Home › Products › Puncture Fixtures › Tissue Paper Ball Burst Fixture ISO 12625-9





Tissue Paper Ball Burst Fixture ISO 12625-9
Stainless steel ball burst fixture with water tray for dry and wet tissue, pneumatic (500 N) or manual (10 kN) clamping, to ISO 12625-9.
Brand: Universal Grip | Model: UGC-PF-110 | ● Configured to order
Set up for the DIN EN ISO 12625-9 tissue ball burst test
Pneumatic clamping for repeatable specimen restraint, or manual version
Water tray catches drips during wet strength tests; 50 mm deep tray optional
Stainless steel construction for wet testing
Pneumatic versions for single- and double-column machines
Pneumatic 500 N (112 lbf); manual version rated 10 kN (2,248 lbf)
Standards: ISO 12625-9
Trusted by Global Companies


























Ball burst fixture for dry and wet tissue products
The UGC-PF-110 determines the ball burst strength of tissue paper and tissue products according to DIN EN ISO 12625-9. Toilet tissue, kitchen towel, facial tissue and hygiene products all need to hold together when pushed through by a finger or a hand, often when wet. Paper mills, converters and hygiene product manufacturers use the ball burst test for grade development and for routine reel and finished-product QC.
How it works
The tissue sample is clamped over a ring, either pneumatically or manually, and a ball probe driven by the crosshead pushes through it until it bursts. The peak force is the ball burst strength. For wet tests, a tray under the clamp catches water dripping from the soaked sample, so it does not run onto the machine base or into the load cell. The whole fixture is stainless steel, so repeated wet testing does not leave it corroded.
Versions
Pneumatic, single column: 500 N (112 lbf), 13 kg (28.7 lb)
Pneumatic, double column: with adapter extension, 500 N, 13.5 kg (29.8 lb)
Manual: 10 kN (2,248 lbf), 10 kg (22 lb)
Manual, deep tray: 50 mm (1.97 in) deep tray
Choosing pneumatic or manual
Pneumatic clamping applies the same restraint to every sample, which is what you want for high-volume QC on a mill floor where many operators share one tester. It also speeds up loading, which matters with wet samples that start to dry and change as soon as they come out of the water. The manual version needs no air supply and carries a 10 kN rating, which suits labs that test heavier towel grades or want one fixture for occasional use. The deep-tray manual version holds more water for longer wet test series.
Every version is supplied with its water tray and connects with a female clevis and Ø 15.9 mm (5/8 in) pin; other couplings are on request or via adapters. The standard temperature range is 0 to +70 °C (32 to 158 °F).
Typical applications
Tissue and towel paper
Wet strength testing
Hygiene products
Paper mill quality control
Machine fit
The 500 N pneumatic single-column version suits single-column frames such as a Mark-10 F-series motorized tester. On a double-column Galdabini benchtop UTM, order the version with the adapter extension. For fabrics and nonwovens, see the UGC-PF-060 ball burst fixture.
Tell us whether you want pneumatic or manual clamping and whether your machine is single- or double-column, and we will configure the fixture: request a quote.
Tissue Paper Ball Burst Fixture ISO 12625-9 Specifications
MAX. LOAD
500 N (pneumatic); 10 kN (manual)
TEST TYPE
Ball burst
OPERATION
Pneumatic or manual clamping
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin; others on request
MATERIAL
Stainless steel
TEMPERATURE RANGE
0 to +70 °C (others on request)
WEIGHT
13 kg (pneumatic); 13.5 kg (with extension); 10 kg (manual)
SCOPE OF SUPPLY
1 fixture incl. water tray
DRAWINGS
Dimensional drawings on data sheet; certified drawings and 3D models on request
PART REF.
UGC-PF-110
Models & Options
Pneumatic, single column — 500 N, 13 kg (Specify at order)
Pneumatic, double column — With adapter extension, 500 N, 13.5 kg (Specify at order)
Manual — 10 kN, 10 kg (Specify at order)
Manual, deep tray — 50 mm deep water tray (Specify at order)
What's Included
1 ball burst fixture in the version ordered
Water tray (50 mm deep on the deep-tray version)
Adapter extension on the double-column version
Supported Test Standards
ISO 12625-9 — Tissue paper and tissue products, ball burst strength
Compatible Grips & Fixtures
Motorized Tensile Testers — Single-column Mark-10 F-series frames for the 500 N version
Benchtop UTMs — Galdabini double-column frames with the extension version
UGC-PF-060 Ball Burst Puncture Fixture — Ball burst for textiles and nonwovens
Tensile Grips — Grips for tissue and paper strip tensile tests
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-PF-060 Ball Burst Puncture Fixture ISO 9073-5
Ring clamp with 44.45 mm opening and 25.4 mm ball probe for bursting strength of knits, nonwovens and coated fabrics, ra
UGC-PF-100 Pneumatic Barrier Film Penetration Fixture
Pneumatically clamped fixture for ASTM F1306 slow rate penetration of barrier films, with 5 kN clamping at 7 bar for sli
UGC-PF-120 Fabric Stiffness Puncture Fixture
Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at
UGC-PF-090 Small Sample Slow Rate Penetration Fixture
Manually clamped film penetration fixture based on ASTM F1306, sized for strips up to 50 mm wide or discs up to 64 mm in
Tissue Paper Ball Burst Fixture ISO 12625-9 FAQ
What does ISO 12625-9 measure?
The ball burst strength of tissue paper and tissue products: the force needed to push a ball through a clamped sample.
Can I test wet tissue?
Yes. A water tray catches drips during wet tests, and the fixture is stainless steel throughout. A 50 mm deep tray version is available.
Pneumatic or manual: which should I choose?
Pneumatic clamping (500 N) gives identical restraint and fast loading for high-volume QC. The manual version (10 kN) needs no air supply.
Does it fit a double-column machine?
Yes, order the pneumatic version with the adapter extension for double-column machines.
How heavy is it?
13 kg (pneumatic), 13.5 kg (with extension) or 10 kg (manual).
Which tester suits the pneumatic version?
Its 500 N (112 lbf) rating suits a single-column Mark-10 F-series motorized tester.