top of page

Home  ›  Products  ›  Puncture Fixtures  ›  Fabric Stiffness Puncture Fixture Similar Method

UGC-PF-190 open-frame fabric stiffness circular bend fixture on four columns by Universal Grip
UGC-PF-190 open-frame fabric stiffness circular bend fixture on four columns by Universal Grip
UGC-PF-190 Fabric Stiffness Puncture Fixture Similar Method by Universal Grip, view 2
UGC-PF-190 Fabric Stiffness Puncture Fixture Similar Method by Universal Grip, view 3
UGC-PF-190 Fabric Stiffness Puncture Fixture Similar Method by Universal Grip, view 4

Fabric Stiffness Puncture Fixture Similar Method – Open Frame

Open-frame circular bend fixture for comparative fabric stiffness checks by a method similar to ASTM D4032, with orifice and plunger sized to order.

Brand: Universal Grip  |  Model: UGC-PF-190  |  ● Configured to order

  • Circular bend stiffness method similar to ASTM D4032

  • Platform plate with circular orifice on four columns

  • Open frame lets the fabric pass through the orifice freely

  • Flat-ended cylindrical plunger on the upper adapter

  • Ø 19 mm orifice and Ø 12.7 mm plunger version available

  • Light aluminum and steel build with pin couplings on plunger and base

Standards: ASTM D4032

Trusted by Global Companies

Circular bend fixture for comparative fabric stiffness

The UGC-PF-190 gives textile labs a quick, repeatable stiffness number for fabrics using a circular bend method similar to ASTM D4032. It is aimed at comparative work: ranking fabrics, checking a finish change or screening production lots, where the full standard geometry is not required. If you need the exact ASTM D4032 dimensions, use the full-size fixture described below.

 

How it works

A fabric specimen is laid over a platform plate with a circular orifice. The plate stands on four columns, which leaves the space below open so the fabric can pass through the hole without catching. A flat-ended cylindrical plunger on the upper adapter pushes the fabric down through the orifice. Because the fabric has to fold in every direction at once, the peak force reflects its overall bending stiffness rather than stiffness along one yarn direction. Higher peak force means a stiffer fabric.

 

Orifice and plunger sizes

Orifice and plunger diameters are made to order. A version with a Ø 19 mm (0.75 in) orifice and Ø 12.7 mm (0.50 in) plunger is available for smaller specimens and lighter fabrics. Pin couplings connect the plunger and the base to the machine, and other sizes are handled with adapters.

 

Choosing between this fixture and UGC-PF-120

The UGC-PF-120 is built to the full ASTM D4032 geometry: Ø 38.1 mm orifice, Ø 25.4 mm plunger, 80 mm platform. Choose the UGC-PF-120 when results must be reported to the standard. Choose the UGC-PF-190 when you want a lighter, open-frame fixture for comparative checks or a reduced-size geometry. See our ASTM D4032 guide for the background on the circular bend procedure, specimen preparation and how results are reported.

 

Typical applications

  • Woven and knitted fabrics

  • Nonwoven fabrics

  • Technical textiles

  • Comparative stiffness checks

 

Machine fit

Maximum load is confirmed on request. Circular bend forces on apparel and nonwoven fabrics are usually modest, so a Mark-10 motorized tester from our tensile testers range or a Galdabini 2.5 kN benchtop UTM is the usual platform. Adapters match the pin couplings to your frame. More fixtures for textiles are on our textiles page.

Tell us the orifice and plunger diameters, fabric type and machine coupling, and we will quote the fixture.

Product video

At a glance

  • Test type: Circular bend stiffness

  • Method: Similar to ASTM D4032

  • Platform: Plate with circular orifice on four columns

  • Orifice: On request (Ø 19 mm version available)

  • Plunger: Flat-ended (Ø 12.7 mm version available)

  • Max. load: On request

Fabric Stiffness Puncture Fixture Similar Method Specifications

TEST TYPE

Circular bend stiffness

 

METHOD

Similar to ASTM D4032

 

PLATFORM

Plate with circular orifice on four columns

 

ORIFICE

On request (Ø 19 mm version available)

 

PLUNGER

Flat-ended (Ø 12.7 mm version available)

 

MAX. LOAD

On request

 

COUPLING

Clevis pin coupling; other sizes via adapters

 

MATERIAL

Aluminum / steel

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-PF-190

 

Models & Options

  • Ø 19 mm orifice / Ø 12.7 mm plunger — Reduced-size geometry for smaller specimens (Specify at order)

  • Other orifice and plunger sizes — Made to your comparative method (On request)

  • Coupling adapters — Match the pin couplings to your machine (On request)

What's Included

  • Platform plate with circular orifice on four columns

  • Flat-ended cylindrical plunger on the upper adapter

  • Pin couplings on plunger and base

  • Orifice and plunger diameters as specified at order

Supported Test Standards

  • ASTM D4032 — Fabric stiffness by the circular bend procedure (similar method)

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-PF-120 Fabric Stiffness Puncture Fixture

UGC-PF-120 Fabric Stiffness Puncture Fixture

Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at

UGC-PF-180 Foot and Leg Protector Puncture Fixture ISO 20344

UGC-PF-180 Foot and Leg Protector Puncture Fixture ISO 20344

Nail puncture fixture for safety footwear soles and penetration-resistant inserts, with Ø 3 mm and Ø 4.5 mm test nails f

UGC-PF-200 Shade Net Ball Burst Fixture

UGC-PF-200 Shade Net Ball Burst Fixture

Ball burst fixture for HDPE woven shade nets: a Ø 50 mm plastic ball pushes through net clamped over a Ø 102 mm opening

UGC-PF-170 Food Packaging Foil Puncture Fixture JIS Z1707

UGC-PF-170 Food Packaging Foil Puncture Fixture JIS Z1707

Stainless steel needle puncture fixture for food packaging films to JIS Z 1707: a Ø 1 mm needle pierces film clamped ove

Fabric Stiffness Puncture Fixture Similar Method FAQ

Is the UGC-PF-190 an ASTM D4032 fixture?

It uses a circular bend method similar to ASTM D4032 for comparative checks. For the full standard geometry choose the UGC-PF-120.

 

Where can I read about the circular bend procedure?

Our ASTM D4032 guide covers specimen preparation, procedure and reporting.

 

What orifice and plunger sizes are available?

Sizes are made to order; a Ø 19 mm orifice with Ø 12.7 mm plunger version is available.

 

What does the peak force tell me?

The fabric's overall bending stiffness, since it must fold in all directions to pass through the orifice.

 

What is it made of?

Aluminum and steel, with a platform plate on four columns.

 

How does it connect to my machine?

Pin couplings on plunger and base; other sizes via adapters.

 

Need help configuring a puncture fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page