hardened, nickel-plated steel for wear resistance at the seat. The machine connection is a male clevis Ø 35 mm (1.38 in); other connections are handled with our adapters. Operation is manual, using the threaded collar and thumb screws. The maximum load is confirmed at quote based on your specimen.

 

Typical applications

Small metal tensile specimens, miniature and sub-size specimens, materials research, and small fine ceramic specimens. For standard-shaped ceramic specimens, see our fine ceramics tensile fixture. For larger button-head specimens with interchangeable inserts, see the button head grips with split inserts, and for full-size threaded and shouldered metal specimens browse our shoulder grips.

 

Machine fit

Small specimens are typically tested on Galdabini bench-top universal testing machines. Add an extensometer when you need strain on a short gauge length.

Tell us the specimen shank diameter and head geometry, the expected maximum load and your machine coupling, and we will confirm the bore size. Request a quote.

Product video

At a glance

  • Test type: Tensile test of shouldered round specimens

  • Specimen hole: Ø 8.1 mm or Ø 6 mm

  • Seat radius: 2 mm (Ø 8.1 mm hole) or 1.5 mm (Ø 6 mm hole)

  • Max. load: On request

  • Material: Steel, hardened, nickel-plated

  • Coupling: Male clevis, Ø 35 mm

Shoulder Grips for Small Specimens Specifications

TEST TYPE

Tensile test of shouldered round specimens

 

SPECIMEN HOLE

Ø 8.1 mm or Ø 6 mm

 

SEAT RADIUS

2 mm (Ø 8.1 mm hole) or 1.5 mm (Ø 6 mm hole)

 

MAX. LOAD

On request

 

MATERIAL

Steel, hardened, nickel-plated

 

COUPLING

Male clevis, Ø 35 mm

 

OPERATION

Manual, threaded collar with thumb screws

 

PART REF.

UGC-SH-130

 

Models & Options

  • Hole Ø 8.1 mm — Seat radius 2 mm (Specify at order)

  • Hole Ø 6 mm — Seat radius 1.5 mm (Specify at order)

  • Coupling adapter — For machines without a male clevis Ø 35 mm connection (On request)

What's Included

  • Shoulder grips with the bore size ordered

  • Threaded collars with thumb screws

  • Male clevis Ø 35 mm couplings

Supported Test Standards

Standards list

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SH-120 Welded Car Part Shoulder Grip

UGC-SH-120 Welded Car Part Shoulder Grip

Split upper chuck on a universal joint plus a split ring holder on a T-slot base, for pulling welded automotive assembli

UGC-SH-140 Carbon and Graphite Tensile Fixture

UGC-SH-140 Carbon and Graphite Tensile Fixture

Carrier and insert set that seats shaped carbon and graphite specimens for tensile stress-strain tests to ASTM C749, in

UGC-SH-110 Fine Ceramics Tensile Fixture ISO 15490

UGC-SH-110 Fine Ceramics Tensile Fixture ISO 15490

Steel tensile fixtures for monolithic fine ceramics to ASTM C1273 and ISO 15490, with seats for GIRI, Fig. 15 and Karlsr

UGC-SH-150 Rubber Adhesion Test Fixture GOST 209

UGC-SH-150 Rubber Adhesion Test Fixture GOST 209

Cylindrical carriers and 25 mm disc inserts, held by a knurled cross pin, for tear-off adhesion tests of rubber-to-metal

Shoulder Grips for Small Specimens FAQ

What specimens do these grips take?

Small round specimens with shouldered or button-head ends. The shank goes through the bore and the head seats on a radiused shoulder.

 

Which bore size do I need?

Ø 8.1 mm with a 2 mm seat radius, or Ø 6 mm with a 1.5 mm seat radius. Choose from your specimen's shank diameter and head fillet.

 

How are specimens changed?

A threaded collar with thumb screws closes the grip around the head, so specimens are changed by hand without tools.

 

Can I test ceramic specimens?

Yes, the grips also suit small fine ceramic tensile specimens. For standard ceramic shapes, see the fine ceramics tensile fixture.

 

What is the coupling?

A male clevis Ø 35 mm (1.38 in). If your crosshead has a different connection, we supply a matching adapter.

 

Need help configuring a shoulder and button head grip?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page