top of page

Home  ›  Products  ›  Shear Fixtures  ›  Single Shear Fastener Fixture NASM 1312-20

UGC-SF-010 single shear fastener fixture for NASM 1312-20 testing, 50 kN, by Universal Grip
UGC-SF-010 single shear fastener fixture for NASM 1312-20 testing, 50 kN, by Universal Grip
UGC-SF-010 Single Shear Fastener Fixture NASM 1312-20 by Universal Grip, view 2
UGC-SF-010 Single Shear Fastener Fixture NASM 1312-20 by Universal Grip, view 3
Product photo 4

Single Shear Fastener Fixture NASM 1312-20 – 50 kN

50 kN single shear fixture for aerospace bolts, pins and rivets, built to the NASM 1312-20 and MIL-STD-1312-20 Fig. 3a arrangement.

Brand: Universal Grip  |  Model: UGC-SF-010  |  ● Configured to order

  • Single shear plane laid out to NASM 1312-20 and MIL-STD-1312-20, Fig. 3a

  • 50 kN (about 11,240 lbf) maximum load for aerospace bolts and pins

  • Two hardened steel plates loaded in opposite directions shear the fastener cleanly

  • Hardened plates resist deformation at the shear plane, test after test

  • Plate hole sizes made to the fastener diameter you specify

  • Matching Ø 56 mm (2.2 in) compression platen available with the same coupling

  • Ø 31.8 mm (1-1/4 in) female clevis coupling; adapters on request

Standards: NASM 1312-20  ·  MIL-STD-1312-20

Trusted by Global Companies

Single shear fixture for aerospace fastener qualification

The UGC-SF-010 measures the single shear strength of bolts, pins and rivets. It is laid out to the single shear arrangement of NASM 1312-20 and MIL-STD-1312-20, Fig. 3a, the method fastener manufacturers and aerospace qualification labs use to show that a fastener carries its rated shear load across one joint plane. The fixture is rated to 50 kN (about 11,240 lbf), which covers a wide band of aerospace hardware.

 

How it works

The fastener passes through two hardened steel plates. As the machine moves, the plates are loaded in opposite directions and the fastener is sheared across a single plane where the plates meet. Because there is only one shear plane, the result reflects how a fastener behaves in a lap-type joint, as opposed to the double shear clevis condition. Hardened plates matter here: if the hole edges roll over or the plates spread, the fastener sees bending as well as shear and the result drifts low. Hardened plates keep the shear plane crisp over many tests.

 

Plates, platen and coupling

Fastener diameters are not fixed in a catalog table. You tell us the fastener size and the plate hole sizes your specification calls for, and the plates are made to suit. The fixture connects with a Ø 31.8 mm (1-1/4 in) female clevis. A matching Ø 56 mm (2.2 in) steel compression platen with the same coupling is available for the test setup, so both parts mount on the same machine connection. Frames with a different connection can be fitted with coupling adapters.

 

Typical applications

  • Aerospace bolts and pins

  • Aerospace rivets

  • Lot acceptance and qualification testing in fastener labs

  • Comparing fastener materials, coatings and head styles in single shear

 

Related fixtures and machine fit

If your procedure calls for double shear, the UGC-SF-120 double shear fastener fixture covers NASM 1312-13 for fasteners up to 6.3 mm. For simple routine checks of bolts and pins, the UGC-SF-200 bolt and pin shear platens are an alternative. Fastener tensile tests on the same frame use our bolt grips. At 50 kN, the fixture belongs on a Galdabini 50 kN benchtop universal testing machine or a floor-standing frame; motorized force testers that top out at 1,500 lbf are too small for most aerospace fastener sizes.

The standard version runs at ambient temperature, with other ranges on request. Dimensional drawings and 3D models are available before you order. Send us the fastener diameter, required plate hole sizes, expected maximum load and your machine coupling, and we will configure the fixture: request a quote.

Product video

At a glance

  • Test type: Single shear of fasteners

  • Arrangement: NASM 1312-20 / MIL-STD-1312-20, Fig. 3a

  • Max. load: 50 kN (11,240 lbf)

  • Shear planes: One

  • Coupling: Female clevis, Ø 31.8 mm (1-1/4 in) pin

  • Material: Steel, hardened shear plates

Single Shear Fastener Fixture NASM 1312-20 Specifications

TEST TYPE

Single shear of fasteners

 

ARRANGEMENT

NASM 1312-20 / MIL-STD-1312-20, Fig. 3a

 

MAX. LOAD

50 kN (11,240 lbf)

 

SHEAR PLANES

One

 

COUPLING

Female clevis, Ø 31.8 mm (1-1/4 in) pin

 

MATERIAL

Steel, hardened shear plates

 

ACCESSORY

Compression platen Ø 56 mm, same coupling

 

FASTENER SIZE

On request

 

TEMPERATURE RANGE

Ambient (other ranges on request)

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-010

 

Models & Options

  • Single shear fixture, 50 kN — NASM 1312-20 Fig. 3a layout, plate holes made to your fastener diameter (Specify at order)

  • Compression platen Ø 56 mm — Steel platen with the same Ø 31.8 mm clevis coupling for the test setup (Specify at order)

  • Coupling adapters — For frames without a 1-1/4 in clevis connection (On request)

  • Non-ambient version — For test temperatures other than ambient (On request)

What's Included

  • Single shear fixture with hardened steel shear plates

  • Plate holes sized to the fastener diameter you specify

  • Ø 31.8 mm (1-1/4 in) female clevis coupling

  • Ø 56 mm compression platen is a separate item, ordered if your setup needs it

Supported Test Standards

  • NASM 1312-20 — Fastener test methods – single shear, Fig. 3a arrangement

  • MIL-STD-1312-20 — Military fastener test method – single shear, Fig. 3a

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-120 Double Shear Fastener Fixture NASM 1312-13

UGC-SF-120 Double Shear Fastener Fixture NASM 1312-13

Compression-mode double shear fixture that cuts fasteners up to 6.3 mm diameter across two planes for NASM 1312-13 shear

UGC-SF-200 Bolt and Pin Shear Platens

UGC-SF-200 Bolt and Pin Shear Platens

Clevis-mounted steel shear platens for single and double shear testing of bolts and pins in tension mode, with interchan

UGC-SF-020 Amsler Double Shear Fixture

UGC-SF-020 Amsler Double Shear Fixture

Amsler-type double shear fixture for 10 mm aluminum alloy rod and bar to ASTM B769, with replaceable hardened dies and a

UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238

UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238

Tension-mode double shear fixture for wires and rivets to EN 3238, with a split housing, central blade and knurled clamp

Single Shear Fastener Fixture NASM 1312-20 FAQ

Which test method is the UGC-SF-010 laid out for?

The single shear arrangement of NASM 1312-20 and MIL-STD-1312-20, Fig. 3a. The fastener is sheared across one plane between two plates loaded in opposite directions.

 

What fastener diameters can it test?

Fastener size is set at order. Tell us the diameter and the plate hole sizes your specification requires and the plates are made to suit.

 

What is the maximum load?

50 kN (about 11,240 lbf). Tell us the expected shear load of your largest fastener so we can confirm the fit.

 

Do I need the Ø 56 mm compression platen?

It is a matching steel platen with the same Ø 31.8 mm coupling, available for the test setup. We will confirm whether your configuration needs it when we quote.

 

I need double shear instead of single shear. Which fixture fits?

The UGC-SF-120 covers double shear to NASM 1312-13 for fasteners up to 6.3 mm.

 

Which testing machine should I use?

A Galdabini 50 kN benchtop machine or a floor-standing frame. Adapters connect the 1-1/4 in clevis to other couplings.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page