Home › Products › Puncture Fixtures › Dental Ceramic Biaxial Flexure Fixture ISO 6872





Dental Ceramic Biaxial Flexure Fixture ISO 6872
Piston-on-three-balls fixture with tungsten carbide piston for biaxial flexural strength of dental ceramic discs to ISO 6872, rated 2.5 kN.
Brand: Universal Grip | Model: UGC-PF-040 | ● Configured to order
Piston-on-three-balls arrangement per ISO 6872
Three hardened steel support balls, Ø 3.175 mm (0.125 in)
Tungsten carbide loading piston, Ø 1.4 mm (0.055 in)
Stainless steel 304 body rated 2.5 kN (562 lbf)
Usable from -70 to +280 °C (-94 to 536 °F) inside a chamber
Version for ceramic substrates to ASTM F394 available
Standards: ISO 6872 · ASTM F394
Trusted by Global Companies


























Biaxial flexure fixture for dental ceramics
The UGC-PF-040 is a piston-on-three-balls fixture for measuring the flexural strength of dental ceramics used in all-ceramic and metal-ceramic restorations, according to ISO 6872. Dental material manufacturers, dental lab R&D groups and university research labs use biaxial flexure because it loads a thin disc away from its edges, so the result reflects the material rather than edge chips left from cutting or grinding. The same stainless steel fixture is also available set up for ceramic substrates to ASTM F394.
How it works
A disc specimen rests on three hardened steel balls of Ø 3.175 mm (0.125 in) arranged on a support circle. A tungsten carbide piston of Ø 1.4 mm (0.055 in) presses on the center of the disc from above until it fractures. Three-point support keeps the disc stable even if it is not perfectly flat, and the carbide piston holds its contact geometry over many tests on hard materials such as zirconia. The fracture load, disc thickness and support geometry are then used to calculate biaxial flexural strength.
Built for chamber testing
The body is stainless steel 1.4301 (304) and is rated 2.5 kN (562 lbf). It can be used from -70 to +280 °C (-94 to 536 °F) inside an environmental chamber, so strength can be measured on conditioned specimens without moving them to a different fixture. At 1.23 kg (2.7 lb) it is easy to place and center in a chamber. The standard coupling is a female clevis with a Ø 15.9 mm (5/8 in) pin; others are available on request or through adapters. The fixture is supplied with its three support balls.
Versions
ISO 6872: dental ceramics
ASTM F394: ceramic substrates, modulus of rupture
When ordering, specify the standard, your disc specimen diameter and the machine coupling.
Typical applications
Dental ceramics and zirconia
Restoration materials
Ceramic substrates
Dental lab R&D
Machine fit
With a 2.5 kN rating, the fixture suits a Galdabini 2.5 kN or 5 kN benchtop UTM, and its full capacity is also within the range of a Mark-10 F-series motorized tester (up to 1,500 lbF). For three- and four-point bending of bar specimens, see our bend testing fixtures.
Tell us the standard, disc diameter and machine coupling, and we will configure the fixture: request a quote.
Dental Ceramic Biaxial Flexure Fixture ISO 6872 Specifications
MAX. LOAD
2.5 kN
TEST TYPE
Biaxial flexure (piston on three balls)
SUPPORT
3 hardened steel balls, Ø 3.175 mm
PISTON
Ø 1.4 mm, tungsten carbide
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin; others on request
MATERIAL
Stainless steel 1.4301 (304)
TEMPERATURE RANGE
-70 to +280 °C
WEIGHT
1.23 kg
SCOPE OF SUPPLY
1 fixture incl. 3 balls
DRAWINGS
Dimensional drawing on data sheet; certified drawings and 3D models on request
PART REF.
UGC-PF-040
Models & Options
ISO 6872 version — Dental ceramics (Specify at order)
ASTM F394 version — Ceramic substrates, modulus of rupture (Specify at order)
Disc specimen diameter — Support set up for your disc size (Specify at order)
Machine coupling — Female clevis Ø 15.9 mm standard; others (On request)
What's Included
1 biaxial flexure fixture in stainless steel
3 hardened steel support balls, Ø 3.175 mm
Tungsten carbide loading piston, Ø 1.4 mm
Supported Test Standards
ISO 6872 — Dentistry, ceramic materials (biaxial flexural strength)
ASTM F394 — Biaxial flexure strength (modulus of rupture) of ceramic substrates
Compatible Grips & Fixtures
2.5 kN Benchtop UTM — Galdabini frame matched to the fixture rating
5 kN Benchtop UTM — Galdabini frame with headroom
Environmental Chambers — Test from -70 to +280 °C
Bend Testing Fixtures — Three- and four-point flexure for bars
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-PF-030 Geomembrane Index Puncture Fixture
Ring clamp with 45 mm opening and hardened 8 mm probe for index puncture tests on geomembranes and geosynthetics to ASTM
UGC-PF-050 Geotextile Static Puncture Fixture
50 kN CBR-type static puncture fixture with sample positioning tool for geotextiles and geogrids, used for ASTM D6241 an
UGC-PF-020 Bi-Metal Coin Core Push-Out Fixture
Compression fixture that punches the center pill out of a bi-metal coin or token and records the push-out shear force ho
UGC-PF-060 Ball Burst Puncture Fixture ISO 9073-5
Ring clamp with 44.45 mm opening and 25.4 mm ball probe for bursting strength of knits, nonwovens and coated fabrics, ra
Dental Ceramic Biaxial Flexure Fixture ISO 6872 FAQ
What is a piston-on-three-balls test?
A disc rests on three balls and is loaded at its center by a small piston, so it bends biaxially. It is the biaxial flexure arrangement used in ISO 6872 for dental ceramics.
What are the support and piston dimensions?
Three hardened steel balls of Ø 3.175 mm and a tungsten carbide piston of Ø 1.4 mm.
Can it be used inside a temperature chamber?
Yes. The stainless steel fixture is usable from -70 to +280 °C in an environmental chamber.
Is there a version for ceramic substrates?
Yes, a version for ASTM F394 modulus-of-rupture testing of ceramic substrates is available. Specify it when ordering.
What is the maximum load?
2.5 kN (562 lbf), which suits a Galdabini 2.5 kN benchtop UTM or larger frame.
What do I need to specify?
The standard (ISO 6872 or ASTM F394), your disc specimen diameter and the machine coupling.