Home › Products › Puncture Fixtures › Protective Clothing Needle Puncture Fixture





Protective Clothing Needle Puncture Fixture – 2 kN
2 kN needle puncture fixture for protective clothing, gloves and medical needle tests, with a clamped specimen holder and interchangeable needle holder.
Brand: Universal Grip | Model: UGC-PF-140 | ● Configured to order
2 kN (about 450 lbf) capacity for low-force needle puncture tests
Used for tests such as ASTM F2878, ASTM F1342 and ISO 7864
Clamped specimen holder keeps flat materials taut under the needle
Interchangeable needle holder in the upper adapter
Alternative needle holder design available for ASTM F2878
Light steel, aluminum and plastic build; 5/8 in clevis coupling
Standards: ASTM F2878 · ASTM F1342 · ISO 7864 · ISO 11040-4
Trusted by Global Companies


























Needle puncture fixture for protective clothing and medical needles
The UGC-PF-140 measures how much force it takes for a needle to pierce a material. Safety and PPE labs use it to rate glove and protective clothing fabrics against hypodermic needle sticks, and medical device labs use the same hardware for needle penetration tests on closures and related items. Capacity is 2 kN (about 450 lbf), sized for the low forces involved.
How it works
The specimen is clamped flat in the lower holder so it cannot slip or wrinkle as the needle loads it. A needle held in the upper adapter is driven down at a controlled speed, and the testing machine records force against travel until the needle breaks through. The peak force, and the shape of the curve leading up to it, are what you report. Because the needle sits in an interchangeable holder, you can change needle type and gauge between test series without disturbing the specimen holder.
Needle holder versions
Standard – multi-standard needle holder for protective clothing and medical needle work.
ASTM F2878 – alternative needle holder design for hypodermic needle puncture testing of protective clothing materials.
Tell us the needle type and gauge your method specifies when you order so the holder is set up for it.
Standards and typical applications
The fixture is used for tests such as ASTM F2878 and ASTM F1342 on protective clothing materials, and for needle penetration work under medical standards including ISO 7864, ISO 80369-7, ISO 11040-4, ISO 8536-4 and DIN 13097-4. GOST 25377 and GOST 22967 are also covered by the same layout. Typical specimens include:
Protective gloves and clothing
Medical needles and syringes
Infusion bottle closures
Healthcare PPE
Machine fit and coupling
At 2 kN the fixture fits low-force frames well. A Mark-10 motorized tester such as the 500 lb tensile tester covers the full rating, and a Galdabini 2.5 kN benchtop UTM adds higher-resolution control for medical device work. The fixture uses a female clevis for a Ø 15.9 mm (5/8 in) pin, and adapters are available for other couplings. Browse our full range of puncture fixtures for probe, ball and nail geometries.
Send us the standard, needle type and gauge, specimen size and machine coupling, and we will configure and quote the fixture.
Product video
At a glance
Max. load: 2 kN
Test type: Needle puncture / penetration
Specimen: Protective clothing materials, closures, medical items
Specimen holding: Clamped holder for flat materials
Needle: Interchangeable holder for test needles in the upper adapter
Needle holder versions: Standard (multi-standard); alternative design for ASTM F2878
Protective Clothing Needle Puncture Fixture Specifications
MAX. LOAD
2 kN
TEST TYPE
Needle puncture / penetration
SPECIMEN
Protective clothing materials, closures, medical items
SPECIMEN HOLDING
Clamped holder for flat materials
NEEDLE
Interchangeable holder for test needles in the upper adapter
NEEDLE HOLDER VERSIONS
Standard (multi-standard); alternative design for ASTM F2878
COUPLING
Female clevis, Ø 15.9 mm (5/8 in) pin
MATERIAL
Steel, aluminum, plastic
TEMPERATURE RANGE
On request
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-PF-140
Models & Options
Standard needle holder — Multi-standard holder for protective clothing and medical needle tests (Specify at order)
ASTM F2878 needle holder — Alternative needle holder design for ASTM F2878 (Specify at order)
Needle type and gauge — Set up to the needle your method specifies (Specify at order)
Coupling adapters — For machines without a 5/8 in clevis (On request)
What's Included
Clamped specimen holder for flat materials
Upper adapter with needle holder (standard or ASTM F2878 design)
Female clevis coupling for a Ø 15.9 mm (5/8 in) pin
Test needles: specify type and gauge at order; supply confirmed with your quote
Supported Test Standards
ASTM F2878 — Protective clothing material resistance to hypodermic needle puncture
ASTM F1342 — Protective clothing material resistance to puncture
ISO 7864 — Sterile hypodermic needles for single use
ISO 11040-4 — Prefillable syringes: glass barrels for injectables
Compatible Grips & Fixtures
500 lb Tensile Tester — Mark-10 motorized tester covering the 2 kN rating
2.5 kN Benchtop UTM — Galdabini frame for medical device puncture work
ISO 11040-4 Guide — Prefillable syringe glass barrel tests
Adapters — Couplings for other machine connections
Textiles Testing — Grips and fixtures for fabric and PPE materials
“Customer quote”
Related Equipment
UGC-PF-130 Punch Fixture 10 kN
Round-nosed punch-and-die fixture with three punch radii and three die holes for puncture and dome tests on sheets, film
UGC-PF-150 XY Adjustable Puncture Fixture
Puncture fixture on a manual XY cross table, so you can place several test points on one clamped specimen without taking
UGC-PF-120 Fabric Stiffness Puncture Fixture
Circular bend fixture with 38.1 mm orifice and 25.4 mm flat plunger that measures fabric stiffness in all directions at
UGC-PF-160 Huber Needle Coring Fixture
Coring test fixture for non-coring Huber needles: the needle passes through a port septum and any cored fragments collec
Protective Clothing Needle Puncture Fixture FAQ
Which standards is the UGC-PF-140 used for?
Protective clothing tests such as ASTM F2878 and ASTM F1342, and needle penetration tests under medical standards including ISO 7864, ISO 80369-7, ISO 11040-4, ISO 8536-4 and DIN 13097-4.
What is the load capacity?
2 kN, about 450 lbf.
Is there a dedicated version for ASTM F2878?
Yes. An alternative needle holder design is available for ASTM F2878 testing.
Are needles included?
The fixture holds test needles in an interchangeable holder. Specify needle type and gauge when ordering and we confirm needle supply with the quote.
Which tester do I need?
A Mark-10 motorized tester such as the 500 lb tensile tester or a Galdabini 2.5 kN benchtop UTM covers the rating.
What coupling does it use?
A female clevis for a Ø 15.9 mm (5/8 in) pin; adapters are available for other couplings.