top of page

Home  ›  Products  ›  Puncture Fixtures  ›  Protective Clothing Needle Puncture Fixture

UGC-PF-140 protective clothing needle puncture fixture with clamped specimen holder by Universal Grip
UGC-PF-140 protective clothing needle puncture fixture with clamped specimen holder by Universal Grip
UGC-PF-140 Protective Clothing Needle Puncture Fixture by Universal Grip, view 2
UGC-PF-140 Protective Clothing Needle Puncture Fixture by Universal Grip, view 3
UGC-PF-140 Protective Clothing Needle Puncture Fixture by Universal Grip, view 4

Protective Clothing Needle Puncture Fixture – 2 kN

2 kN needle puncture fixture for protective clothing, gloves and medical needle tests, with a clamped specimen holder and interchangeable needle holder.

Brand: Universal Grip  |  Model: UGC-PF-140  |  ● Configured to order

  • 2 kN (about 450 lbf) capacity for low-force needle puncture tests

  • Used for tests such as ASTM F2878, ASTM F1342 and ISO 7864

  • Clamped specimen holder keeps flat materials taut under the needle

  • Interchangeable needle holder in the upper adapter

  • Alternative needle holder design available for ASTM F2878

  • Light steel, aluminum and plastic build; 5/8 in clevis coupling

Standards: ASTM F2878  ·  ASTM F1342  ·  ISO 7864  ·  ISO 11040-4

Trusted by Global Companies

Needle puncture fixture for protective clothing and medical needles

The UGC-PF-140 measures how much force it takes for a needle to pierce a material. Safety and PPE labs use it to rate glove and protective clothing fabrics against hypodermic needle sticks, and medical device labs use the same hardware for needle penetration tests on closures and related items. Capacity is 2 kN (about 450 lbf), sized for the low forces involved.

 

How it works

The specimen is clamped flat in the lower holder so it cannot slip or wrinkle as the needle loads it. A needle held in the upper adapter is driven down at a controlled speed, and the testing machine records force against travel until the needle breaks through. The peak force, and the shape of the curve leading up to it, are what you report. Because the needle sits in an interchangeable holder, you can change needle type and gauge between test series without disturbing the specimen holder.

 

Needle holder versions

  • Standard – multi-standard needle holder for protective clothing and medical needle work.

  • ASTM F2878 – alternative needle holder design for hypodermic needle puncture testing of protective clothing materials.

Tell us the needle type and gauge your method specifies when you order so the holder is set up for it.

 

Standards and typical applications

The fixture is used for tests such as ASTM F2878 and ASTM F1342 on protective clothing materials, and for needle penetration work under medical standards including ISO 7864, ISO 80369-7, ISO 11040-4, ISO 8536-4 and DIN 13097-4. GOST 25377 and GOST 22967 are also covered by the same layout. Typical specimens include:

  • Protective gloves and clothing

  • Medical needles and syringes

  • Infusion bottle closures

  • Healthcare PPE

 

Machine fit and coupling

At 2 kN the fixture fits low-force frames well. A Mark-10 motorized tester such as the 500 lb tensile tester covers the full rating, and a Galdabini 2.5 kN benchtop UTM adds higher-resolution control for medical device work. The fixture uses a female clevis for a Ø 15.9 mm (5/8 in) pin, and adapters are available for other couplings. Browse our full range of puncture fixtures for probe, ball and nail geometries.

Send us the standard, needle type and gauge, specimen size and machine coupling, and we will configure and quote the fixture.

Product video

At a glance

  • Max. load: 2 kN

  • Test type: Needle puncture / penetration

  • Specimen: Protective clothing materials, closures, medical items

  • Specimen holding: Clamped holder for flat materials

  • Needle: Interchangeable holder for test needles in the upper adapter

  • Needle holder versions: Standard (multi-standard); alternative design for ASTM F2878

Protective Clothing Needle Puncture Fixture Specifications

MAX. LOAD

2 kN

 

TEST TYPE

Needle puncture / penetration

 

SPECIMEN

Protective clothing materials, closures, medical items

 

SPECIMEN HOLDING

Clamped holder for flat materials

 

NEEDLE

Interchangeable holder for test needles in the upper adapter

 

NEEDLE HOLDER VERSIONS

Standard (multi-standard); alternative design for ASTM F2878

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin

 

MATERIAL

Steel, aluminum, plastic

 

TEMPERATURE RANGE

On request

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-PF-140

 

Models & Options

  • Standard needle holder — Multi-standard holder for protective clothing and medical needle tests (Specify at order)

  • ASTM F2878 needle holder — Alternative needle holder design for ASTM F2878 (Specify at order)

  • Needle type and gauge — Set up to the needle your method specifies (Specify at order)

  • Coupling adapters — For machines without a 5/8 in clevis (On request)

What's Included

  • Clamped specimen holder for flat materials

  • Upper adapter with needle holder (standard or ASTM F2878 design)

  • Female clevis coupling for a Ø 15.9 mm (5/8 in) pin

  • Test needles: specify type and gauge at order; supply confirmed with your quote

Supported Test Standards

  • ASTM F2878 — Protective clothing material resistance to hypodermic needle puncture

  • ASTM F1342 — Protective clothing material resistance to puncture

  • ISO 7864 — Sterile hypodermic needles for single use

  • ISO 11040-4 — Prefillable syringes: glass barrels for injectables

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-PF-130 Punch Fixture 10 kN

UGC-PF-130 Punch Fixture 10 kN

Round-nosed punch-and-die fixture with three punch radii and three die holes for puncture and dome tests on sheets, film

UGC-PF-150 XY Adjustable Puncture Fixture

UGC-PF-150 XY Adjustable Puncture Fixture

Puncture fixture on a manual XY cross table, so you can place several test points on one clamped specimen without taking

UGC-PF-120 Fabric Stiffness Puncture Fixture

UGC-PF-120 Fabric Stiffness Puncture Fixture

Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at

UGC-PF-160 Huber Needle Coring Fixture

UGC-PF-160 Huber Needle Coring Fixture

Coring test fixture for non-coring Huber needles: the needle passes through a port septum and any cored fragments collec

Protective Clothing Needle Puncture Fixture FAQ

Which standards is the UGC-PF-140 used for?

Protective clothing tests such as ASTM F2878 and ASTM F1342, and needle penetration tests under medical standards including ISO 7864, ISO 80369-7, ISO 11040-4, ISO 8536-4 and DIN 13097-4.

 

What is the load capacity?

2 kN, about 450 lbf.

 

Is there a dedicated version for ASTM F2878?

Yes. An alternative needle holder design is available for ASTM F2878 testing.

 

Are needles included?

The fixture holds test needles in an interchangeable holder. Specify needle type and gauge when ordering and we confirm needle supply with the quote.

 

Which tester do I need?

A Mark-10 motorized tester such as the 500 lb tensile tester or a Galdabini 2.5 kN benchtop UTM covers the rating.

 

What coupling does it use?

A female clevis for a Ø 15.9 mm (5/8 in) pin; adapters are available for other couplings.

 

Need help configuring a puncture fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page