top of page

Home  ›  Products  ›  Puncture Fixtures  ›  Huber Needle Coring Fixture

UGC-PF-160 Huber needle coring fixture with polycarbonate collection chamber by Universal Grip
UGC-PF-160 Huber needle coring fixture with polycarbonate collection chamber by Universal Grip
UGC-PF-160 Huber Needle Coring Fixture by Universal Grip, view 2
Product photo 3
Product photo 4

Huber Needle Coring Fixture – ASTM F3212

Coring test fixture for non-coring Huber needles: the needle passes through a port septum and any cored fragments collect in a clear chamber for inspection.

Brand: Universal Grip  |  Model: UGC-PF-160  |  ● Configured to order

  • Used for coring tests on Huber needles to ASTM F3212

  • Transparent polycarbonate chamber collects cored fragments

  • Stainless steel 304 top plate holds the septum

  • Controlled insertion speed and force record in a testing machine

  • 1 kN (about 225 lbf) capacity for needle penetration forces

  • Female clevis coupling for a Ø 15.9 mm (5/8 in) pin

Standards: ASTM F3212

Trusted by Global Companies

Coring test fixture for Huber needles and port septa

The UGC-PF-160 is a test fixture for medical device labs that validate non-coring (Huber) needles and the septa of implanted ports. It is used for coring tests such as ASTM F3212, where the question is not only how much force the needle needs but whether it cuts fragments out of the septum on the way through. Capacity is 1 kN (about 225 lbf).

 

How it works

The septum is held in a stainless steel top plate. The needle, mounted on the testing machine crosshead, is driven through it at a set speed while force is recorded. Below the plate sits a transparent polycarbonate chamber, so any material cored from the septum falls into a clear, closed space where it can be seen and collected for counting or inspection. Running the insertion in a testing machine instead of by hand gives repeatable speed and alignment from one needle to the next, which is what makes results comparable across lots. The force curve and the fragment check for each needle can then be recorded together, so every needle in a validation run has its own traceable result.

 

Construction

  • Top plate in stainless steel 1.4301 (304)

  • Transparent polycarbonate collection chamber

  • Female clevis for a Ø 15.9 mm (5/8 in) pin on the lower fixture

Septum size and needle gauge are specified at order so the top plate fits your port design. Stainless steel and polycarbonate are easy to clean between test series, which keeps stray particles from an earlier needle out of the next fragment count.

 

Typical applications

  • Implanted port septa

  • Non-coring needles

  • Medical device validation

  • Infusion systems

For hypodermic needle puncture of protective clothing, gloves or closures, see the UGC-PF-140 needle puncture fixture; both sit in our puncture fixtures range.

 

Machine fit

Needle penetration forces are low, and the 1 kN rating fits a Mark-10 motorized tester such as the 300 lb tensile tester. Labs that need tighter speed control and full data records for validation files often choose a Galdabini 2.5 kN benchtop UTM with our test software. Adapters are available if your machine does not take a 5/8 in clevis.

Tell us your septum size, needle gauge and machine coupling and we will quote the fixture.

Product video

At a glance

  • Max. load: 1 kN

  • Test type: Needle coring / penetration

  • Specimen: Huber needles, septa

  • Septum holder: Stainless steel top plate

  • Chamber: Transparent polycarbonate cylinder

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin

Huber Needle Coring Fixture Specifications

MAX. LOAD

1 kN

 

TEST TYPE

Needle coring / penetration

 

SPECIMEN

Huber needles, septa

 

SEPTUM HOLDER

Stainless steel top plate

 

CHAMBER

Transparent polycarbonate cylinder

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin

 

MATERIAL

Stainless steel 1.4301 (304), polycarbonate

 

TEMPERATURE RANGE

On request

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-PF-160

 

Models & Options

  • Septum top plate — Made to your septum size (Specify at order)

  • Needle gauge — Set up for the Huber needle gauge you test (Specify at order)

  • Coupling adapters — For machines without a 5/8 in clevis (On request)

What's Included

  • Stainless steel 304 top plate to hold the septum

  • Transparent polycarbonate collection chamber

  • Female clevis coupling for a Ø 15.9 mm (5/8 in) pin

  • Needle mounting and septum fit confirmed at quote to your needle gauge and septum size

Supported Test Standards

  • ASTM F3212 — Coring testing of Huber needles

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-PF-140 Protective Clothing Needle Puncture Fixture

UGC-PF-140 Protective Clothing Needle Puncture Fixture

2 kN needle puncture fixture for protective clothing, gloves and medical needle tests, with a clamped specimen holder an

UGC-PF-150 XY Adjustable Puncture Fixture

UGC-PF-150 XY Adjustable Puncture Fixture

Puncture fixture on a manual XY cross table, so you can place several test points on one clamped specimen without taking

UGC-PF-170 Food Packaging Foil Puncture Fixture JIS Z1707

UGC-PF-170 Food Packaging Foil Puncture Fixture JIS Z1707

Stainless steel needle puncture fixture for food packaging films to JIS Z 1707: a Ø 1 mm needle pierces film clamped ove

UGC-PF-180 Foot and Leg Protector Puncture Fixture ISO 20344

UGC-PF-180 Foot and Leg Protector Puncture Fixture ISO 20344

Nail puncture fixture for safety footwear soles and penetration-resistant inserts, with Ø 3 mm and Ø 4.5 mm test nails f

Huber Needle Coring Fixture FAQ

What test is the UGC-PF-160 used for?

Coring tests on non-coring (Huber) needles, such as ASTM F3212, where a needle is driven through a port septum and cored fragments are checked.

 

How are cored fragments collected?

They fall into a transparent polycarbonate chamber below the septum plate, where they can be seen and collected.

 

What is the load capacity?

1 kN, about 225 lbf.

 

What materials is it made of?

Stainless steel 1.4301 (304) and polycarbonate.

 

Which tester should I use?

A Mark-10 300 lb tensile tester covers the rating; a Galdabini 2.5 kN benchtop UTM suits validation work that needs full data records.

 

What do I need to specify?

Septum size, needle gauge and your machine coupling.

 

Need help configuring a puncture fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page