Home › Products › Puncture Fixtures › Ball Burst Puncture Fixture ISO 9073-5





Ball Burst Puncture Fixture ISO 9073-5 – 1 in Ball
Ring clamp with 44.45 mm opening and 25.4 mm ball probe for bursting strength of knits, nonwovens and coated fabrics, rated 20 kN or 50 kN.
Brand: Universal Grip | Model: UGC-PF-060 | ● Configured to order
Clamp ring opening Ø 44.45 mm (1.75 in) with Ø 25.4 mm (1 in) ball probe
20 kN (4,496 lbf) or 50 kN (11,240 lbf) rating depending on coupling size
Usable from -40 to +80 °C (-40 to 176 °F) for conditioned testing
Used for ISO 9073-5, ASTM D3787, ASTM D6797, ASTM D751 and GB 19976 tests
Version for coated fabrics to ISO 3303-1 and a small-specimen version
Nickel-plated steel for corrosion resistance
Standards: ASTM D3787 · ASTM D6797 · ISO 9073-5 · ISO 3303-1
Trusted by Global Companies


























Ball burst fixture for textiles, nonwovens and coated fabrics
The UGC-PF-060 measures the bursting strength of textiles, nonwovens and coated fabrics by pushing a steel ball through a clamped specimen. It is used for tests to ISO 9073-5, ASTM D3787 and ASTM D6797, and for related methods including ASTM D751 and GB 19976. Knits and nonwovens stretch in many directions at once, so a ball burst result often says more about them than a strip or grab test. Textile mills, nonwoven producers, coated fabric manufacturers and medical textile labs use it for routine QC and product development. See our complete ASTM D3787 guide and ASTM D6797 guide for specimen preparation, procedure and calculations.
How it works
The specimen is clamped between upper and lower rings with a Ø 44.45 mm (1.75 in) opening. A Ø 25.4 mm (1 in) ball probe, driven by the crosshead, pushes into the fabric until it bursts. The maximum force is reported as the bursting strength, and the displacement at burst shows how far the fabric distended first.
Ratings and construction
The rating follows the coupling: 20 kN (4,496 lbf) with a female clevis of Ø 15.9 mm (5/8 in) or Ø 20 mm, and 50 kN (11,240 lbf) with a Ø 31.8 mm (1-1/4 in) clevis. Other couplings are on request or via adapters. The nickel-plated steel fixture weighs 7.5 kg (16.5 lb), comes with its probe, and is usable from -40 to +80 °C (-40 to 176 °F), so it can run inside an environmental chamber for conditioned tests. Other temperature ranges are on request.
Versions
Standard: ring Ø 44.45 mm, ball Ø 25.4 mm, for ISO 9073-5 and ASTM D3787
ISO 3303-1: ring Ø 45 mm, plunger Ø 25.2 mm (0.992 in), 20 kN, 7.3 kg, for rubber- or plastics-coated fabrics
Small specimen: hole Ø 11.1 mm (0.437 in), punch Ø 6.35 mm (0.25 in), for limited sample material
Typical applications
Knitted fabrics
Nonwoven fabrics
Rubber- or plastic-coated fabrics
Medical and hygiene textiles
Machine fit
The 20 kN version suits a Galdabini 25 kN benchtop UTM; the 50 kN version a 50 kN or 100 kN frame. Lighter knits and nonwovens that burst within 1,500 lbF can also run on a Mark-10 F-series motorized tester. For leather, see the UGC-PF-070; for tissue paper, the UGC-PF-110.
Tell us the standard, your machine coupling and any special temperature range, and we will configure the fixture: request a quote.
Ball Burst Puncture Fixture ISO 9073-5 Specifications
TEST TYPE
Ball burst
MAX. LOAD
20 kN (Ø 15.9 or 20 mm clevis); 50 kN (Ø 31.8 mm clevis)
RING OPENING
Ø 44.45 mm (1.75 in)
BALL PROBE
Ø 25.4 mm (1 in)
COUPLING
Female clevis Ø 15.9 mm (5/8 in), Ø 20 mm or Ø 31.8 mm (1-1/4 in); others on request
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
-40 to +80 °C (others on request)
WEIGHT
7.5 kg
SCOPE OF SUPPLY
1 fixture incl. probe
DRAWINGS
Dimensional drawings on data sheet; certified drawings and 3D models on request
PART REF.
UGC-PF-060
Models & Options
Standard version — Ring Ø 44.45 mm, ball Ø 25.4 mm; ISO 9073-5, ASTM D3787 (Specify at order)
ISO 3303-1 version — Ring Ø 45 mm, plunger Ø 25.2 mm, 20 kN, 7.3 kg (Specify at order)
Small specimen version — Hole Ø 11.1 mm, punch Ø 6.35 mm (On request)
Coupling / rating — Ø 15.9 or 20 mm clevis (20 kN) or Ø 31.8 mm clevis (50 kN) (Specify at order)
Special temperature range — Beyond -40 to +80 °C (On request)
What's Included
1 ball burst fixture with upper and lower clamp rings
Ball probe (or plunger, for the ISO 3303-1 version)
Coupling per the rating ordered
Supported Test Standards
ASTM D3787 — Bursting strength of textiles, constant-rate-of-traverse ball burst
ASTM D6797 — Bursting strength of fabrics, constant-rate-of-extension ball burst
ISO 9073-5 — Nonwovens, resistance to mechanical penetration (ball burst)
ISO 3303-1 — Rubber- or plastics-coated fabrics, burst strength (version)
Compatible Grips & Fixtures
25 kN Benchtop UTM — Galdabini frame for the 20 kN version
Environmental Chambers — Conditioned burst tests from -40 to +80 °C
UGC-PF-110 Tissue Paper Ball Burst Fixture — Ball burst for dry and wet tissue
Textiles Testing — Fabric tensile, tear and burst setups
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-PF-070 Leather Ball Burst Fixture ISO 3379
Compact 2 kN ball burst fixture that records distension at grain crack and at burst, showing whether leather will surviv
UGC-PF-110 Tissue Paper Ball Burst Fixture ISO 12625-9
Stainless steel ball burst fixture with water tray for dry and wet tissue, pneumatic (500 N) or manual (10 kN) clamping,
UGC-PF-200 Shade Net Ball Burst Fixture
Ball burst fixture for HDPE woven shade nets: a Ø 50 mm plastic ball pushes through net clamped over a Ø 102 mm opening
UGC-PF-050 Geotextile Static Puncture Fixture
50 kN CBR-type static puncture fixture with sample positioning tool for geotextiles and geogrids, used for ASTM D6241 an
Ball Burst Puncture Fixture ISO 9073-5 FAQ
Which standards is this ball burst fixture used for?
ISO 9073-5, ASTM D3787 and ASTM D6797, plus related methods such as ASTM D751 and GB 19976. See our ASTM D3787 guide and ASTM D6797 guide for the procedures.
What are the ring and ball sizes?
The clamp ring opening is Ø 44.45 mm (1.75 in) and the ball probe is Ø 25.4 mm (1 in).
Is it rated 20 kN or 50 kN?
Either. A Ø 15.9 mm or Ø 20 mm clevis gives 20 kN; a Ø 31.8 mm clevis gives 50 kN.
Can I test coated fabrics to ISO 3303-1?
Yes, with the ISO 3303-1 version: Ø 45 mm ring and Ø 25.2 mm plunger, rated 20 kN.
Can it be used in a temperature chamber?
Yes. It is usable from -40 to +80 °C (-40 to 176 °F) in an environmental chamber; other ranges on request.
What if I only have small samples?
A small-specimen version with an Ø 11.1 mm hole and Ø 6.35 mm punch is available.