Home › Products › Peel Fixtures › Peel Test Sample Roller





Peel Test Sample Roller – 2 kg Polyurethane Hand Roller
2 kg polyurethane-coated hand roller that applies tape specimens to peel test panels with even pressure, in ASTM, EN/ISO, FINAT and FED-STD versions.
Brand: Universal Grip | Model: UGC-PL-200 | ● Configured to order
Defined roller mass of about 2 kg (4.4 lb) for repeatable specimen application
Wear-resistant polyurethane coating, 80 ± 5 Shore A
Nickel-plated steel core under the coating
Ergonomic handle in stainless steel and plastic
Versions for ASTM/EN/ISO tape methods, FINAT 06/2011 and FED-STD-141D
Prepares specimens for 90° and 180° peel fixtures
Standards: ASTM D3330 · ISO 29862 · EN 1939 · PSTC-101
Trusted by Global Companies


























2 kg hand roller for preparing peel test specimens
The UGC-PL-200 is a hand roller for applying adhesive tape specimens to peel test panels with an even, standardized pressure. Common tape peel methods call for a roller of defined mass to be passed over the specimen before testing, and uneven rolldown is an easy way to add scatter to peel results. This roller gives tape, label and protective film labs a controlled mass of about 2 kg (4.4 lb) for every specimen.
Construction
The roller core is nickel-plated steel covered with a wear-resistant polyurethane coating of 80 ± 5 Shore A, so the contact surface stays consistent through heavy daily use. An ergonomic handle in stainless steel and plastic lets the operator guide the roller across the specimen while the roller's own mass provides the pressure.
Versions by standard
Standard roller – 2040 ± 45 g (4.50 lb), for ASTM, EN/ISO, PSTC and JIS tape peel methods
FINAT roller – 2000 ± 50 g (4.41 lb), for FINAT 06/2011
FED-STD roller – approx. 2040 g, for FED-STD-141D
Specify your test standard when ordering so the correct version and mass are supplied. Roller width is confirmed on request.
Where it fits in the test
The roller prepares specimens for both 90° and 180° peel fixtures: lay the tape on the panel, make the number of passes at the speed your method specifies, then mount the panel in the fixture. Use it with our 180° peel test panel (UGC-PL-180) for ASTM D3330, the 180° tape peel fixture (UGC-PL-140) for EN 1939 and ISO 29862 work, or the sliding-table 90° peel fixture (UGC-PL-150). For the methods themselves, see our ASTM D3330 and ISO 29862 guides.
Typical applications
Adhesive tapes
Labels and label stock
Protective films
Peel test specimen preparation
Practical details
The roller is used from 0 to +70 °C as standard, with other ranges on request, and is supplied singly. If you run several test stations or standards, order one roller per station in the version its method calls for. More specimen preparation tools are on our accessories page.
Tell us the standards you test to and how many stations need a roller, and we'll quote the right versions alongside your peel fixtures.
Peel Test Sample Roller Specifications
FUNCTION
Specimen application to peel test panels
ROLLER MASS, STANDARD
2040 ± 45 g (4.50 lb)
ROLLER MASS, FINAT
2000 ± 50 g (4.41 lb)
ROLLER MASS, FED-STD-141D
Approx. 2040 g
ROLLER MATERIAL
Steel, nickel-plated, polyurethane-coated
COATING HARDNESS
80 ± 5 Shore A
ROLLER WIDTH
On request
HANDLE
Stainless steel and plastic
TEMPERATURE RANGE
0 to +70 °C; other ranges on request
SCOPE OF SUPPLY
1 roller
PART REF.
UGC-PL-200
Models & Options
Standard roller — 2040 ± 45 g, for ASTM, EN/ISO, PSTC and JIS tape peel methods (Specify at order)
FINAT roller — 2000 ± 50 g, for FINAT 06/2011 (Specify at order)
FED-STD roller — Approx. 2040 g, for FED-STD-141D (Specify at order)
What's Included
1 polyurethane-coated hand roller in the version specified
Test panels and peel fixture are ordered separately
Supported Test Standards
ASTM D3330 — Peel adhesion of pressure-sensitive tape
ISO 29862 — Self-adhesive tapes – determination of peel adhesion properties
EN 1939 — European method for peel adhesion of self-adhesive tapes
PSTC-101 — Peel adhesion of pressure-sensitive tape
Compatible Grips & Fixtures
180 Degree Peel Test Panel (UGC-PL-180) — Stainless steel panel for ASTM D3330 Method A
180 Degree Tape Peel Fixture EN 1939 (UGC-PL-140) — 180° carrier with interchangeable test plates
90 Degree Adhesive Peel Fixture ISO 8510-1 (UGC-PL-150) — Sliding-table 90° peel fixture
Accessories — Specimen preparation and test accessories
Adhesives testing — Peel and tack test equipment for adhesives
“Customer quote”
Related Equipment
UGC-PL-140 180 Degree Tape Peel Fixture EN 1939
Carrier fixture for 180° peel adhesion tests on self-adhesive tapes to EN 1939, ISO 29862 and FINAT methods, with steel,
UGC-PL-150 90 Degree Adhesive Peel Fixture ISO 8510-1
Wire-driven sliding-table fixture that keeps the peel point centered at a constant 90° for flexible-to-rigid adhesive bo
UGC-PL-180 180 Degree Peel Test Panel
Bright annealed stainless steel panel, 125 x 50 x 2 mm, for 180° peel adhesion tests on pressure-sensitive tapes to ASTM
UGC-PL-190 Loop Tack Test Fixture
Loop tack holder for pressure-sensitive adhesives, used for ASTM D6195, EN 1719 and FINAT FTM 9 tests with glass or stai
Peel Test Sample Roller FAQ
Why does the roller mass matter?
Tape peel methods specify the rolling pressure used to apply the specimen. A defined mass of about 2 kg (4.4 lb) gives the same application pressure on every specimen.
Which version should I order?
Order the standard roller (2040 ± 45 g) for ASTM, EN/ISO, PSTC and JIS tape methods, the FINAT roller (2000 ± 50 g) for FINAT 06/2011, or the FED-STD roller for FED-STD-141D.
What is the roller coated with?
A wear-resistant polyurethane coating of 80 ± 5 Shore A over a nickel-plated steel core.
Which fixtures is it used with?
Any 90° or 180° tape peel setup, for example our 180° peel test panel and 180° tape peel fixture.
How wide is the roller?
Roller width is confirmed on request. Tell us your specimen width and test standard and we'll confirm the version when you request a quote.
Where can I learn more about the test methods?
See our ASTM D3330 guide and ISO 29862 guide for specimen preparation and procedure.




