Fabric Stiffness Puncture Fixture – ASTM D4032 Circular Bend

Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at once, for ASTM D4032.

Brand: Universal Grip  |  Model: UGC-PF-120  |  ● Configured to order

  • Ø 38.1 mm (1.5 in) orifice on an 80 mm (3.15 in) high platform

  • Flat-ended plunger, Ø 25.4 mm (1 in)

  • One peak force reflects bending resistance in all directions

  • Compact 2.2 kg (4.9 lb) fixture with clevis coupling

  • Nickel-plated steel, rated 20 kN (4,496 lbf)

  • Reduced-size variant with Ø 19 mm orifice for small samples

Standards: ASTM D4032

Trusted by Global Companies

Circular bend stiffness fixture for fabrics

The UGC-PF-120 measures the stiffness of fabrics by the circular bend procedure of ASTM D4032. Instead of bending a strip in one direction, the test pushes a flat fabric specimen through a round orifice, so it folds in all directions at once. The resulting peak force is used to assess hand and drape. Textile mills, nonwoven producers, coated fabric makers and apparel developers use it to compare finishes, check that a softening treatment has worked, or hold a fabric to a stiffness specification. See our complete ASTM D4032 guide for specimen preparation, procedure and calculations.

 

How it works

The fabric is laid flat over a platform with a Ø 38.1 mm (1.5 in) orifice. A flat-ended plunger of Ø 25.4 mm (1 in), driven by the crosshead, pushes the specimen down through the orifice, folding it into the opening. The platform stands 80 mm (3.15 in) high, which leaves room below for the folded fabric to pass through. The maximum force during the stroke reflects the combined bending resistance of the fabric in every direction, so a single number captures stiffness that would otherwise need separate warp and weft cantilever tests.

 

Construction

The fixture is nickel-plated steel for corrosion resistance and weighs 2.2 kg (4.9 lb). It is rated 20 kN (4,496 lbf), far above the forces a circular bend test produces, so the fixture itself is never the limit. It connects with a female clevis and Ø 15.9 mm (5/8 in) pin; other couplings are on request or through adapters. The standard temperature range is 0 to +70 °C (32 to 158 °F).

 

Versions

  • ASTM D4032: orifice Ø 38.1 mm, plunger Ø 25.4 mm

  • Reduced size: orifice Ø 19 mm (0.75 in), plunger Ø 12.7 mm (0.5 in), similar to ASTM D4032, for smaller samples (also listed as UGC-PF-190)

 

Typical applications

  • Woven and knitted fabrics

  • Nonwoven fabrics

  • Coated fabrics

  • Textile hand evaluation

 

Machine fit

Circular bend forces are low, so a Mark-10 F-series motorized tester (100 to 1,500 lbF) or a Galdabini 2.5 kN benchtop UTM is a good fit. Fabric tensile and tear setups are on our textiles page.

Tell us whether you need the standard or reduced orifice and your machine coupling, and we will configure the fixture: request a quote.

Product video

At a glance

  • Max. load: 20 kN

  • Test type: Circular bend stiffness

  • Orifice: Ø 38.1 mm

  • Platform height: 80 mm

  • Plunger: Ø 25.4 mm, flat

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

Fabric Stiffness Puncture Fixture Specifications

MAX. LOAD

20 kN

 

TEST TYPE

Circular bend stiffness

 

ORIFICE

Ø 38.1 mm

 

PLATFORM HEIGHT

80 mm

 

PLUNGER

Ø 25.4 mm, flat

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

 

MATERIAL

Steel, nickel-plated

 

TEMPERATURE RANGE

0 to +70 °C (others on request)

 

WEIGHT

2.2 kg

 

DRAWINGS

Dimensional drawings on data sheet; certified drawings and 3D models on request

 

PART REF.

UGC-PF-120

 

Models & Options

  • ASTM D4032 version — Orifice Ø 38.1 mm, plunger Ø 25.4 mm (Specify at order)

  • Reduced size — Orifice Ø 19 mm, plunger Ø 12.7 mm (similar to ASTM D4032) (Specify at order)

  • Machine coupling — Female clevis Ø 15.9 mm standard; others (On request)

What's Included

  • 1 circular bend fixture: platform with orifice

  • Flat-ended plunger with clevis coupling

Supported Test Standards

  • ASTM D4032 — Stiffness of fabric by the circular bend procedure

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-PF-190 Fabric Stiffness Puncture Fixture Similar Method

UGC-PF-190 Fabric Stiffness Puncture Fixture Similar Method

Open-frame circular bend fixture for comparative fabric stiffness checks by a method similar to ASTM D4032, with orifice

UGC-PF-110 Tissue Paper Ball Burst Fixture ISO 12625-9

UGC-PF-110 Tissue Paper Ball Burst Fixture ISO 12625-9

Stainless steel ball burst fixture with water tray for dry and wet tissue, pneumatic (500 N) or manual (10 kN) clamping,

UGC-PF-130 Punch Fixture 10 kN

UGC-PF-130 Punch Fixture 10 kN

Round-nosed punch-and-die fixture with three punch radii and three die holes for puncture and dome tests on sheets, film

UGC-PF-100 Pneumatic Barrier Film Penetration Fixture

UGC-PF-100 Pneumatic Barrier Film Penetration Fixture

Pneumatically clamped fixture for ASTM F1306 slow rate penetration of barrier films, with 5 kN clamping at 7 bar for sli

Fabric Stiffness Puncture Fixture FAQ

What is the circular bend procedure?

A flat fabric is pushed through a round orifice by a plunger, so it bends in all directions at once; the peak force indicates stiffness. Our ASTM D4032 guide covers the full method.

 

What are the orifice and plunger sizes?

The orifice is Ø 38.1 mm (1.5 in) on an 80 mm high platform, and the flat plunger is Ø 25.4 mm (1 in).

 

Is there a smaller version?

Yes, a reduced-size version with a Ø 19 mm orifice and Ø 12.7 mm plunger, similar to ASTM D4032, for smaller samples.

 

Why is it rated 20 kN when the test forces are low?

The robust build means the fixture is never the limiting factor; your machine's load cell sets the useful range.

 

Which tester should I use?

A Mark-10 F-series motorized tester or a Galdabini 2.5 kN benchtop UTM suits the low forces of circular bend testing.

 

Need help configuring a puncture fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.