top of page

Home  ›  Products  ›  Shear Fixtures  ›  Dental Restorative Bond Shear Fixture

UGC-SF-310 dental restorative notched-edge shear bond fixture with V-block holder by Universal Grip
UGC-SF-310 dental restorative notched-edge shear bond fixture with V-block holder by Universal Grip
UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022 by Universal Grip, view 2
UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022 by Universal Grip, view 3
UGC-SF-310 Dental Restorative Bond Shear Fixture ISO 29022 by Universal Grip, view 4

Dental Restorative Bond Shear Fixture – ISO 29022 Style

Notched-edge shear fixture for the bond strength of dental restoratives to tooth structure, with a V-block specimen holder and clevis-mounted tool.

Brand: Universal Grip  |  Model: UGC-SF-310  |  ● Configured to order

  • Notched-edge shear design similar to ISO 29022

  • V-block holder with two thumbscrews clamps the embedded tooth specimen

  • Notched shearing tool loads the bonded restorative cylinder at the interface

  • Compact steel construction for low-force dental bond testing

  • Upper loading tool mounts on a clevis adapter; other sizes via adapters

Standards: ISO 29022

Trusted by Global Companies

Notched-edge shear fixture for dental restorative bond strength

The UGC-SF-310 determines the adhesive bond strength between a dental restorative material and tooth structure. Its design follows the notched-edge shear approach of ISO 29022, and it is aimed at dental research labs and at manufacturers of dental adhesives, composite restoratives and cements who need a repeatable shear bond value.

 

How it works

A cylinder of restorative material is bonded to the prepared surface of a tooth, and the tooth is embedded in a mount. That embedded specimen is clamped in a V-block holder with two thumbscrews. The shearing tool, carried on the upper clevis adapter, has a notched edge that meets the bonded cylinder right at the interface, so the load goes into the bond rather than into the body of the cylinder. As the machine moves, the tool shears the cylinder off and the peak force is recorded.

The thumbscrews are turned by hand, so specimens change quickly across a test series. That helps when a study compares several adhesives, surface treatments or aging conditions and each group needs a full set of specimens tested under the same setup.

 

Specification notes

  • Max. load: on request. Tell us your expected bond strength and cylinder diameter.

  • Material: steel, compact construction for low-force testing.

  • Coupling: clevis pin coupling; other sizes via adapters.

  • Temperature: ambient.

 

Choosing among our dental shear fixtures

Universal Grip offers several fixtures for dental bond work. The UGC-SF-080 uses a cylindrical cage holder and a pointed Ø 10 mm shear pin for ISO/TS 11405. The UGC-SF-060 tests polymer-based crown and veneering materials to ISO 10477 at up to 1 kN. The UGC-SF-330 clamps loose tooth samples in interchangeable inserts. Pick the UGC-SF-310 when your protocol calls for a notched-edge tool acting on a bonded cylinder.

 

Machine fit

Dental bond tests run at low forces, so a Mark-10 F-series motorized tester (100–1,500 lbF) or a 2.5 kN benchtop UTM is the usual platform. Confirm the expected maximum load with us so we can match the fixture and coupling, using an adapter where needed.

Send the specimen embedding size, bonded cylinder diameter and your machine coupling, and we will quote the fixture.

Product video

At a glance

  • Test type: Shear bond strength, dental restoratives

  • Max. load: On request

  • Specimen holder: V-block with 2 thumbscrews

  • Shearing tool: Notched edge

  • Tool mounting: Upper clevis adapter

  • Coupling: Clevis pin coupling; other sizes via adapters

Dental Restorative Bond Shear Fixture Specifications

TEST TYPE

Shear bond strength, dental restoratives

 

MAX. LOAD

On request

 

SPECIMEN HOLDER

V-block with 2 thumbscrews

 

SHEARING TOOL

Notched edge

 

TOOL MOUNTING

Upper clevis adapter

 

COUPLING

Clevis pin coupling; other sizes via adapters

 

MATERIAL

Steel

 

TEMPERATURE RANGE

Ambient

 

DRAWINGS

Dimensional drawings and 3D models on request

 

PART REF.

UGC-SF-310

 

Models & Options

  • Standard fixture — V-block holder with thumbscrews and notched shearing tool on clevis adapter (Specify at order)

  • Specimen sizing — Holder and tool matched to your embedding size and bonded cylinder diameter (Specify at order)

  • Coupling adapters — For other machine connections (On request)

What's Included

  • V-block specimen holder with two thumbscrews

  • Notched-edge shearing tool on the upper clevis adapter

Supported Test Standards

  • ISO 29022 — Dentistry – notched-edge shear bond strength test (fixture designed similar to the standard)

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-060 Dental Crown Shear Bond Fixture ISO 10477

UGC-SF-060 Dental Crown Shear Bond Fixture ISO 10477

1 kN shear bond fixture for polymer-based crown and veneering materials to ISO 10477, with a graduated slide and screw-a

UGC-SF-080 Dental Adhesion Shear Fixture ISO TS 11405

UGC-SF-080 Dental Adhesion Shear Fixture ISO TS 11405

Shear fixture for measuring adhesion to tooth structure to ISO/TS 11405, with a cage holder for embedded teeth and a Ø 1

UGC-SF-330 Tooth Sample Shear Fixture

UGC-SF-330 Tooth Sample Shear Fixture

Compact shear fixture for tooth samples with interchangeable 10 x 10 mm and 5 x 5 mm inserts, knurled side screws and a

UGC-SF-300 Sapphire Glue Strength Shear Fixture

UGC-SF-300 Sapphire Glue Strength Shear Fixture

Special shear fixture for measuring the glue strength of bonded sapphire parts, with a rigid housing and inspection wind

Dental Restorative Bond Shear Fixture FAQ

Is this fixture made to ISO 29022?

It is designed similar to the notched-edge shear method of ISO 29022. Share your protocol and we will confirm the details.

 

How is the specimen held?

The embedded tooth specimen is clamped in a V-block holder with two thumbscrews.

 

How does it differ from the UGC-SF-080?

The UGC-SF-080 uses a cage holder and a pointed Ø 10 mm pin for ISO/TS 11405; the UGC-SF-310 uses a V-block and a notched-edge tool.

 

What is the maximum load?

On request. Tell us your expected bond strength and cylinder diameter.

 

What information do you need to quote?

The specimen embedding size, the bonded cylinder diameter and your machine coupling.

 

Which testing machine suits it?

A low-force frame such as a Mark-10 F-series tester or a 2.5 kN benchtop UTM.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page