top of page

Home  ›  Products  ›  Shear Fixtures  ›  Reinforcing Steel Weld Shear Fixture EN 10080

UGC-SF-050 reinforcing steel weld shear fixture with interchangeable angle inserts for EN 10080 by Universal Grip
UGC-SF-050 reinforcing steel weld shear fixture with interchangeable angle inserts for EN 10080 by Universal Grip
UGC-SF-050 Reinforcing Steel Weld Shear Fixture EN 10080 by Universal Grip, view 2
UGC-SF-050 Reinforcing Steel Weld Shear Fixture EN 10080 by Universal Grip, view 3
Product photo 4

Reinforcing Steel Weld Shear Fixture EN 10080

50 kN weld shear fixture for welded joints in reinforcing steel to EN 10080, with 6 mm and 9 mm inserts at test angles of 40° to 70°.

Brand: Universal Grip  |  Model: UGC-SF-050  |  ● Configured to order

  • Weld shear testing of weldable reinforcing steel to DIN EN 10080

  • Interchangeable inserts with 6 mm and 9 mm bores

  • Test angles of 40°, 50°, 60° and 70° set by the insert

  • Rated to 50 kN (about 11,240 lbf) maximum test load

  • One holder accepts all inserts, so changing size or angle is quick

  • Nickel-plated steel holder and inserts; Ø 40 mm female clevis coupling

Standards: EN 10080

Trusted by Global Companies

Weld shear fixture for welded reinforcing steel

The UGC-SF-050 tests the shear strength of welded joints in weldable reinforcing steel to DIN EN 10080. Rebar producers, mesh and cage fabricators and construction materials labs use it to prove that a weld between bars carries the load it must before the reinforcement goes into concrete. The fixture is rated to 50 kN (about 11,240 lbf) and connects to the machine with a Ø 40 mm female clevis.

 

How it works

A holder accepts interchangeable inserts. Each insert has a bore for the bar and a fixed test angle, so the welded joint is positioned and loaded at exactly the angle the test calls for. To move from one bar size or angle to the next, you swap the insert, not the fixture. That keeps setups repeatable from shift to shift and cuts down on handling of heavy parts at the machine. Weld shear checks matter because a mesh or cage is only as strong as its weakest joint during transport and placement, and a routine production test catches weak welds before the steel leaves the plant.

 

Inserts and versions

  • Holder: accepts all inserts.

  • Inserts Ø 6 mm (0.24 in): test angles 40°, 50°, 60° and 70°.

  • Inserts Ø 9 mm (0.35 in): test angles 40°, 50°, 60° and 70°.

That gives eight bore and angle combinations from one holder. Order only the combinations your production program needs. If you test other bar diameters, tell us the size when you order. Holder and inserts are made of nickel-plated steel for corrosion resistance in labs where specimens arrive straight from the yard.

 

Typical applications

  • Welded reinforcing steel

  • Reinforcement mesh

  • Rebar cages

  • Construction materials labs

 

Related fixtures

For weld shear of lattice girders and welded wire fabric to DIN 488, ISO 15630-2 and the ASTM welded wire standards, with bar diameters from 3 to 32 mm and capacities up to 250 kN, see the UGC-SF-190 reinforced concrete shear fixture. Tensile tests on the same bars use our wedge grips.

 

Machine fit

At 50 kN, the fixture suits a Galdabini 50 kN benchtop universal testing machine or a floor-standing frame already used for rebar tensile tests. If your machine has a different coupling, adapters connect it to the Ø 40 mm clevis. The fixture runs at ambient temperature. Tell us your bar diameters, the test angles you need and your machine coupling, and we will put together the holder and insert set: request a quote.

Product video

At a glance

  • Test type: Shear of welded reinforcing steel joints

  • Max. load: 50 kN (11,240 lbf)

  • Insert bores: 6 mm and 9 mm

  • Test angles: 40°, 50°, 60°, 70°

  • Insert combinations: 8 (2 bores x 4 angles)

  • Coupling: Female clevis, Ø 40 mm pin

Reinforcing Steel Weld Shear Fixture EN 10080 Specifications

TEST TYPE

Shear of welded reinforcing steel joints

 

MAX. LOAD

50 kN (11,240 lbf)

 

INSERT BORES

6 mm and 9 mm

 

TEST ANGLES

40°, 50°, 60°, 70°

 

INSERT COMBINATIONS

8 (2 bores x 4 angles)

 

COUPLING

Female clevis, Ø 40 mm pin

 

MATERIAL

Steel, nickel-plated

 

TEMPERATURE RANGE

Ambient

 

STANDARD

EN 10080

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-050

 

Models & Options

  • Holder — Accepts all inserts, Ø 40 mm female clevis (Specify at order)

  • Inserts Ø 6 mm — Test angles 40°, 50°, 60°, 70° (Specify at order)

  • Inserts Ø 9 mm — Test angles 40°, 50°, 60°, 70° (Specify at order)

  • Other bar diameters — Special insert bores (On request)

  • Coupling adapters — For machines without a Ø 40 mm clevis (On request)

What's Included

  • Holder and inserts are listed separately: order the holder plus the bore and angle inserts you need

  • Ø 40 mm female clevis coupling on the holder

  • Adapters for other couplings on request

Supported Test Standards

  • EN 10080 — Steel for the reinforcement of concrete – weldable reinforcing steel

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488

UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488

Weld shear fixtures for reinforcing steel lattice girders and welded wire fabric, bar diameters 3–32 mm and capacities f

UGC-SF-040 Arcan Shear Test Fixture

UGC-SF-040 Arcan Shear Test Fixture

Angle-adjustable Arcan fixture for pure shear and mixed-mode tests on composites, clear wood and bonded joints, in 20 kN

UGC-SF-060 Dental Crown Shear Bond Fixture ISO 10477

UGC-SF-060 Dental Crown Shear Bond Fixture ISO 10477

1 kN shear bond fixture for polymer-based crown and veneering materials to ISO 10477, with a graduated slide and screw-a

UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238

UGC-SF-030 Double Shear Fixture for Wires and Rivets EN 3238

Tension-mode double shear fixture for wires and rivets to EN 3238, with a split housing, central blade and knurled clamp

Reinforcing Steel Weld Shear Fixture EN 10080 FAQ

Which standard is the UGC-SF-050 built for?

Weld shear testing of weldable reinforcing steel to DIN EN 10080.

 

Which bar sizes and angles are covered?

Inserts with 6 mm and 9 mm bores, each at 40°, 50°, 60° and 70°. Other bar diameters are available on request.

 

Do I have to buy all eight inserts?

No. Holder and inserts are separate items, so you order the holder and only the bore and angle combinations you need.

 

What is the maximum load?

50 kN (about 11,240 lbf).

 

What coupling does it use?

A Ø 40 mm female clevis. Adapters connect it to other machine couplings.

 

I test welded wire fabric to ISO 15630-2. Is this the right fixture?

For welded fabric and lattice girders, the UGC-SF-190 covers DIN 488, ISO 15630-2 and the ASTM welded wire standards.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page