Home › Products › Puncture Fixtures › Food Packaging Foil Puncture Fixture JIS Z1707





Food Packaging Foil Puncture Fixture JIS Z1707 – 250 N
Stainless steel needle puncture fixture for food packaging films to JIS Z 1707: a Ø 1 mm needle pierces film clamped over a Ø 20 mm opening.
Brand: Universal Grip | Model: UGC-PF-170 | ● Configured to order
Used for piercing strength tests on food packaging film to JIS Z 1707
Ø 1 mm x 20 mm needle pierces the film at constant speed
Film clamped flat over a Ø 20 mm (0.79 in) opening
Upper, lower and clamping plates hold the specimen without wrinkles
Stainless steel throughout, suited to food labs
250 N (about 56 lbf) capacity matched to film testing
Standards: JIS Z 1707
Trusted by Global Companies


























Needle puncture fixture for food packaging film to JIS Z 1707
The UGC-PF-170 measures the piercing strength of food packaging films, laminates and pouch materials. It is set up for tests such as JIS Z 1707, where a fine needle is pushed through a clamped film and the peak force at puncture is reported. Food packaging converters and brand-owner QC labs use it to compare film structures, check incoming rolls and confirm a laminate change has not weakened the pack. A pinhole from a bone fragment, a sharp edge or a stray staple is a common way for a sealed food pack to fail, and needle piercing strength is a direct, inexpensive way to rank films against that risk.
How it works
The film is sandwiched between stainless steel plates that each have a Ø 20 mm (0.79 in) hole, so a defined circle of film is left free. A Ø 1 mm (0.04 in), 20 mm long needle on the upper adapter is driven down through the centre of that circle at constant speed. The testing machine records force against travel, and the maximum force before the needle breaks through is the piercing strength of the film. The clamping plate keeps the film flat and tensioned evenly across the opening, so wrinkles do not shift the result.
Plates and needle
Lower plate 120 x 80 mm (4.72 x 3.15 in)
Upper plate 120 x 80 mm with Ø 20 mm hole
Clamping plate 55 x 80 mm with Ø 20 mm hole
Needle Ø 1 x 20 mm
All parts are stainless steel, so the fixture can be wiped down between specimens in a food lab without corrosion concerns.
Typical applications
Food packaging films
Retort pouches
Laminated films
Packaging QC
For European packaging puncture tests, compare the UGC-PF-080 fixture for EN 14477; the wider puncture fixtures range covers barrier film, stretch film and probe tests.
Machine fit
At 250 N (about 56 lbf), the fixture runs comfortably on a Mark-10 motorized tester such as the 100 lb tensile tester, which also suits the low forces of thin film. Labs that already run a Galdabini 2.5 kN benchtop UTM for film tensile work can use the same frame. The machine coupling is made on request, and adapters are available.
Tell us your machine coupling and film thickness range and we will quote the fixture.
Food Packaging Foil Puncture Fixture JIS Z1707 Specifications
MAX. LOAD
250 N
TEST TYPE
Needle puncture
SPECIMEN OPENING
Ø 20 mm
NEEDLE
Ø 1 x 20 mm
LOWER PLATE
120 x 80 mm
UPPER PLATE
120 x 80 mm, Ø 20 mm hole
CLAMPING PLATE
55 x 80 mm, Ø 20 mm hole
MATERIAL
Stainless steel
COUPLING
On request
DRAWINGS
Dimensional drawings and 3D models on request
PART REF.
UGC-PF-170
Models & Options
Machine coupling — Made to suit your tester or UTM (Specify at order)
Coupling adapters — For mounting on an existing load cell or crosshead (On request)
What's Included
Lower plate 120 x 80 mm
Upper plate 120 x 80 mm with Ø 20 mm hole
Clamping plate 55 x 80 mm with Ø 20 mm hole
Needle Ø 1 x 20 mm
Machine coupling to your specification
Supported Test Standards
JIS Z 1707 — Plastic films for food packaging, piercing strength
Compatible Grips & Fixtures
100 lb Tensile Tester — Mark-10 motorized tester sized for 250 N film puncture
2.5 kN Benchtop UTM — Galdabini frame for film puncture and tensile
UGC-PF-080 Packaging Puncture Fixture — Packaging puncture fixture for EN 14477
Plastics Testing — Grips and fixtures for plastic film
Adapters — Couplings for your machine
“Customer quote”
Related Equipment
UGC-PF-080 Packaging Puncture Resistance Fixture EN 14477
Needle puncture fixture with interchangeable 0.8 mm round or 3 mm flat needles for packaging films, pouches and laminate
UGC-PF-160 Huber Needle Coring Fixture
Coring test fixture for non-coring Huber needles: the needle passes through a port septum and any cored fragments collec
UGC-PF-180 Foot and Leg Protector Puncture Fixture ISO 20344
Nail puncture fixture for safety footwear soles and penetration-resistant inserts, with Ø 3 mm and Ø 4.5 mm test nails f
UGC-PF-150 XY Adjustable Puncture Fixture
Puncture fixture on a manual XY cross table, so you can place several test points on one clamped specimen without taking
Food Packaging Foil Puncture Fixture JIS Z1707 FAQ
What does the UGC-PF-170 measure?
The piercing strength of food packaging film: the maximum force a Ø 1 mm needle needs to puncture film clamped over a Ø 20 mm opening, as in JIS Z 1707.
What is the load capacity?
250 N, about 56 lbf.
What is supplied?
Lower and upper 120 x 80 mm plates, a 55 x 80 mm clamping plate and a Ø 1 x 20 mm needle, all in stainless steel.
Which tester do I need?
A Mark-10 100 lb tensile tester covers the rating; a Galdabini 2.5 kN benchtop UTM also works.
What coupling does it have?
The coupling is made on request to suit your machine.
Can it test retort pouches and laminates?