top of page

Home  ›  Products  ›  Shoulder and Button Head Grips  ›  Fine Ceramics Tensile Fixture ISO 15490

UGC-SH-110 fine ceramics tensile fixture ISO 15490 for shaped-end ceramic specimens by Universal Grip
UGC-SH-110 fine ceramics tensile fixture ISO 15490 for shaped-end ceramic specimens by Universal Grip
UGC-SH-110 Fine Ceramics Tensile Fixture ISO 15490 by Universal Grip, view 2
UGC-SH-110 Fine Ceramics Tensile Fixture ISO 15490 by Universal Grip, view 3
UGC-SH-110 Fine Ceramics Tensile Fixture ISO 15490 by Universal Grip, view 4

Fine Ceramics Tensile Fixture ISO 15490 – 10 kN

Steel tensile fixtures for monolithic fine ceramics to ASTM C1273 and ISO 15490, with seats for GIRI, Fig. 15 and Karlsruhe specimen shapes.

Brand: Universal Grip  |  Model: UGC-SH-110  |  ● Configured to order

  • For ambient-temperature tensile tests to ASTM C1273 and ISO 15490

  • Specimen-specific seats introduce load axially and keep bending low

  • Three versions for the GIRI, ASTM C1273 Fig. 15 and Karlsruhe specimen shapes

  • Each version rated to 10 kN (2,248 lbf) for high-strength ceramics

  • Steel construction with standard clevis couplings, others via adapter

Standards: ASTM C1273  ·  ISO 15490

Trusted by Global Companies

Tensile testing of monolithic fine ceramics

Advanced ceramics are strong but unforgiving: a small bending component during a tensile test can cut the measured strength sharply and widen the scatter. Clamping them in serrated jaws is not an option. The UGC-SH-110 fixtures hold shaped ceramic specimens by their ends in matching seats so that load goes in along the specimen axis. They are built for tensile strength tests on monolithic fine (advanced technical) ceramics at ambient temperature, for tests such as ASTM C1273 and ISO 15490, and are used in ceramic material development, aerospace and energy component work, and research laboratories.

See our complete ASTM C1273 guide for specimen preparation, procedure and calculations; this page covers the fixture hardware.

 

How it works

Each standard specimen geometry has its own shaped ends. The fixture for that geometry has seats that match those ends, so the specimen drops in and bears on the seat surfaces rather than being squeezed. As the crosshead moves, the seats pull the specimen along its axis, minimizing the bending that brittle materials cannot tolerate. Specimen insertion is manual.

 

Versions

  • GIRI specimen shape (ASTM C1273 and ISO 15490): male clevis with Ø 30 mm pin hole.

  • ASTM C1273 Fig. 15 shape: female clevis for a Ø 20 mm pin.

  • Univ. Karlsruhe specimen shape (ASTM C1273 and ISO 15490): female clevis for a Ø 15.9 mm (5/8 in) pin.

All three are steel and rated to 10 kN (2,248 lbf). For a machine with a different connection, use one of our adapters.

 

Choosing the right version

The choice follows your specimen. If your lab already machines one of the three geometries, order the matching fixture. If you are setting up a new program, the specimen drawing in your chosen standard, and your machine's coupling, will usually decide it. We can advise when the specimen supplier and test lab use different shapes.

 

Machine fit and accessories

The 10 kN rating matches a Galdabini 10 kN bench-top universal testing machine. For strain and modulus measurement on small ceramic gauge sections, pair the fixture with a clip-on extensometer or a non-contact video extensometer. For small round shoulder-head specimens, also see our shoulder grips for small specimens.

Tell us the specimen geometry (GIRI, ASTM C1273 Fig. 15 or Karlsruhe shape) and your machine coupling, and we will quote the fixture. Request a quote.

Product video

At a glance

  • Max. load: 10 kN

  • Test type: Tensile strength of monolithic fine ceramics

  • Specimen: Shaped-end specimens to ASTM C1273 / ISO 15490

  • Material: Steel

  • Coupling: Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm, or male clevis Ø 30 mm; others via adapter

  • Temperature: Ambient

Fine Ceramics Tensile Fixture ISO 15490 Specifications

MAX. LOAD

10 kN

 

TEST TYPE

Tensile strength of monolithic fine ceramics

 

SPECIMEN

Shaped-end specimens to ASTM C1273 / ISO 15490

 

MATERIAL

Steel

 

COUPLING

Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm, or male clevis Ø 30 mm; others via adapter

 

TEMPERATURE

Ambient

 

OPERATION

Manual specimen insertion

 

STANDARDS

ISO 15490, ASTM C1273

 

PART REF.

UGC-SH-110

 

Models & Options

  • GIRI specimen shape — ASTM C1273 and ISO 15490; male clevis, Ø 30 mm pin hole; 10 kN (Specify at order)

  • ASTM C1273 Fig. 15 shape — Female clevis, Ø 20 mm pin; 10 kN (Specify at order)

  • Univ. Karlsruhe specimen shape — ASTM C1273 and ISO 15490; female clevis, Ø 15.9 mm (5/8 in) pin; 10 kN (Specify at order)

  • Coupling adapter — For machines with other couplings (On request)

What's Included

  • Fine ceramics tensile fixture for the specimen shape ordered

  • Clevis coupling per version

  • Drawings and 3D models on request

Supported Test Standards

  • ASTM C1273 — Tensile strength of monolithic advanced ceramics at ambient temperature

  • ISO 15490 — Fine ceramics – tensile strength of monolithic ceramics at room temperature

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SH-100 Adjustable Double Hook Grip

UGC-SH-100 Adjustable Double Hook Grip

Compact lower grip with two screw-adjusted hook arms for pulling loops, rings and eyelets, connected by an M12 male thre

UGC-SH-120 Welded Car Part Shoulder Grip

UGC-SH-120 Welded Car Part Shoulder Grip

Split upper chuck on a universal joint plus a split ring holder on a T-slot base, for pulling welded automotive assembli

UGC-SH-090 Liquid-Applied Membrane Adhesion Fixture EN 14891

UGC-SH-090 Liquid-Applied Membrane Adhesion Fixture EN 14891

Guided fixture that opens a crack beneath liquid-applied waterproofing for tiles to EN 14891 A.8, with a tensile adhesio

UGC-SH-130 Shoulder Grips for Small Specimens

UGC-SH-130 Shoulder Grips for Small Specimens

Hardened shoulder grips for small round specimens with button or shoulder heads, in Ø 8.1 mm and Ø 6 mm bores with radiu

Fine Ceramics Tensile Fixture ISO 15490 FAQ

Which standards is this fixture used for?

Ambient-temperature tensile tests on monolithic fine ceramics such as ASTM C1273 and ISO 15490. Our ASTM C1273 guide covers specimens, procedure and calculations.

 

Why not use wedge grips for ceramics?

Ceramics are brittle and sensitive to bending. Seating shaped specimen ends in matching holders keeps the load axial and avoids clamping damage.

 

Which specimen shapes are covered?

Three: the GIRI shape, the ASTM C1273 Fig. 15 shape and the Univ. Karlsruhe shape. Each has its own fixture.

 

What is the load rating?

Every version is rated to 10 kN (2,248 lbf).

 

Can it be used at high temperature?

These fixtures are for ambient-temperature testing.

 

How do I measure strain?

Pair the fixture with an extensometer or a video extensometer.

 

Need help configuring a shoulder and button head grip?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page