Home › Products › Puncture Fixtures › Fabric Stiffness Puncture Fixture





Fabric Stiffness Puncture Fixture – ASTM D4032 Circular Bend
Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at once, for ASTM D4032.
Brand: Universal Grip | Model: UGC-PF-120 | ● Configured to order
Ø 38.1 mm (1.5 in) orifice on an 80 mm (3.15 in) high platform
Flat-ended plunger, Ø 25.4 mm (1 in)
One peak force reflects bending resistance in all directions
Compact 2.2 kg (4.9 lb) fixture with clevis coupling
Nickel-plated steel, rated 20 kN (4,496 lbf)
Reduced-size variant with Ø 19 mm orifice for small samples
Standards: ASTM D4032
Trusted by Global Companies


























Circular bend stiffness fixture for fabrics
The UGC-PF-120 measures the stiffness of fabrics by the circular bend procedure of ASTM D4032. Instead of bending a strip in one direction, the test pushes a flat fabric specimen through a round orifice, so it folds in all directions at once. The resulting peak force is used to assess hand and drape. Textile mills, nonwoven producers, coated fabric makers and apparel developers use it to compare finishes, check that a softening treatment has worked, or hold a fabric to a stiffness specification. See our complete ASTM D4032 guide for specimen preparation, procedure and calculations.
How it works
The fabric is laid flat over a platform with a Ø 38.1 mm (1.5 in) orifice. A flat-ended plunger of Ø 25.4 mm (1 in), driven by the crosshead, pushes the specimen down through the orifice, folding it into the opening. The platform stands 80 mm (3.15 in) high, which leaves room below for the folded fabric to pass through. The maximum force during the stroke reflects the combined bending resistance of the fabric in every direction, so a single number captures stiffness that would otherwise need separate warp and weft cantilever tests.
Construction
The fixture is nickel-plated steel for corrosion resistance and weighs 2.2 kg (4.9 lb). It is rated 20 kN (4,496 lbf), far above the forces a circular bend test produces, so the fixture itself is never the limit. It connects with a female clevis and Ø 15.9 mm (5/8 in) pin; other couplings are on request or through adapters. The standard temperature range is 0 to +70 °C (32 to 158 °F).
Versions
ASTM D4032: orifice Ø 38.1 mm, plunger Ø 25.4 mm
Reduced size: orifice Ø 19 mm (0.75 in), plunger Ø 12.7 mm (0.5 in), similar to ASTM D4032, for smaller samples (also listed as UGC-PF-190)
Typical applications
Woven and knitted fabrics
Nonwoven fabrics
Coated fabrics
Textile hand evaluation
Machine fit
Circular bend forces are low, so a Mark-10 F-series motorized tester (100 to 1,500 lbF) or a Galdabini 2.5 kN benchtop UTM is a good fit. Fabric tensile and tear setups are on our textiles page.
Tell us whether you need the standard or reduced orifice and your machine coupling, and we will configure the fixture: request a quote.
Fabric Stiffness Puncture Fixture Specifications
MAX. LOAD
20 kN
TEST TYPE
Circular bend stiffness
ORIFICE
Ø 38.1 mm
PLATFORM HEIGHT
80 mm
PLUNGER
Ø 25.4 mm, flat
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin; others on request
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
0 to +70 °C (others on request)
WEIGHT
2.2 kg
DRAWINGS
Dimensional drawings on data sheet; certified drawings and 3D models on request
PART REF.
UGC-PF-120
Models & Options
ASTM D4032 version — Orifice Ø 38.1 mm, plunger Ø 25.4 mm (Specify at order)
Reduced size — Orifice Ø 19 mm, plunger Ø 12.7 mm (similar to ASTM D4032) (Specify at order)
Machine coupling — Female clevis Ø 15.9 mm standard; others (On request)
What's Included
1 circular bend fixture: platform with orifice
Flat-ended plunger with clevis coupling
Supported Test Standards
ASTM D4032 — Stiffness of fabric by the circular bend procedure
Compatible Grips & Fixtures
UGC-PF-190 Fabric Stiffness Puncture Fixture, Similar Method — Reduced-size circular bend variant
Motorized Tensile Testers — Mark-10 F-series frames for low-force bend tests
2.5 kN Benchtop UTM — Galdabini frame for fabric testing
Textiles Testing — Fabric tensile, tear and burst setups
Adapters — Couplings for other machine connections
“Customer quote”
Related Equipment
UGC-PF-190 Fabric Stiffness Puncture Fixture Similar Method
Open-frame circular bend fixture for comparative fabric stiffness checks by a method similar to ASTM D4032, with orifice
UGC-PF-110 Tissue Paper Ball Burst Fixture ISO 12625-9
Stainless steel ball burst fixture with water tray for dry and wet tissue, pneumatic (500 N) or manual (10 kN) clamping,
UGC-PF-130 Punch Fixture 10 kN
Round-nosed punch-and-die fixture with three punch radii and three die holes for puncture and dome tests on sheets, film
UGC-PF-100 Pneumatic Barrier Film Penetration Fixture
Pneumatically clamped fixture for ASTM F1306 slow rate penetration of barrier films, with 5 kN clamping at 7 bar for sli
Fabric Stiffness Puncture Fixture FAQ
What is the circular bend procedure?
A flat fabric is pushed through a round orifice by a plunger, so it bends in all directions at once; the peak force indicates stiffness. Our ASTM D4032 guide covers the full method.
What are the orifice and plunger sizes?
The orifice is Ø 38.1 mm (1.5 in) on an 80 mm high platform, and the flat plunger is Ø 25.4 mm (1 in).
Is there a smaller version?
Yes, a reduced-size version with a Ø 19 mm orifice and Ø 12.7 mm plunger, similar to ASTM D4032, for smaller samples.
Why is it rated 20 kN when the test forces are low?
The robust build means the fixture is never the limiting factor; your machine's load cell sets the useful range.
Which tester should I use?
A Mark-10 F-series motorized tester or a Galdabini 2.5 kN benchtop UTM suits the low forces of circular bend testing.