top of page

Home  ›  Products  ›  Shear Fixtures  ›  Warner-Bratzler Meat Shear Fixture

UGC-SF-130 Warner-Bratzler meat shear fixture with V-notch blade by Universal Grip
UGC-SF-130 Warner-Bratzler meat shear fixture with V-notch blade by Universal Grip
UGC-SF-130 Warner-Bratzler Meat Shear Fixture by Universal Grip, view 2
UGC-SF-130 Warner-Bratzler Meat Shear Fixture by Universal Grip, view 3
UGC-SF-130 Warner-Bratzler Meat Shear Fixture by Universal Grip, view 4

Warner-Bratzler Meat Shear Fixture

V-notch blade shear fixture for measuring meat tenderness on cores up to 25 mm diameter, rated to 2 kN and built in stainless steel.

Brand: Universal Grip  |  Model: UGC-SF-130  |  ● Configured to order

  • Warner-Bratzler geometry: 1 mm V-notch blade with 0.5 mm cutting radius

  • Accepts cylindrical meat cores up to 25 mm (about 1 in) diameter

  • Rated to 2 kN (450 lbf) – fits motorized force testers and small benchtop frames

  • Stainless steel blade and guide for food contact and quick cleaning

  • Standard tension-mode version or guided compression-mode version

  • Female clevis Ø 15.9 mm or Ø 20 mm; other couplings on request

Downloads and standards

Trusted by Global Companies

Warner-Bratzler shear force testing for meat tenderness

The UGC-SF-130 gives meat processors, food research labs and universities an instrumental tenderness value to set beside sensory panel scores. A cylindrical core of meat is cut by a V-notch blade and the peak force recorded during the cut, the Warner-Bratzler shear force, is the result: the lower the force, the more tender the sample. Because the geometry is fixed, values can be compared across batches, cuts, aging times and cooking methods.

 

Blade and guide

The blade is 1 mm thick with a V-notch and a 0.5 mm cutting radius, the profile the method is known by. It runs through a slotted guide that keeps the core square to the blade so every sample is cut the same way. Cores up to 25 mm (about 1 in) diameter fit the notch. Blade and guide are stainless steel, suitable for food contact and easy to wipe down or wash between samples.

 

Two versions

  • Standard version – runs in tension mode with the slotted blade guide.

  • Special version – runs in compression mode, with a specimen support and blade guides, for labs that prefer to push the blade down through the core.

State which version you need when ordering, along with your machine coupling.

 

Machine fit

With a 2 kN (450 lbf) rating, the fixture sits comfortably on motorized force testers in the Mark-10 F-series class (100–1,500 lbF), such as our 500 lb tensile tester and 750 lb tensile tester. Research labs that also run other texture tests often choose a 2.5 kN benchtop universal testing machine. The standard coupling is a female clevis with a Ø 15.9 mm (5/8 in) or Ø 20 mm pin; other couplings and adapters are available. The operating range is 0 to +70 °C (32 to 158 °F); other ranges on request.

 

Typical applications

  • Tenderness of whole-muscle meat cuts

  • Poultry and fish texture

  • Benchmarking plant-based meat analogues against animal protein

  • Product development and shelf-life studies in food research labs

For multi-blade cutting of bulk samples, see UGC-SF-260, the Kramer shear cell, and the rest of our food testing fixtures. Tell us your core size, tester and coupling, and we will configure and quote the fixture.

Product video

At a glance

  • Test type: Shear / cutting force

  • Max. load: 2 kN (450 lbf)

  • Max. specimen diameter: 25 mm

  • Blade: V-notch, 1 mm thick, 0.5 mm cutting radius

  • Blade guide: Slotted (standard version)

  • Coupling: Female clevis Ø 15.9 mm or Ø 20 mm; others on request

Warner-Bratzler Meat Shear Fixture Specifications

TEST TYPE

Shear / cutting force

 

MAX. LOAD

2 kN (450 lbf)

 

MAX. SPECIMEN DIAMETER

25 mm

 

BLADE

V-notch, 1 mm thick, 0.5 mm cutting radius

 

BLADE GUIDE

Slotted (standard version)

 

COUPLING

Female clevis Ø 15.9 mm or Ø 20 mm; others on request

 

MATERIAL

Stainless steel

 

TEMPERATURE RANGE

0 … +70 °C (others on request)

 

WEIGHT

2.2 kg

 

DRAWINGS

Dimensional drawings on data sheet; 3D models on request

 

PART REF.

UGC-SF-130

 

Models & Options

  • Standard version — Tension mode, slotted blade guide (Specify at order)

  • Special version — Compression mode with specimen support and blade guides (Specify at order)

  • Clevis coupling — Female, Ø 15.9 mm or Ø 20 mm pin (Specify at order)

  • Other couplings or temperature ranges — Built to suit your machine and test conditions (On request)

What's Included

  • Warner-Bratzler fixture with V-notch blade and guide, in the version ordered

  • Coupling as specified (Ø 15.9 mm or Ø 20 mm female clevis)

  • Adapters for other machine couplings available on request

Supported Test Standards

Standards list

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-260 Kramer Shear Cell for Food

UGC-SF-260 Kramer Shear Cell for Food

Ten-blade Kramer shear-compression cell for measuring the firmness of fruit, vegetables, meat and processed foods, rated

UGC-SF-120 Double Shear Fastener Fixture NASM 1312-13

UGC-SF-120 Double Shear Fastener Fixture NASM 1312-13

Compression-mode double shear fixture that cuts fasteners up to 6.3 mm diameter across two planes for NASM 1312-13 shear

UGC-SF-140 Shear Fixture with Cardan Joints ISO 1922

UGC-SF-140 Shear Fixture with Cardan Joints ISO 1922

Self-aligning shear fixture with two cardan joints for sandwich cores, rigid foams and adhesive joints, in parallel, ang

UGC-SF-110 Wood Shear Test Fixture EN 13354

UGC-SF-110 Wood Shear Test Fixture EN 13354

5 kN compression shear fixture for wood and bonded solid wood panels to EN 13354, with a 10–60 mm adjustable jaw and Ø 2

Warner-Bratzler Meat Shear Fixture FAQ

What does a Warner-Bratzler test measure?

The peak force needed to cut a cylindrical meat core with a V-notch blade. Lower shear force indicates more tender meat.

 

What size samples does the fixture take?

Cores up to 25 mm (about 1 in) diameter.

 

Which version should I order?

The standard version runs in tension mode with a slotted blade guide. Choose the special version to work in compression mode with a specimen support and blade guides.

 

Will it run on a motorized force tester?

Yes. The 2 kN (450 lbf) rating suits our motorized tensile testers, and the fixture also fits small benchtop universal testing machines.

 

Is it suitable for food contact?

Yes. It is made of stainless steel and is easy to clean between samples.

 

Can I test meat analogues and fish?

Yes. Poultry, fish and plant-based meat analogues are typical applications alongside red meat. See our food testing fixtures for other texture methods.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page