Peel fixture with an adjustable angle and a linear-guided 60 x 230 mm test plate for thermoplastic tape, edge banding and laminated strips.
Brand: Universal Grip | Model: UGC-PL-050 | ● Configured to order
Peel angle set on a graduated segment for repeatable setups
Test plate on a linear guide along an inclined arm
60 x 230 mm (about 2.4 x 9.1 in) working surface
Knurled clamps hold the tape and the substrate
Small pincer grip and 200 g weight included to keep the specimen tensioned
Rated to 5 kN (about 1,124 lbf); steel and aluminum on a stable base
Downloads and standards
Trusted by Global Companies


























Tape peel fixture with adjustable peel angle
The UGC-PL-050 is a peel fixture for thermoplastic tape and similar bonded strips, built for labs that need to test peel strength at angles other than a fixed 90° or 180°. Typical users are manufacturers and processors of edge banding, adhesive tapes and laminated strips who want to see how a bond behaves at the angle it sees in production or in service.
How it works
The test plate is carried on a linear guide that runs along an inclined arm. The angle of the arm is set on a graduated segment, which fixes the angle at which the tape leaves the substrate. Knurled clamps hold the tape and substrate on the 60 x 230 mm (about 2.4 x 9.1 in) working surface. As the machine pulls, the plate moves along its guide, so the geometry chosen at the start is maintained over the length of the peel.
A small pincer grip takes hold of the free end of the tape, and a 200 g weight on a cable keeps the specimen tensioned. That light, constant tension keeps the tape from going slack and gives a consistent peel geometry from one specimen to the next.
Construction
Load rating: 5 kN (about 1,124 lbf), so the fixture rating leaves ample headroom over the peel force.
Build: steel and aluminum construction on a stable base.
Coupling: clevis pin coupling; other sizes are handled through our adapters.
Environment: intended for ambient-temperature testing.
Typical applications
Thermoplastic tapes, edge banding for furniture panels, adhesive tapes and laminated strips. The adjustable angle makes it useful in development work, where a bond is characterized at several angles before a production test angle is fixed. For 90° peel of flexible-to-rigid bonds on a sliding table, see the UGC-PL-150 90° peel fixture, and for 180° tape peel see the UGC-PL-140 180° tape peel fixture. The full range is on our peel fixtures page.
Machine fit
Because the fixture is rated well above most tape peel forces, the choice of frame is set by your peel forces rather than by the fixture. It can be fitted to Galdabini 5 kN benchtop universal testing machines or, for lower forces, to our 1,500 lb tensile tester.
Tell us the peel angle range you need, your tape width and your machine coupling, and we will configure the fixture. Request a quote.
Product video
At a glance
Max. load: 5 kN (approx. 1,124 lbf)
Test type: Peel at adjustable angle
Test plate: 60 x 230 mm working surface (approx. 2.4 x 9.1 in)
Plate guidance: Linear guide along an inclined arm
Peel angle: Adjustable, graduated scale; range on request
Specimen clamping: Knurled clamps for tape and substrate
Adjustable Angle Tape Peel Fixture Specifications
MAX. LOAD
5 kN (approx. 1,124 lbf)
TEST TYPE
Peel at adjustable angle
TEST PLATE
60 x 230 mm working surface (approx. 2.4 x 9.1 in)
PLATE GUIDANCE
Linear guide along an inclined arm
PEEL ANGLE
Adjustable, graduated scale; range on request
SPECIMEN CLAMPING
Knurled clamps for tape and substrate
ACCESSORIES
Small pincer grip and 200 g weight
MATERIAL
Steel and aluminum
COUPLING
Clevis pin coupling; other sizes via adapters
TEMPERATURE RANGE
Ambient
PART REF.
UGC-PL-050
Models & Options
Peel angle range — Angle range of the graduated segment, set to your method (Specify at order)
Tape width — Clamps and plate set up for your tape width (Specify at order)
Machine coupling — Clevis pin size or adapter to your machine (On request)
What's Included
Adjustable angle peel fixture with inclined arm, graduated segment and linear-guided test plate
Knurled clamps for tape and substrate
Small pincer grip for pulling the sample
200 g weight on a cable for specimen tension
Supported Test Standards
Standards list
Compatible Grips & Fixtures
UGC-PL-150 90 Degree Adhesive Peel Fixture ISO 8510-1 — Sliding-table 90° peel for flexible-to-rigid bonds
UGC-PL-140 180 Degree Tape Peel Fixture EN 1939 — 180° peel of adhesive tapes
5 kN Benchtop Testing Machine — Galdabini benchtop frame matched to the 5 kN rating
1500 lb Tensile Tester — Motorized frame for lower peel forces
Adapters — Couplings for other machine connections
Adhesives Testing — Peel, shear and tack testing of adhesives
“Customer quote”
Related Equipment
UGC-PL-140 180 Degree Tape Peel Fixture EN 1939
Carrier fixture for 180° peel adhesion tests on self-adhesive tapes to EN 1939, ISO 29862 and FINAT methods, with steel,
UGC-PL-150 90 Degree Adhesive Peel Fixture ISO 8510-1
Wire-driven sliding-table fixture that keeps the peel point centered at a constant 90° for flexible-to-rigid adhesive bo
UGC-PL-040 Yogurt Cup Peel Fixture
Vacuum cup holder on a graduated tilting segment for lid peel and seal strength tests on yogurt cups and similar sealed
UGC-PL-060 Sachet Packaging Tear Grip
Pair of 20 N pincer grips that imitate finger action to measure the tear-open force of sachets with serrated or V-notch
Adjustable Angle Tape Peel Fixture FAQ
How is the peel angle set on the UGC-PL-050?
On a graduated segment that sets the angle of the inclined arm carrying the test plate. Tell us the range you need when ordering.
What is the 200 g weight for?
It hangs on a cable and keeps the specimen tensioned, so the tape does not go slack and the peel geometry stays consistent.
How large is the test plate?
The working surface is 60 x 230 mm (about 2.4 x 9.1 in), with knurled clamps for the tape and substrate.
What is the maximum load?
5 kN (about 1,124 lbf). That is well above typical tape peel forces, so the load cell you choose is set by your specimen.
What comes with the fixture?
The fixture with its linear-guided test plate, a small pincer grip for pulling the sample and the 200 g weight.
How does it attach to my machine?
With a clevis pin coupling; other sizes via our adapters. Contact us with your machine model.