top of page

Home  ›  Products  ›  Shear Fixtures  ›  Double Shear Fixture for Wires and Rivets EN 3238

UGC-SF-030 tension-mode double shear fixture for wires and rivets to EN 3238 by Universal Grip
UGC-SF-030 tension-mode double shear fixture for wires and rivets to EN 3238 by Universal Grip
UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238 by Universal Grip, view 2
UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238 by Universal Grip, view 3
UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238 by Universal Grip, view 4

Double Shear Fixture for Wires and Rivets EN 3238

Tension-mode double shear fixture for wires and rivets to EN 3238, with a split housing, central blade and knurled clamping screw.

Brand: Universal Grip  |  Model: UGC-SF-030  |  ● Configured to order

  • Built for EN 3238 double shear testing of wires and rivets

  • Specimen sheared across two planes for a valid shear strength value

  • Inline layout runs in tension mode and fits standard tensile test setups

  • Split housing closed on the specimen with a knurled clamping screw

  • Hardened, nickel-plated steel shear components for long service life

  • Sized to your wire or rivet diameter at order

Standards: EN 3238  ·  ASTM B565

Trusted by Global Companies

Tension-mode double shear fixture for wires and rivets

The UGC-SF-030 determines the shear strength of wires and rivets to EN 3238. It is aimed at aerospace fastener makers, wire suppliers and production QC labs that need to verify the shear strength of rivet stock and finished rivets in aluminum, titanium and other fastener alloys. Because the fixture works in tension, it drops into a tensile test setup without converting the machine to compression.

 

How it works

The specimen passes through a split housing and a central blade. As the machine pulls the blade through the housing, the wire or rivet is sheared across two planes, one on each side of the blade. A knurled clamping screw closes the housing on the specimen before the test, so it cannot shift or rotate while the load builds. The inline layout keeps the load path on the machine's center line, the arrangement a tensile frame is built for.

 

Construction

The shear components are made of hardened, nickel-plated steel. The edges of the housing bore and blade define the two shear planes, and hardened edges hold their geometry over long runs of production tests, while the nickel plating protects the bore from corrosion between test series. The fixture connects with a clevis pin coupling; other sizes are handled through coupling adapters. Standard operation is at ambient temperature, with other ranges on request.

 

Typical applications

  • Aerospace rivets

  • Fastener wire

  • Aluminum and titanium wire

  • Fastener production QC

 

Sizing and related fixtures

Specimen diameter and maximum load are confirmed with your quote, because both depend on the wire or rivet you test. Tell us the diameter range and the highest shear load you expect, and the housing bore and blade are sized to match. Labs that also run ASTM B565 on aluminum rivets and wire use the same double shear principle; we will confirm whether your diameters can share the setup. For double shear of 10 mm aluminum alloy rod and bar in a compression-type Amsler fixture, the UGC-SF-020 to ASTM B769 is the better fit.

 

Machine fit

Fine wire shears at low loads, and small diameters can fit within the 1,500 lbf (6.7 kN) range of our motorized tensile testers. Larger rivets need a Galdabini benchtop universal testing machine. Send us the wire or rivet diameter, expected maximum load and your machine coupling, and we will configure the fixture: request a quote.

Product video

At a glance

  • Test type: Double shear, tension mode

  • Shear planes: Two

  • Specimens: Wires and rivets

  • Specimen diameter: On request

  • Max. load: On request

  • Housing: Split housing with knurled clamping screw

Double Shear Fixture for Wires and Rivets EN 3238 Specifications

TEST TYPE

Double shear, tension mode

 

SHEAR PLANES

Two

 

SPECIMENS

Wires and rivets

 

SPECIMEN DIAMETER

On request

 

MAX. LOAD

On request

 

HOUSING

Split housing with knurled clamping screw

 

COUPLING

Clevis pin coupling; other sizes via adapters

 

MATERIAL

Steel, hardened, nickel-plated

 

TEMPERATURE RANGE

Ambient (other ranges on request)

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-030

 

Models & Options

  • EN 3238 double shear fixture — Housing bore and blade sized to your wire or rivet diameter (Specify at order)

  • Coupling adapters — To fit the clevis coupling to your machine (On request)

  • Non-ambient version — For test temperatures other than ambient (On request)

What's Included

  • Double shear fixture with split housing, central blade and knurled clamping screw

  • Shear components sized to the diameter you specify

  • Clevis pin coupling; adapters for other couplings on request

Supported Test Standards

  • EN 3238 — Aerospace series – double shear testing of wires and rivets

  • ASTM B565 — Shear testing of aluminum rivets and cold-heading wire – related; confirm diameter

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-020 Amsler Double Shear Fixture

UGC-SF-020 Amsler Double Shear Fixture

Amsler-type double shear fixture for 10 mm aluminum alloy rod and bar to ASTM B769, with replaceable hardened dies and a

UGC-SF-040 Arcan Shear Test Fixture

UGC-SF-040 Arcan Shear Test Fixture

Angle-adjustable Arcan fixture for pure shear and mixed-mode tests on composites, clear wood and bonded joints, in 20 kN

UGC-SF-010 Single Shear Fastener Fixture NASM 1312-20

UGC-SF-010 Single Shear Fastener Fixture NASM 1312-20

50 kN single shear fixture for aerospace bolts, pins and rivets, built to the NASM 1312-20 and MIL-STD-1312-20 Fig. 3a a

UGC-SF-050 Reinforcing Steel Weld Shear Fixture EN 10080

UGC-SF-050 Reinforcing Steel Weld Shear Fixture EN 10080

50 kN weld shear fixture for welded joints in reinforcing steel to EN 10080, with 6 mm and 9 mm inserts at test angles o

Double Shear Fixture for Wires and Rivets EN 3238 FAQ

What does the UGC-SF-030 test?

The double shear strength of wires and rivets to EN 3238. The specimen is sheared across two planes as the blade is pulled through the housing.

 

Does it run in tension or compression?

Tension. The inline design fits a standard tensile setup, so the machine does not need to be converted to compression.

 

Which wire and rivet diameters can it take?

The housing bore and blade are sized to your diameter at order. Tell us the range you test.

 

What is the maximum load?

Maximum load is on request because it depends on specimen diameter. Send us your expected shear load and we will confirm the rating with the quote.

 

How is the specimen held?

A knurled clamping screw closes the split housing on the specimen, so it stays in place as load is applied.

 

Can it also be used for ASTM B565?

B565 uses the same double shear principle for aluminum rivets and wire. We will confirm whether your diameters suit the fixture; see our ASTM B565 guide.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page