Home › Products › Puncture Fixtures › Fabric Stiffness Puncture Fixture Similar Method





Fabric Stiffness Puncture Fixture Similar Method – Open Frame
Open-frame circular bend fixture for comparative fabric stiffness checks by a method similar to ASTM D4032, with orifice and plunger sized to order.
Brand: Universal Grip | Model: UGC-PF-190 | ● Configured to order
Circular bend stiffness method similar to ASTM D4032
Platform plate with circular orifice on four columns
Open frame lets the fabric pass through the orifice freely
Flat-ended cylindrical plunger on the upper adapter
Ø 19 mm orifice and Ø 12.7 mm plunger version available
Light aluminum and steel build with pin couplings on plunger and base
Standards: ASTM D4032
Trusted by Global Companies


























Circular bend fixture for comparative fabric stiffness
The UGC-PF-190 gives textile labs a quick, repeatable stiffness number for fabrics using a circular bend method similar to ASTM D4032. It is aimed at comparative work: ranking fabrics, checking a finish change or screening production lots, where the full standard geometry is not required. If you need the exact ASTM D4032 dimensions, use the full-size fixture described below.
How it works
A fabric specimen is laid over a platform plate with a circular orifice. The plate stands on four columns, which leaves the space below open so the fabric can pass through the hole without catching. A flat-ended cylindrical plunger on the upper adapter pushes the fabric down through the orifice. Because the fabric has to fold in every direction at once, the peak force reflects its overall bending stiffness rather than stiffness along one yarn direction. Higher peak force means a stiffer fabric.
Orifice and plunger sizes
Orifice and plunger diameters are made to order. A version with a Ø 19 mm (0.75 in) orifice and Ø 12.7 mm (0.50 in) plunger is available for smaller specimens and lighter fabrics. Pin couplings connect the plunger and the base to the machine, and other sizes are handled with adapters.
Choosing between this fixture and UGC-PF-120
The UGC-PF-120 is built to the full ASTM D4032 geometry: Ø 38.1 mm orifice, Ø 25.4 mm plunger, 80 mm platform. Choose the UGC-PF-120 when results must be reported to the standard. Choose the UGC-PF-190 when you want a lighter, open-frame fixture for comparative checks or a reduced-size geometry. See our ASTM D4032 guide for the background on the circular bend procedure, specimen preparation and how results are reported.
Typical applications
Woven and knitted fabrics
Nonwoven fabrics
Technical textiles
Comparative stiffness checks
Machine fit
Maximum load is confirmed on request. Circular bend forces on apparel and nonwoven fabrics are usually modest, so a Mark-10 motorized tester from our tensile testers range or a Galdabini 2.5 kN benchtop UTM is the usual platform. Adapters match the pin couplings to your frame. More fixtures for textiles are on our textiles page.
Tell us the orifice and plunger diameters, fabric type and machine coupling, and we will quote the fixture.
Fabric Stiffness Puncture Fixture Similar Method Specifications
TEST TYPE
Circular bend stiffness
METHOD
Similar to ASTM D4032
PLATFORM
Plate with circular orifice on four columns
ORIFICE
On request (Ø 19 mm version available)
PLUNGER
Flat-ended (Ø 12.7 mm version available)
MAX. LOAD
On request
COUPLING
Clevis pin coupling; other sizes via adapters
MATERIAL
Aluminum / steel
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-PF-190
Models & Options
Ø 19 mm orifice / Ø 12.7 mm plunger — Reduced-size geometry for smaller specimens (Specify at order)
Other orifice and plunger sizes — Made to your comparative method (On request)
Coupling adapters — Match the pin couplings to your machine (On request)
What's Included
Platform plate with circular orifice on four columns
Flat-ended cylindrical plunger on the upper adapter
Pin couplings on plunger and base
Orifice and plunger diameters as specified at order
Supported Test Standards
ASTM D4032 — Fabric stiffness by the circular bend procedure (similar method)
Compatible Grips & Fixtures
UGC-PF-120 Fabric Stiffness Fixture — Full ASTM D4032 geometry
ASTM D4032 Guide — Circular bend procedure explained
2.5 kN Benchtop UTM — Galdabini frame for textile tests
Tensile Testers — Mark-10 motorized testers for low-force work
Textiles Testing — Grips and fixtures for fabrics
“Customer quote”
Related Equipment
UGC-PF-120 Fabric Stiffness Puncture Fixture
Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at
UGC-PF-180 Foot and Leg Protector Puncture Fixture ISO 20344
Nail puncture fixture for safety footwear soles and penetration-resistant inserts, with Ø 3 mm and Ø 4.5 mm test nails f
UGC-PF-200 Shade Net Ball Burst Fixture
Ball burst fixture for HDPE woven shade nets: a Ø 50 mm plastic ball pushes through net clamped over a Ø 102 mm opening
UGC-PF-170 Food Packaging Foil Puncture Fixture JIS Z1707
Stainless steel needle puncture fixture for food packaging films to JIS Z 1707: a Ø 1 mm needle pierces film clamped ove
Fabric Stiffness Puncture Fixture Similar Method FAQ
Is the UGC-PF-190 an ASTM D4032 fixture?
It uses a circular bend method similar to ASTM D4032 for comparative checks. For the full standard geometry choose the UGC-PF-120.
Where can I read about the circular bend procedure?
Our ASTM D4032 guide covers specimen preparation, procedure and reporting.
What orifice and plunger sizes are available?
Sizes are made to order; a Ø 19 mm orifice with Ø 12.7 mm plunger version is available.
What does the peak force tell me?
The fabric's overall bending stiffness, since it must fold in all directions to pass through the orifice.
What is it made of?
Aluminum and steel, with a platform plate on four columns.
How does it connect to my machine?
Pin couplings on plunger and base; other sizes via adapters.