top of page

Home  ›  Products  ›  Shoulder and Button Head Grips  ›  Rubber Adhesion Test Fixture GOST 209

UGC-SH-150 rubber adhesion test fixture GOST 209 with carriers, disc inserts and cross pin by Universal Grip
UGC-SH-150 rubber adhesion test fixture GOST 209 with carriers, disc inserts and cross pin by Universal Grip
UGC-SH-150 Rubber Adhesion Test Fixture GOST 209 by Universal Grip, view 2
Product photo 3
Product photo 4

Rubber Adhesion Test Fixture GOST 209 – 25 mm Discs

Cylindrical carriers and 25 mm disc inserts, held by a knurled cross pin, for tear-off adhesion tests of rubber-to-metal and glue bonds to GOST 209.

Brand: Universal Grip  |  Model: UGC-SH-150  |  ● Configured to order

  • For tear-off bond strength tests to GOST 209, Fig. 2

  • Disc inserts with a Ø 25 mm (0.98 in) test surface

  • Inserts drop into carriers and lock with a knurled cross pin

  • Fast specimen change between tests, no tools required

  • Nickel-plated steel carriers and inserts for corrosion protection

  • Supplied with one pair of carriers and inserts

Standards: GOST 209

Trusted by Global Companies

Tear-off adhesion testing of rubber and glue bonds

Anti-vibration mounts, bushings and many other rubber-to-metal parts rely on the bond between rubber and steel. The tear-off test checks that bond directly by pulling two bonded discs apart. The UGC-SH-150 fixture measures the adhesion strength of rubber to metal and of glue bonds by the tear-off method of GOST 209. It is used by rubber compounders, bonding agent and adhesive developers and makers of rubber-to-metal parts.

 

How it works

The specimen is bonded between two disc inserts, each with a 25 mm (0.98 in) diameter test surface. After curing, the two inserts drop into cylindrical carriers, one on the upper and one on the lower side of the machine, and are secured with a knurled cross pin. The crosshead then pulls the carriers apart and loads the bond in tension until it fails. The peak force divided by the disc area gives the adhesion strength, and the failure surface shows whether the bond failed in the rubber, at the interface or in the adhesive.

The cross pin is pushed in and pulled out by hand, so a bonded pair can be loaded, tested and replaced in moments. That suits a lab running a series of specimens from one batch of compound or adhesive.

 

Construction and coupling

  • Cylindrical carriers and disc inserts, steel, nickel-plated

  • Test surface Ø 25 mm

  • Knurled cross pin retention

  • Female clevis coupling for a 20 mm (0.79 in) pin; others via adapters

The fixture is supplied with one pair of carriers and inserts. Most labs order extra disc inserts so several specimens can be bonded and cured at the same time while the fixture stays on the machine. The maximum load is confirmed at quote.

 

Typical applications

Rubber-to-metal bonded parts, anti-vibration mounts, adhesive and glue development, and rubber compound quality control. For adhesive bond tests to GOST 14760 and related methods, see the adhesive bond tensile fixture; for coatings, see the coating bond strength fixture.

 

Machine fit

Bond strength tests on 25 mm discs are normally run on a Galdabini bench-top universal testing machine; we confirm the rating against your expected bond strength. More fixtures for rubber are on our elastomer testing page.

Tell us how many additional disc inserts you need, the expected maximum load and your machine coupling. Request a quote.

Product video

At a glance

  • Test type: Tensile adhesion (tear-off) of rubber and glue bonds

  • Test surface: Ø 25 mm

  • Max. load: On request

  • Material: Steel, nickel-plated

  • Coupling: Female clevis, Ø 20 mm pin; others via adapter

  • Scope of delivery: 1 pair of carriers and inserts

Rubber Adhesion Test Fixture GOST 209 Specifications

TEST TYPE

Tensile adhesion (tear-off) of rubber and glue bonds

 

TEST SURFACE

Ø 25 mm

 

MAX. LOAD

On request

 

MATERIAL

Steel, nickel-plated

 

COUPLING

Female clevis, Ø 20 mm pin; others via adapter

 

SCOPE OF DELIVERY

1 pair of carriers and inserts

 

OPERATION

Manual, pin-retained inserts

 

STANDARDS

GOST 209

 

PART REF.

UGC-SH-150

 

Models & Options

  • GOST 209 adhesion fixture — 1 pair of carriers and disc inserts, Ø 25 mm test surface (Specify at order)

  • Additional disc inserts — Extra inserts for bonding several specimens at once (Specify at order)

  • Coupling adapter — For machines without a 20 mm clevis (On request)

What's Included

  • 1 pair of cylindrical carriers with female clevis coupling

  • 1 pair of disc inserts with Ø 25 mm test surface

  • Knurled cross pins for insert retention

  • Additional inserts available separately

Supported Test Standards

  • GOST 209 — Rubber and glue – adhesion strength to metal by tear-off method

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SH-140 Carbon and Graphite Tensile Fixture

UGC-SH-140 Carbon and Graphite Tensile Fixture

Carrier and insert set that seats shaped carbon and graphite specimens for tensile stress-strain tests to ASTM C749, in

UGC-SH-160 Steel Fastener Grip ISO 898-1 1000 kN

UGC-SH-160 Steel Fastener Grip ISO 898-1 1000 kN

Heavy-duty insert holder for tensile tests on full-size bolts, screws and studs up to 1000 kN, mounted in a larger wedge

UGC-SH-130 Shoulder Grips for Small Specimens

UGC-SH-130 Shoulder Grips for Small Specimens

Hardened shoulder grips for small round specimens with button or shoulder heads, in Ø 8.1 mm and Ø 6 mm bores with radiu

UGC-SH-180 Plating Embrittlement Shoulder Grip

UGC-SH-180 Plating Embrittlement Shoulder Grip

Shoulder grip with hardened inserts for ASTM F519 type 1a.2 notched round specimens, for sustained-load hydrogen embritt

Rubber Adhesion Test Fixture GOST 209 FAQ

What does this fixture test?

The adhesion strength of rubber to metal and of glue bonds, by the tear-off method of GOST 209.

 

How big is the bonded area?

Each disc insert has a Ø 25 mm (0.98 in) test surface.

 

How are the inserts held?

They drop into cylindrical carriers and are locked with a knurled cross pin, so specimens are changed by hand.

 

Should I order extra inserts?

Usually yes. One pair of carriers and inserts is supplied; extra inserts let you bond and cure several specimens while the fixture stays mounted.

 

What coupling does it use?

A female clevis for a 20 mm (0.79 in) pin; machines with other couplings take an adapter.

 

Need help configuring a shoulder and button head grip?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page