Home › Products › Puncture Fixtures › Packaging Puncture Resistance Fixture EN 14477





Packaging Puncture Resistance Fixture EN 14477
Needle puncture fixture with interchangeable 0.8 mm round or 3 mm flat needles for packaging films, pouches and laminates to EN 14477.
Brand: Universal Grip | Model: UGC-PF-080 | ● Configured to order
Set up for the DIN EN 14477 packaging puncture test
Supplied with a Ø 0.8 mm (0.031 in) round needle
3 mm wide flat needles and custom needle shapes available
Needles sit in a separate, interchangeable needle holder
Takes specimens up to 3 mm (0.118 in) thick
Steel body rated 10 kN (2,248 lbf)
Standards: EN 14477
Trusted by Global Companies


























Needle puncture fixture for flexible packaging to EN 14477
The UGC-PF-080 measures the force a needle needs to puncture packaging and flexible packaging materials, according to DIN EN 14477. Sharp corners of contents, bone fragments in meat packs, staples or careless handling all test a pack's puncture resistance in real life. Film producers, converters and medical packaging manufacturers use this test to compare structures, qualify suppliers and release production lots of films, pouches, blister materials and foils.
How it works
The specimen is clamped in the lower holder. A needle, carried in a needle holder on the upper adapter, is driven down by the crosshead until it penetrates the material, and the testing machine records the force needed to puncture. The holder accepts specimens up to 3 mm (0.118 in) thick, which covers thin monofilms as well as heavier laminates and multilayer pouch stock.
Needles
The fixture is supplied with a Ø 0.8 mm (0.031 in) round needle. A flat needle 3 mm wide is available for a blade-like point, and needles can be made to a customer-specified shape when your product or customer spec calls for a particular geometry. Because the needle sits in a separate needle holder, you can order a spare holder without a needle and keep a second needle type mounted, then change between them in seconds rather than re-seating a needle each time.
Standard: fixture with Ø 0.8 mm round needle
Needle holder: spare holder without needle
Flat needle: 3 mm wide
Custom needle: shape to customer specification
Construction
The body is steel and the fixture is rated 10 kN (2,248 lbf). It connects with a female clevis and Ø 15.9 mm (5/8 in) pin; other couplings are on request or through adapters. The standard temperature range is 0 to +70 °C (32 to 158 °F), with others on request.
Typical applications
Flexible packaging films
Blister and pouch materials
Medical packaging
Laminates and foils
Machine fit
The 10 kN rating is the fixture's own limit; your machine only needs to cover the puncture forces of the materials you test. Films and thin laminates suit a Mark-10 F-series motorized tester (100 to 1,500 lbF), and a Galdabini benchtop UTM handles heavier structures. If you need pneumatic clamping for EN 14477, see the EN 14477 version of the UGC-PF-100. Packaging peel and seal fixtures are on our peel page.
Tell us the needle type, your specimen thickness and machine coupling, and we will configure the fixture: request a quote.
Packaging Puncture Resistance Fixture EN 14477 Specifications
MAX. LOAD
10 kN
TEST TYPE
Needle puncture
MAX. SPECIMEN THICKNESS
3 mm
NEEDLE
Ø 0.8 mm round (standard); 3 mm flat optional
NEEDLE MOUNTING
Interchangeable needle holder on upper adapter
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin; others on request
BODY
Steel
TEMPERATURE RANGE
0 to +70 °C (others on request)
SCOPE OF SUPPLY
1 fixture incl. Ø 0.8 mm needle
DRAWINGS
Dimensional drawings on data sheet; certified drawings and 3D models on request
PART REF.
UGC-PF-080
Models & Options
Standard — Fixture with Ø 0.8 mm round needle (Specify at order)
Needle holder — Spare holder without needle (Specify at order)
Flat needle — 3 mm wide (Specify at order)
Custom needle — Shape to customer specification (On request)
Machine coupling — Female clevis Ø 15.9 mm standard; others (On request)
What's Included
1 puncture fixture with lower specimen holder and upper needle holder
Ø 0.8 mm round needle
Flat needles, spare holders and custom needles are ordered separately
Supported Test Standards
EN 14477 — Packaging, flexible packaging material, puncture resistance
Compatible Grips & Fixtures
Motorized Tensile Testers — Mark-10 F-series frames for film puncture forces
Benchtop UTMs — Galdabini frames for heavier laminates
UGC-PF-100 Pneumatic Barrier Film Penetration Fixture — Pneumatic clamping, EN 14477 version available
Plastics Testing — Film tensile and tear setups
Peel Fixtures — Seal and peel tests on packaging
“Customer quote”
Related Equipment
UGC-PF-100 Pneumatic Barrier Film Penetration Fixture
Pneumatically clamped fixture for ASTM F1306 slow rate penetration of barrier films, with 5 kN clamping at 7 bar for sli
UGC-PF-070 Leather Ball Burst Fixture ISO 3379
Compact 2 kN ball burst fixture that records distension at grain crack and at burst, showing whether leather will surviv
UGC-PF-090 Small Sample Slow Rate Penetration Fixture
Manually clamped film penetration fixture based on ASTM F1306, sized for strips up to 50 mm wide or discs up to 64 mm in
UGC-PF-060 Ball Burst Puncture Fixture ISO 9073-5
Ring clamp with 44.45 mm opening and 25.4 mm ball probe for bursting strength of knits, nonwovens and coated fabrics, ra
Packaging Puncture Resistance Fixture EN 14477 FAQ
What does EN 14477 measure?
The puncture resistance of packaging and flexible packaging materials: the force needed for a needle to penetrate the specimen.
Which needle comes with the fixture?
A Ø 0.8 mm round needle. A 3 mm flat needle and custom shapes are available.
How thick can the specimen be?
Up to 3 mm (0.118 in).
Can I switch needles quickly?
Yes. Needles sit in a separate needle holder, and a spare holder can be ordered so a second needle type stays mounted.
What is the maximum load?
10 kN (2,248 lbf). Your machine only needs to cover the puncture forces of your materials, often a Mark-10 motorized tester is enough.
Is there a pneumatically clamped option?
Yes, the UGC-PF-100 is available in an EN 14477 version with pneumatic clamping and a Ø 10 mm opening.