Dental Adhesion Shear Fixture ISO TS 11405

Shear fixture for measuring adhesion to tooth structure to ISO/TS 11405, with a cage holder for embedded teeth and a Ø 10 mm, 30° shear pin.

Brand: Universal Grip  |  Model: UGC-SF-080  |  ● Configured to order

  • Built for adhesion-to-tooth shear testing to ISO/TS 11405

  • Pointed shear pin, Ø 10 mm with 30° tip angle, loads the bonded material

  • Cylindrical cage holder for embedded tooth specimens

  • Compact design for small, low-force testing machines

  • Accessory pins and adapters supplied with the fixture

  • Steel construction; maximum load confirmed to your test at quote

Standards: ISO/TS 11405

Trusted by Global Companies

Shear fixture for adhesion to tooth structure

The UGC-SF-080 measures how strongly dental adhesives and restorative materials bond to tooth structure, following ISO/TS 11405. Manufacturers of bonding agents, dental schools and research labs use it to compare adhesives, etching and priming steps, and bonding procedures on extracted teeth. The fixture is compact and made for small, low-force testing machines.

 

How it works

The tooth is embedded in a mounting cylinder and placed in a cylindrical cage holder, which locates it firmly with the bonded surface facing the loading direction. A pointed steel pin, Ø 10 mm (0.39 in) with a 30° tip angle, is driven against the bonded material and shears it off the tooth surface. The peak force divided by the bonded area gives the shear bond strength.

The cage holder is what makes the method repeatable. Embedded specimens vary in shape, and a holder that locates the embedding cylinder rather than the tooth itself keeps the bonded surface in the same position relative to the pin from one specimen to the next. A typical study bonds the same adhesive to enamel and to dentin, or compares bonding procedures, then shears groups of specimens after storage. The fixture's job is to make sure differences between those groups come from the adhesive, not from how each tooth was positioned.

 

Supplied items and coupling

Accessory pins and adapters are supplied with the fixture. It connects through a clevis pin coupling, and other sizes are handled with adapters. The fixture is made of steel and is used at ambient temperature. Maximum load is confirmed at quote; tell us your expected bond strength and specimen embedding size.

 

Typical applications

  • Dental adhesives

  • Bonding agents

  • Dental restorative materials

  • Dental research

 

Choosing between our dental shear fixtures

  • UGC-SF-080 (this fixture): adhesion to tooth structure with a pointed pin to ISO/TS 11405.

  • UGC-SF-310: notched-edge shearing of bonded restorative cylinders, similar to ISO 29022.

  • UGC-SF-060: shear bond of polymer crown and veneering materials to ISO 10477.

  • UGC-SF-330: general tooth sample shear with square or round inserts.

 

Machine fit

Dental bond forces are low, so the fixture suits Mark-10 F-series motorized testers as well as a Galdabini 2.5 kN benchtop universal testing machine. A low-capacity load cell gives the resolution that small bond forces need. Send us your specimen embedding size, expected maximum load and machine coupling, and we will configure the fixture: request a quote.

Product video

At a glance

  • Test type: Shear bond strength to tooth structure

  • Max. load: On request

  • Shear pin: Ø 10 mm, 30° angle

  • Specimen holder: Cylindrical cage holder

  • Specimen: Embedded tooth (embedding size on request)

  • Coupling: Clevis pin coupling; other sizes via adapters

Dental Adhesion Shear Fixture ISO TS 11405 Specifications

TEST TYPE

Shear bond strength to tooth structure

 

MAX. LOAD

On request

 

SHEAR PIN

Ø 10 mm, 30° angle

 

SPECIMEN HOLDER

Cylindrical cage holder

 

SPECIMEN

Embedded tooth (embedding size on request)

 

COUPLING

Clevis pin coupling; other sizes via adapters

 

MATERIAL

Steel

 

TEMPERATURE RANGE

Ambient

 

SUPPLIED ACCESSORIES

Pins and adapters

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-080

 

Models & Options

  • ISO/TS 11405 adhesion shear fixture — Cage holder sized to your embedding cylinder (Specify at order)

  • Coupling adapters — For your testing machine's connection (On request)

What's Included

  • Shear fixture with cylindrical cage holder

  • Shear pin, Ø 10 mm with 30° angle

  • Accessory pins and adapters

Supported Test Standards

  • ISO/TS 11405 — Dentistry – testing of adhesion to tooth structure

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-060 Dental Crown Shear Bond Fixture ISO 10477

UGC-SF-060 Dental Crown Shear Bond Fixture ISO 10477

1 kN shear bond fixture for polymer-based crown and veneering materials to ISO 10477, with a graduated slide and screw-a

UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022

UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022

Notched-edge shear fixture for the bond strength of dental restoratives to tooth structure, with a V-block specimen hold

UGC-SF-330 Tooth Sample Shear Fixture

UGC-SF-330 Tooth Sample Shear Fixture

Compact shear fixture for tooth samples with interchangeable 10 x 10 mm and 5 x 5 mm inserts, knurled side screws and a

UGC-SF-070 Biomass Shear Fixture

UGC-SF-070 Biomass Shear Fixture

10 kN shear fixture for cylindrical biomass samples such as pellets, briquettes and plant cores, with inserts for 20, 30

Dental Adhesion Shear Fixture ISO TS 11405 FAQ

What does the UGC-SF-080 measure?

The shear bond strength of adhesives and restorative materials to tooth structure, following ISO/TS 11405.

 

What shape is the shear pin?

A pointed pin with Ø 10 mm diameter and 30° tip angle.

 

How is the tooth held?

The tooth is embedded and placed in a cylindrical cage holder that locates the embedding, so the bonded surface sits in the same position for each test.

 

What is the maximum load?

Maximum load is on request. Dental bond forces are low; tell us your expected maximum and we will confirm the rating.

 

What comes with the fixture?

Accessory pins and adapters are supplied with it.

 

Which machine can I use?

A Mark-10 F-series motorized tester or a Galdabini 2.5 kN benchtop machine. Adapters handle the coupling.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.