Home › Products › Peel Fixtures › 180 Degree Tape Peel Fixture EN 1939





180 Degree Tape Peel Fixture EN 1939 – Interchangeable Test Plates
Carrier fixture for 180° peel adhesion tests on self-adhesive tapes to EN 1939, ISO 29862 and FINAT methods, with steel, stainless or glass plates.
Brand: Universal Grip | Model: UGC-PL-140 | ● Configured to order
180° peel geometry for self-adhesive tapes, labels and protective films
Interchangeable test plates: stainless steel 1.4301, plain steel or float glass
Takes specimens up to 50 mm wide and 300 mm long (1.97 x 11.8 in)
Carrier rated for 10 kN (2,248 lbf)
Nickel-plated steel carrier, 2.4 kg
Female clevis coupling with Ø 15.9 mm (5/8 in) or Ø 20 mm pin
Standards: ISO 29862 · EN 1939 · FINAT FTM 1 · FINAT FTM 3
Trusted by Global Companies


























180° peel carrier for self-adhesive tapes and labels
The UGC-PL-140 is a carrier fixture for 180° peel adhesion tests on self-adhesive tapes, labels, protective films and other pressure-sensitive adhesives. It is built for tests to EN 1939, ISO 29862 and FINAT FTM 1, 3 and 4, giving tape manufacturers and converting QC labs one fixture that moves between methods by changing the test plate. See our complete ISO 29862 guide for specimen preparation, procedure and calculations.
How it works
The tape is applied to a test plate that sits vertically in the nickel-plated steel carrier. Its free end is folded back over itself and clamped in an upper grip, so as the crosshead rises the tape peels away from the plate at 180°. The carrier takes specimens up to 50 mm (1.97 in) wide and 300 mm (11.8 in) long.
Test plates for each method
Stainless steel 1.4301 – Ra 0.05 µm ±0.025, for EN 1939 and ISO 29862
Plain steel – untreated, for FINAT FTM 3
Float glass – for FINAT FTM 1, 3 and 4
Plates are interchangeable and ordered separately, so you can stock the surfaces your customers specify and change between them in the same carrier.
Ratings and coupling
The carrier is rated for 10 kN (2,248 lbf), far above typical tape peel forces, and weighs 2.4 kg. It connects through a female clevis with a Ø 15.9 mm (5/8 in) or Ø 20 mm pin, with other couplings on request. The standard working range is 0 to +70 °C, and other ranges are available on request.
Typical applications
Self-adhesive tapes
Labels and label stock
Protective films
Pressure-sensitive adhesives
Specimen application and machine fit
Consistent rolling pressure matters as much as the fixture, so application rollers are available: our 2 kg peel test sample roller (UGC-PL-200) is offered in standard and FINAT versions. Tape peel forces fit a Mark-10 F-series motorized tester as well as our Galdabini benchtop universal testing machines, and adapters cover other frames. The upper grip for the free tape end is ordered separately.
Let us know which standard you test to, the plate surfaces you need and your machine coupling, and we'll put the carrier, plates, roller and upper grip into one quote.
180 Degree Tape Peel Fixture EN 1939 Specifications
MAX. LOAD
10 kN (2,248 lbf)
TEST TYPE
180° peel
SPECIMEN SIZE
Max. 50 mm wide x 300 mm long
TEST PLATES
Stainless steel 1.4301, plain steel or float glass
STAINLESS PLATE FINISH
Ra 0.05 µm ±0.025
COUPLING
Female clevis Ø 15.9 mm (5/8 in) or Ø 20 mm pin; others on request
BODY MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
0 to +70 °C; other ranges on request
WEIGHT
2.4 kg (carrier)
SCOPE OF SUPPLY
1 carrier; test plates and upper grip ordered separately
PART REF.
UGC-PL-140
Models & Options
Carrier — 180° peel carrier, supplied without test plate (Specify at order)
Stainless steel plate — 1.4301, Ra 0.05 µm ±0.025, for EN 1939 and ISO 29862 (Specify at order)
Plain steel plate — Untreated, for FINAT FTM 3 (Specify at order)
Float glass plate — For FINAT FTM 1, 3 and 4 (Specify at order)
Application roller — 2 kg hand roller for applying specimens (UGC-PL-200) (Specify at order)
Other couplings — Alternatives to the clevis couplings to suit your machine (On request)
What's Included
1 nickel-plated steel 180° peel carrier
Test plates ordered separately in the material your method calls for
Upper grip for the free tape end ordered separately
Application rollers available as an add-on
Supported Test Standards
ISO 29862 — Self-adhesive tapes – determination of peel adhesion properties
EN 1939 — European method for peel adhesion of self-adhesive tapes
FINAT FTM 1 — 180° peel adhesion of self-adhesive materials
FINAT FTM 3 — Low-speed peel adhesion of self-adhesive materials
Compatible Grips & Fixtures
Peel Test Sample Roller (UGC-PL-200) — 2 kg hand roller for applying tape specimens
Motorized tensile testers — Mark-10 F-series testers for tape peel forces
Benchtop universal testing machines — Galdabini frames from 2.5 kN
Tensile grips — Upper grip options for the free tape end
Adhesives testing — Other peel, tack and bond test fixtures
“Customer quote”
Related Equipment
UGC-PL-200 Peel Test Sample Roller
2 kg polyurethane-coated hand roller that applies tape specimens to peel test panels with even pressure, in ASTM, EN/ISO
UGC-PL-130 German Wheel Peel Fixture
Free-rotating wheel fixture that holds a constant 90° peel angle on tapes, films, release coatings and flexible circuits
UGC-PL-150 90 Degree Adhesive Peel Fixture ISO 8510-1
Wire-driven sliding-table fixture that keeps the peel point centered at a constant 90° for flexible-to-rigid adhesive bo
UGC-PL-120 90 Degree Adhesive Peel Grip DIN 40802
Six-roller 90° peel fixture that measures the adhesion of flexible films to rigid substrates up to 7 mm thick, rated 2 k
180 Degree Tape Peel Fixture EN 1939 FAQ
Which test plate do I need?
It depends on the method: stainless steel 1.4301 for EN 1939 and ISO 29862, untreated plain steel for FINAT FTM 3, and float glass for FINAT FTM 1, 3 and 4.
Are test plates and the upper grip included?
No. The fixture is supplied as one carrier; test plates and the upper grip are ordered separately so you only buy the surfaces you use.
What specimen size fits?
Specimens up to 50 mm (1.97 in) wide and 300 mm (11.8 in) long.
Where can I find the ISO 29862 procedure?
See our ISO 29862 guide for specimen preparation, test procedure and calculations. This page covers the fixture hardware.
Do I need an application roller?
Tape peel methods specify a defined rolling pressure when applying specimens. Our 2 kg peel test sample roller is available in standard and FINAT versions.
Why is the carrier rated for 10 kN?
The 10 kN (2,248 lbf) rating gives a large safety margin over typical tape peel forces, so the carrier can also run on larger frames without concern.