Home › Products › Puncture Fixtures › Geomembrane Index Puncture Fixture





Geomembrane Index Puncture Fixture – ASTM D4833
Ring clamp with 45 mm opening and hardened 8 mm probe for index puncture tests on geomembranes and geosynthetics to ASTM D4833.
Brand: Universal Grip | Model: UGC-PF-030 | ● Configured to order
Ring clamp with a 45 ± 0.025 mm (1.772 ± 0.001 in) inside diameter
Hardened flat-ended probe, Ø 8 ± 0.1 mm (0.315 ± 0.004 in)
20 kN (4,496 lbf) or 50 kN (11,240 lbf) rating, set by the coupling you choose
Light to handle: 3.3 kg lower part incl. adapter, 0.68 kg probe
Nickel-plated steel for corrosion resistance
Also used for GOST R 56586 and NF P 84-507 puncture tests
Standards: ASTM D4833 · GOST R 56586 · NF P 84-507
Trusted by Global Companies


























Index puncture fixture for geomembranes and geosynthetics
The UGC-PF-030 is a ring clamp and probe set for the index puncture test on geomembranes, geotextiles and related products. It is dimensioned for ASTM D4833 and is also used for tests to GOST R 56586 and NF P 84-507. Geosynthetics manufacturers, liner QC labs and civil engineering test labs use it to compare products and to check production lots against a specified minimum puncture resistance. See our complete ASTM D4833 guide for specimen preparation, procedure and calculations.
How it works
The specimen is clamped between two rings with an inside diameter of 45 ± 0.025 mm (1.772 ± 0.001 in) and an outside diameter of 100 mm (3.937 in). A hardened, flat-ended probe of Ø 8 ± 0.1 mm (0.315 ± 0.004 in), driven by the crosshead, pushes through the center of the clamped area. The maximum force before the probe breaks through is recorded as the index puncture resistance. Pre-cutting bolt holes in the specimen is recommended, so slick membranes are held positively in the clamp and cannot draw in under load.
Two load ratings
The rating follows the coupling you select:
20 kN (4,496 lbf) with a female clevis of Ø 15.9 mm (5/8 in) or Ø 20 mm
50 kN (11,240 lbf) with a female clevis of Ø 31.8 mm (1-1/4 in)
Other couplings are available through adapters. The lower part weighs 3.3 kg (7.3 lb) including its adapter and the probe 0.68 kg (1.5 lb), so the fixture goes on and off the machine quickly between test programs. Nickel-plated steel resists corrosion, and the standard temperature range is 0 to +70 °C (32 to 158 °F), with other ranges on request.
Typical applications
Geomembranes and liners
Geotextiles and geosynthetics
Landfill and civil engineering projects
Roofing membranes
Machine fit
The 20 kN version pairs naturally with a Galdabini 25 kN benchtop UTM; choose the 50 kN version for a 50 kN or 100 kN frame when you test thick or reinforced products. For the larger CBR-style static puncture test on geotextiles, see the UGC-PF-050 geotextile static puncture fixture. The full range is on our puncture fixtures page.
Tell us your machine coupling and any special temperature range, and we will configure the fixture: request a quote.
ASTM D4833 index puncture test
At a glance
Test type: Index puncture
Max. load: 20 kN (Ø 15.9 or 20 mm clevis); 50 kN (Ø 31.8 mm clevis)
Clamping ring: Inside Ø 45 ± 0.025 mm (1.772 ± 0.001 in), outside Ø 100 mm (3.937 in)
Probe: Ø 8 ± 0.1 mm (0.315 ± 0.004 in), hardened
Coupling: Female clevis Ø 15.9 mm (5/8 in), Ø 20 mm or Ø 31.8 mm (1-1/4 in); others via adapter
Material: Steel, nickel-plated
Geomembrane Index Puncture Fixture Specifications
TEST TYPE
Index puncture
MAX. LOAD
20 kN (Ø 15.9 or 20 mm clevis); 50 kN (Ø 31.8 mm clevis)
CLAMPING RING
Inside Ø 45 ± 0.025 mm (1.772 ± 0.001 in), outside Ø 100 mm (3.937 in)
PROBE
Ø 8 ± 0.1 mm (0.315 ± 0.004 in), hardened
COUPLING
Female clevis Ø 15.9 mm (5/8 in), Ø 20 mm or Ø 31.8 mm (1-1/4 in); others via adapter
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
0 to +70 °C (others on request)
WEIGHT
3.3 kg lower part incl. adapter; 0.68 kg probe
SCOPE OF SUPPLY
1 fixture incl. probe
DRAWINGS
Dimensional drawings on data sheet; certified drawings and 3D models on request
PART REF.
UGC-PF-030
Models & Options
20 kN version — Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm (Specify at order)
50 kN version — Female clevis Ø 31.8 mm (1-1/4 in) (Specify at order)
Other couplings — Connection to non-standard machines via adapter (On request)
Special temperature range — Beyond 0 to +70 °C (On request)
What's Included
1 fixture: upper and lower clamping rings with adapter
Hardened Ø 8 mm probe
Coupling per the version ordered (20 kN or 50 kN)
Supported Test Standards
ASTM D4833 — Index puncture resistance of geomembranes and related products
GOST R 56586 — Geomembrane puncture resistance (Russian national method)
NF P 84-507 — Geomembrane puncture resistance (French national method)
Compatible Grips & Fixtures
25 kN Benchtop UTM — Galdabini frame for the 20 kN version
50 kN Benchtop UTM — Galdabini frame for the 50 kN version
UGC-PF-050 Geotextile Static Puncture Fixture — CBR static puncture for geotextiles
Puncture Testing — Puncture test setups and methods
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-PF-050 Geotextile Static Puncture Fixture
50 kN CBR-type static puncture fixture with sample positioning tool for geotextiles and geogrids, used for ASTM D6241 an
UGC-PF-020 Bi-Metal Coin Core Push-Out Fixture
Compression fixture that punches the center pill out of a bi-metal coin or token and records the push-out shear force ho
UGC-PF-040 Dental Ceramic Biaxial Flexure Fixture ISO 6872
Piston-on-three-balls fixture with tungsten carbide piston for biaxial flexural strength of dental ceramic discs to ISO
UGC-PF-010 Textile Elasticity Fixture ISO 20932-2
Ring clamp and hemispherical probe that stretch a clamped fabric in every direction at once to measure multiaxial elasti
Geomembrane Index Puncture Fixture FAQ
Which test is the UGC-PF-030 for?
The index puncture test on geomembranes and related products, with the 45 mm ring opening and 8 mm probe used in ASTM D4833. Our ASTM D4833 guide covers specimens, procedure and calculations.
Is it 20 kN or 50 kN?
Both are available. The rating follows the coupling: 20 kN with a Ø 15.9 mm or Ø 20 mm clevis, 50 kN with a Ø 31.8 mm clevis.
How do I stop the geomembrane slipping in the clamp?
Pre-cut bolt holes in the specimen so it is held positively between the rings; this is recommended on the data sheet.
Can it be used for other national standards?
Yes. It is also used for puncture tests to GOST R 56586 and NF P 84-507.
What temperature range does it cover?
0 to +70 °C (32 to 158 °F) as standard; other ranges are available on request.
What is the difference from the UGC-PF-050?
The PF-030 is a small-probe index test. The UGC-PF-050 runs the larger CBR-style static puncture test on geotextiles at up to 50 kN.