Home  ›  Products  ›  Shear Fixtures  ›  Reinforced Concrete Shear Fixture DIN 488

UGC-SF-190 weld shear fixture for reinforcing steel lattice girders and welded fabric by Universal Grip
UGC-SF-190 weld shear fixture for reinforcing steel lattice girders and welded fabric by Universal Grip
UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488 by Universal Grip, view 2
UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488 by Universal Grip, view 3
UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488 by Universal Grip, view 4

Reinforced Concrete Shear Fixture DIN 488 – Weld Shear

Weld shear fixtures for reinforcing steel lattice girders and welded wire fabric, bar diameters 3–32 mm and capacities from 50 kN to 250 kN.

Brand: Universal Grip  |  Model: UGC-SF-190  |  ● Configured to order

  • Shears the welded joint between cross wire and longitudinal bar

  • Versions for DIN 488, ASTM C1452, ISO 15630-2 and ASTM A185, A497, A974, A1064

  • Bar diameters from 3 mm to 32 mm (0.12–1.26 in), by version

  • Capacities from 50 kN to 250 kN (11,240–56,200 lbf)

  • Mounts by Ø 31.8 mm clevis, flange adapter or threaded rod

  • Nickel-plated steel body, 4.9–12.9 kg by version

Standards: ASTM C1452  ·  DIN 488  ·  ISO 15630-2  ·  ASTM A1064

Trusted by Global Companies

Weld shear testing for lattice girders and welded wire fabric

The UGC-SF-190 is a family of weld shear fixtures for producers and test labs that verify the welded joints of reinforcing steel: lattice girders, welded wire fabric, reinforcement mesh and wire gabions. The fixture supports the cross wire while the longitudinal bar is pulled, so the weld between them is loaded in shear until it fails. The result tells you whether the joint can transfer the anchorage force the reinforcement design relies on.

For reinforced autoclaved aerated concrete elements, see our complete ASTM C1452 guide for specimen preparation, procedure and calculations.

 

Versions

  • DIN 488 / ASTM C1452 – bars Ø 3–16 mm; flange adapter or threaded rod mounting; 12.9 kg

  • ISO 15630-2 / ASTM C1452, 100 kN – welded fabric, Ø 3–16 mm

  • ISO 15630-2 / ASTM C1452, 250 kN – welded fabric, Ø 3–16 mm

  • ASTM A185 / A497 / A974 / A1064 – wire Ø 3–8 mm; 200 kN, or 50 kN with the Ø 31.8 mm clevis; 7.5 kg

  • ISO 15630-2 (BS 4483) – Ø 4–12 mm; 50 kN; 4.9 kg

  • ISO 15630-2, Ø 4–16 mm – 50 kN; Ø 31.8 mm clevis

Versions for larger bars up to Ø 32 mm and for welded gabion mesh to EN 10223-8 are available on request.

 

Mounting and load train

Each fixture mounts to the machine by a female clevis with a Ø 31.8 mm (1-1/4 in) pin, a flange adapter or a threaded rod, depending on the version; other couplings and adapters are available. One fixture is supplied; the lower grip that holds the longitudinal bar is ordered separately, usually from our wedge grips sized to the bar diameter. The body is nickel-plated steel, specified for 0 to +70 °C; other ranges on request.

 

Choosing the machine

The 50 kN and 100 kN versions suit a 100 kN benchtop universal testing machine. The 200 kN and 250 kN versions call for a floor-standing machine or one of our hydraulic universal testing machines, which many rebar labs already use for tensile tests on the same bar.

 

Typical applications

  • Lattice girders

  • Welded wire fabric and reinforcement mesh

  • Welded wire reinforcement to the ASTM A1064 family

  • Wire gabions

For angle-adjustable weld shear of reinforcing bars to EN 10080, see UGC-SF-050, the reinforcing steel weld shear fixture. Tell us the standard, bar diameter range, required capacity and mounting, and we will quote the fixture and lower grip together.

Product video

At a glance

  • Test type: Weld shear of reinforcing steel

  • Max. load: 50–250 kN, by version

  • Bar diameter: 3–32 mm, by version

  • Coupling: Female clevis Ø 31.8 mm (1-1/4 in), flange adapter or threaded rod; others on request

  • Material: Steel, nickel-plated

  • Temperature range: 0 … +70 °C (others on request)

Reinforced Concrete Shear Fixture DIN 488 Specifications

TEST TYPE

Weld shear of reinforcing steel

 

MAX. LOAD

50–250 kN, by version

 

BAR DIAMETER

3–32 mm, by version

 

COUPLING

Female clevis Ø 31.8 mm (1-1/4 in), flange adapter or threaded rod; others on request

 

MATERIAL

Steel, nickel-plated

 

TEMPERATURE RANGE

0 … +70 °C (others on request)

 

WEIGHT

4.9–12.9 kg, by version

 

SCOPE OF DELIVERY

1 fixture; lower grip ordered separately

 

STANDARDS

DIN 488, ASTM C1452, ISO 15630-2, ASTM A185, A497, A974, A1064, EN 10223-8

 

PART REF.

UGC-SF-190

 

Models & Options

  • DIN 488 / ASTM C1452 — Ø 3–16 mm; flange adapter or threaded rod; 12.9 kg (Specify at order)

  • ISO 15630-2 / ASTM C1452, 100 kN — Welded fabric, Ø 3–16 mm (Specify at order)

  • ISO 15630-2 / ASTM C1452, 250 kN — Welded fabric, Ø 3–16 mm (Specify at order)

  • ASTM A185 / A497 / A974 / A1064 — Ø 3–8 mm; 200 kN (50 kN with Ø 31.8 mm clevis); 7.5 kg (Specify at order)

  • ISO 15630-2 (BS 4483) — Ø 4–12 mm; 50 kN; 4.9 kg (Specify at order)

  • ISO 15630-2, Ø 4–16 mm — 50 kN; Ø 31.8 mm clevis (Specify at order)

  • Larger bars and gabion mesh — Up to Ø 32 mm; EN 10223-8 welded mesh (On request)

What's Included

  • 1 weld shear fixture in the version ordered

  • Mounting as specified: Ø 31.8 mm clevis, flange adapter or threaded rod

  • Lower grip for the longitudinal bar is ordered separately

Supported Test Standards

  • ASTM C1452 — Reinforced autoclaved aerated concrete elements

  • DIN 488 — Reinforcing steels – lattice girders and welded fabric

  • ISO 15630-2 — Steel for the reinforcement of concrete – test methods – welded fabric

  • ASTM A1064 — Carbon-steel wire and welded wire reinforcement for concrete

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-050 Reinforcing Steel Weld Shear Fixture EN 10080

UGC-SF-050 Reinforcing Steel Weld Shear Fixture EN 10080

50 kN weld shear fixture for welded joints in reinforcing steel to EN 10080, with 6 mm and 9 mm inserts at test angles o

UGC-SF-170 Adhesive Shear Strength Fixture ISO 13445

UGC-SF-170 Adhesive Shear Strength Fixture ISO 13445

Block-shear fixture for adhesive bonds between rigid substrates, rated to 20 kN, with interchangeable inserts for ASTM D

UGC-SF-200 Bolt and Pin Shear Platens

UGC-SF-200 Bolt and Pin Shear Platens

Clevis-mounted steel shear platens for single and double shear testing of bolts and pins in tension mode, with interchan

UGC-SF-160 Plywood Glue Bond Shear Fixture EN 314-1

UGC-SF-160 Plywood Glue Bond Shear Fixture EN 314-1

Compact compression shear fixture with polyamide jaws for checking the glue bond quality of plywood specimens to EN 314-

Reinforced Concrete Shear Fixture DIN 488 FAQ

What does the fixture test?

The shear strength of the weld between a cross wire and a longitudinal bar in lattice girders, welded wire fabric and mesh.

 

Which bar diameters are covered?

From 3 mm to 32 mm depending on version. Most versions cover Ø 3–16 mm; the ASTM A185/A497/A974/A1064 version covers Ø 3–8 mm.

 

Is it used for ASTM C1452?

Yes, several versions are set up for ASTM C1452 weld shear tests. See our ASTM C1452 guide for the method itself.

 

Is the lower grip included?

No. One fixture is supplied; order the lower grip for the bar separately, for example from our wedge grips.

 

What capacity do I need?

Versions range from 50 kN to 250 kN. Tell us the bar diameter and standard and we will recommend the version and a matching universal testing machine.

 

How does it mount to the machine?

By a Ø 31.8 mm (1-1/4 in) female clevis, a flange adapter or a threaded rod, depending on version; adapters are available for other couplings.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page