Home › Products › Shear Fixtures › Shear Fixture with Cardan Joints ISO 1922





Shear Fixture with Cardan Joints ISO 1922
Self-aligning shear fixture with two cardan joints for sandwich cores, rigid foams and adhesive joints, in parallel, angled and adjustable versions.
Brand: Universal Grip | Model: UGC-SF-140 | ● Configured to order
Two cardan joints align the load path so the bonded specimen sees shear, not bending
Parallel version for ISO 1922 and EN 12090 Fig. 1
Angled (approx. 5°) version for ASTM C273 Fig. 2 and ASTM C394
Adjustable version: 0–110 mm shear width, up to 100 kN (22,480 lbf)
Supplied as a pair with 2 nickel-plated steel test plates, 50.8 x 330 x 15 mm
Spare test plates in packs of 1 or 5 pairs
Standards: ASTM C273 · ISO 1922 · EN 12090 · ASTM C394
Trusted by Global Companies


























Cardan-joint shear fixture for sandwich cores, foams and bonded joints
The UGC-SF-140 is a tension-loaded shear fixture for composites, insulation and adhesive labs that test sandwich core materials, rigid foams, honeycomb and structural adhesive joints. The specimen is bonded between two steel test plates, and the plates are pulled in opposite directions through a pair of cardan joints. Each joint lets its plate find the machine axis on its own, so the load passes through the specimen as shear instead of adding bending or peel at the plate ends.
Versions
Parallel shear – for ISO 1922 and EN 12090 Fig. 1; 6.7–7 kg per pair.
Angled shear, approx. 5° – for ASTM C273 Fig. 2 and ASTM C394; 7.6–9.6 kg per pair.
Adjustable, 0–110 mm – shear width set to the specimen, for parallel and angled set-ups including NF T54-605. Rated 100 kN for specimens 0–10 mm thick and 75 kN (16,860 lbf) for 11–20 mm, with a Ø 31.8 mm coupling.
The fixed versions are rated to 20 kN (4,496 lbf) with a Ø 15.9 mm (5/8 in) coupling or 35 kN (7,868 lbf) with a Ø 31.8 mm (1-1/4 in) coupling. See our complete ASTM C273 guide for specimen preparation, procedure and calculations.
Test plates
Each fixture ships as a pair with two test plates measuring 50.8 x 330 x 15 mm (2 x 13 x 0.59 in), in nickel-plated steel. Since specimens are bonded to the plates, labs running series often keep extra plates so the next specimens can cure while the current set is on the machine. Additional plates come in packs of 1 or 5 pairs.
Machine fit
The 20 kN version suits a 25 kN benchtop machine and the 35 kN version a 50 kN frame. The adjustable 100 kN version needs a 100 kN benchtop machine or a floor-standing universal testing machine. Couplings are female clevis Ø 15.9 mm or Ø 31.8 mm; other couplings and adapters are available. The standard operating range is 0 to +70 °C; other ranges on request.
Typical applications
Sandwich core materials for aerospace, marine and wind panels
Rigid foams and insulation boards
Honeycomb cores
Structural adhesive joints between rigid plates
For the symmetric two-specimen arrangement of EN 12090 Fig. 2b, see UGC-SF-090, the symmetric shear fixture. More options are on our shear fixtures page. Tell us the standard, specimen thickness and your machine coupling, and we will quote the right version and plate count.
Product video
At a glance
Test type: Shear, parallel or angled tensile loading
Max. load: 20 kN (Ø 15.9 mm) / 35 kN (Ø 31.8 mm); adjustable: up to 100 kN
Load introduction: Two cardan joints
Shear width: 0–110 mm (adjustable version)
Test plates: 50.8 x 330 x 15 mm
Coupling: Female clevis Ø 15.9 mm or Ø 31.8 mm; others on request
Shear Fixture with Cardan Joints ISO 1922 Specifications
TEST TYPE
Shear, parallel or angled tensile loading
MAX. LOAD
20 kN (Ø 15.9 mm) / 35 kN (Ø 31.8 mm); adjustable: up to 100 kN
LOAD INTRODUCTION
Two cardan joints
SHEAR WIDTH
0–110 mm (adjustable version)
TEST PLATES
50.8 x 330 x 15 mm
COUPLING
Female clevis Ø 15.9 mm or Ø 31.8 mm; others on request
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
0 … +70 °C (others on request)
WEIGHT
6.7–11.6 kg per pair, by version
SCOPE OF DELIVERY
1 pair with 2 test plates
STANDARDS
ISO 1922, EN 12090, ASTM C273, ASTM C394, NF T54-605
PART REF.
UGC-SF-140
Models & Options
Parallel shear — ISO 1922, EN 12090 Fig. 1; 6.7–7 kg per pair (Specify at order)
Angled shear, approx. 5° — ASTM C273 Fig. 2, ASTM C394; 7.6–9.6 kg per pair (Specify at order)
Adjustable, 0–110 mm — 100 kN (0–10 mm thick) / 75 kN (11–20 mm thick); Ø 31.8 mm coupling (Specify at order)
Test plates, 1 pair — 50.8 x 330 x 15 mm, steel, nickel-plated (Specify at order)
Test plates, 5 pairs — 50.8 x 330 x 15 mm, steel, nickel-plated (Specify at order)
What's Included
Shear fixture pair with two cardan joints, in the version ordered
2 test plates, 50.8 x 330 x 15 mm, nickel-plated steel
Spare test plates sold separately in packs of 1 or 5 pairs
Supported Test Standards
ASTM C273 — Shear properties of sandwich core materials
ISO 1922 — Rigid cellular plastics – determination of shear strength
EN 12090 — Thermal insulating products – determination of shear behavior
ASTM C394 — Shear fatigue of sandwich core materials
Compatible Grips & Fixtures
25 kN benchtop machine — For the 20 kN parallel and angled versions
50 kN benchtop machine — Covers the 35 kN versions
100 kN benchtop machine — For the adjustable 100 kN version
Foam testing — Fixtures for rigid foams and core materials
Adhesives testing — Shear, peel and tensile fixtures for bonded joints
Adapters — Fit Ø 15.9 or Ø 31.8 mm clevis to your machine
“Customer quote”
Related Equipment
UGC-SF-090 Symmetric Shear Fixture EN 12090
Lightweight anodized aluminum shear fixture for sandwich cores and insulation boards to EN 12090 Fig. 2b, loading two sp
UGC-SF-130 Warner-Bratzler Meat Shear Fixture
V-notch blade shear fixture for measuring meat tenderness on cores up to 25 mm diameter, rated to 2 kN and built in stai
UGC-SF-150 Ceramic Composite Shear Fixture
Compression shear fixture for notched fiber-reinforced ceramic specimens up to 10 mm thick, rated to 10 kN, for ASTM C12
UGC-SF-120 Double Shear Fastener Fixture NASM 1312-13
Compression-mode double shear fixture that cuts fasteners up to 6.3 mm diameter across two planes for NASM 1312-13 shear
Shear Fixture with Cardan Joints ISO 1922 FAQ
Why does the fixture use cardan joints?
The two cardan joints let each test plate self-align with the machine axis, so the bonded specimen is loaded in shear rather than bending.
Which version do I need for ASTM C273?
The angled (approx. 5°) version follows ASTM C273 Fig. 2, and the adjustable version can also be set up for C273. Our ASTM C273 guide covers specimen preparation and calculations.
Which version suits ISO 1922 or EN 12090?
The parallel shear version, built for ISO 1922 and EN 12090 Fig. 1. For the symmetric arrangement of EN 12090 Fig. 2b, see UGC-SF-090.
How thick can specimens be in the adjustable version?
Up to 20 mm. It is rated to 100 kN for specimens 0–10 mm thick and 75 kN for 11–20 mm.
Are test plates included?
Yes, each pair ships with 2 test plates of 50.8 x 330 x 15 mm. Spare plates are sold in packs of 1 or 5 pairs.
What couplings are available?
Female clevis with a Ø 15.9 mm (5/8 in) or Ø 31.8 mm (1-1/4 in) pin; other couplings and adapters on request.