top of page

Home  ›  Products  ›  Puncture Fixtures  ›  Packaging Puncture Resistance Fixture EN 14477

UGC-PF-080 packaging puncture resistance fixture with 0.8 mm needle for EN 14477 by Universal Grip
UGC-PF-080 packaging puncture resistance fixture with 0.8 mm needle for EN 14477 by Universal Grip
UGC-PF-080 Packaging Puncture Resistance Fixture EN 14477 by Universal Grip, view 2
Product photo 3
Product photo 4

Packaging Puncture Resistance Fixture EN 14477

Needle puncture fixture with interchangeable 0.8 mm round or 3 mm flat needles for packaging films, pouches and laminates to EN 14477.

Brand: Universal Grip  |  Model: UGC-PF-080  |  ● Configured to order

  • Set up for the DIN EN 14477 packaging puncture test

  • Supplied with a Ø 0.8 mm (0.031 in) round needle

  • 3 mm wide flat needles and custom needle shapes available

  • Needles sit in a separate, interchangeable needle holder

  • Takes specimens up to 3 mm (0.118 in) thick

  • Steel body rated 10 kN (2,248 lbf)

Standards: EN 14477

Trusted by Global Companies

Needle puncture fixture for flexible packaging to EN 14477

The UGC-PF-080 measures the force a needle needs to puncture packaging and flexible packaging materials, according to DIN EN 14477. Sharp corners of contents, bone fragments in meat packs, staples or careless handling all test a pack's puncture resistance in real life. Film producers, converters and medical packaging manufacturers use this test to compare structures, qualify suppliers and release production lots of films, pouches, blister materials and foils.

 

How it works

The specimen is clamped in the lower holder. A needle, carried in a needle holder on the upper adapter, is driven down by the crosshead until it penetrates the material, and the testing machine records the force needed to puncture. The holder accepts specimens up to 3 mm (0.118 in) thick, which covers thin monofilms as well as heavier laminates and multilayer pouch stock.

 

Needles

The fixture is supplied with a Ø 0.8 mm (0.031 in) round needle. A flat needle 3 mm wide is available for a blade-like point, and needles can be made to a customer-specified shape when your product or customer spec calls for a particular geometry. Because the needle sits in a separate needle holder, you can order a spare holder without a needle and keep a second needle type mounted, then change between them in seconds rather than re-seating a needle each time.

  • Standard: fixture with Ø 0.8 mm round needle

  • Needle holder: spare holder without needle

  • Flat needle: 3 mm wide

  • Custom needle: shape to customer specification

 

Construction

The body is steel and the fixture is rated 10 kN (2,248 lbf). It connects with a female clevis and Ø 15.9 mm (5/8 in) pin; other couplings are on request or through adapters. The standard temperature range is 0 to +70 °C (32 to 158 °F), with others on request.

 

Typical applications

  • Flexible packaging films

  • Blister and pouch materials

  • Medical packaging

  • Laminates and foils

 

Machine fit

The 10 kN rating is the fixture's own limit; your machine only needs to cover the puncture forces of the materials you test. Films and thin laminates suit a Mark-10 F-series motorized tester (100 to 1,500 lbF), and a Galdabini benchtop UTM handles heavier structures. If you need pneumatic clamping for EN 14477, see the EN 14477 version of the UGC-PF-100. Packaging peel and seal fixtures are on our peel page.

Tell us the needle type, your specimen thickness and machine coupling, and we will configure the fixture: request a quote.

Product video

At a glance

  • Max. load: 10 kN

  • Test type: Needle puncture

  • Max. specimen thickness: 3 mm

  • Needle: Ø 0.8 mm round (standard); 3 mm flat optional

  • Needle mounting: Interchangeable needle holder on upper adapter

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

Packaging Puncture Resistance Fixture EN 14477 Specifications

MAX. LOAD

10 kN

 

TEST TYPE

Needle puncture

 

MAX. SPECIMEN THICKNESS

3 mm

 

NEEDLE

Ø 0.8 mm round (standard); 3 mm flat optional

 

NEEDLE MOUNTING

Interchangeable needle holder on upper adapter

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

 

BODY

Steel

 

TEMPERATURE RANGE

0 to +70 °C (others on request)

 

SCOPE OF SUPPLY

1 fixture incl. Ø 0.8 mm needle

 

DRAWINGS

Dimensional drawings on data sheet; certified drawings and 3D models on request

 

PART REF.

UGC-PF-080

 

Models & Options

  • Standard — Fixture with Ø 0.8 mm round needle (Specify at order)

  • Needle holder — Spare holder without needle (Specify at order)

  • Flat needle — 3 mm wide (Specify at order)

  • Custom needle — Shape to customer specification (On request)

  • Machine coupling — Female clevis Ø 15.9 mm standard; others (On request)

What's Included

  • 1 puncture fixture with lower specimen holder and upper needle holder

  • Ø 0.8 mm round needle

  • Flat needles, spare holders and custom needles are ordered separately

Supported Test Standards

  • EN 14477 — Packaging, flexible packaging material, puncture resistance

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-PF-100 Pneumatic Barrier Film Penetration Fixture

UGC-PF-100 Pneumatic Barrier Film Penetration Fixture

Pneumatically clamped fixture for ASTM F1306 slow rate penetration of barrier films, with 5 kN clamping at 7 bar for sli

UGC-PF-070 Leather Ball Burst Fixture ISO 3379

UGC-PF-070 Leather Ball Burst Fixture ISO 3379

Compact 2 kN ball burst fixture that records distension at grain crack and at burst, showing whether leather will surviv

UGC-PF-090 Small Sample Slow Rate Penetration Fixture

UGC-PF-090 Small Sample Slow Rate Penetration Fixture

Manually clamped film penetration fixture based on ASTM F1306, sized for strips up to 50 mm wide or discs up to 64 mm in

UGC-PF-060 Ball Burst Puncture Fixture ISO 9073-5

UGC-PF-060 Ball Burst Puncture Fixture ISO 9073-5

Ring clamp with 44.45 mm opening and 25.4 mm ball probe for bursting strength of knits, nonwovens and coated fabrics, ra

Packaging Puncture Resistance Fixture EN 14477 FAQ

What does EN 14477 measure?

The puncture resistance of packaging and flexible packaging materials: the force needed for a needle to penetrate the specimen.

 

Which needle comes with the fixture?

A Ø 0.8 mm round needle. A 3 mm flat needle and custom shapes are available.

 

How thick can the specimen be?

Up to 3 mm (0.118 in).

 

Can I switch needles quickly?

Yes. Needles sit in a separate needle holder, and a spare holder can be ordered so a second needle type stays mounted.

 

What is the maximum load?

10 kN (2,248 lbf). Your machine only needs to cover the puncture forces of your materials, often a Mark-10 motorized tester is enough.

 

Is there a pneumatically clamped option?

Yes, the UGC-PF-100 is available in an EN 14477 version with pneumatic clamping and a Ø 10 mm opening.

 

Need help configuring a puncture fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page