Kramer Shear Cell for Food – 70 x 70 mm, 10 Blades

Ten-blade Kramer shear-compression cell for measuring the firmness of fruit, vegetables, meat and processed foods, rated to 20 kN.

Brand: Universal Grip  |  Model: UGC-SF-260  |  ● Configured to order

  • Standard 70 x 70 mm cell with 10 blades, 3 mm thick at 3 mm spacing

  • Combines compression, shear and extrusion in one stroke

  • Guide system keeps the blade set aligned in the cell

  • Fluid container collects juice and liquids released during the test

  • Rated to 20 kN (4,496 lbf); complete fixture weighs 9.6 kg (21.2 lb)

  • Full stainless version for -80 to +180 °C; custom 120 x 120 mm large cell

Downloads and standards

Trusted by Global Companies

Kramer shear cell for food firmness and texture

The UGC-SF-260 is a Kramer-type multi-blade shear cell for food labs measuring the firmness of fruits, vegetables, meat, poultry and processed foods. Because a whole bed of sample is sheared in one stroke, the reading reflects the bulk of the sample rather than a single cut, which makes the cell a common choice for QC checks and food texture research.

 

How it works

The sample is placed in the cell, and a set of parallel blades is driven down through it and out through matching slots in the base. In one stroke the product is compressed, sheared and extruded between the blades. A guide system keeps the blade set aligned with the slots, and a fluid container below collects juice and other liquids so they stay off the machine. The complete fixture also includes a lower compression platen Ø 156 mm (6.14 in).

 

Cell and blade options

  • Standard cell: 70 x 70 mm (2.76 x 2.76 in) with 10 blades, each 3 mm (0.12 in) thick, at 3 mm spacing.

  • Large cell (custom): 120 x 120 mm (4.72 x 4.72 in) with 9 blades, 5 mm thick, at 7 mm spacing, for bigger pieces or coarser products.

  • Full stainless version: rated from -80 to +180 °C (-112 to 356 °F) for chilled, frozen or heated samples.

The standard cell is built from stainless steel, aluminum and acrylic and is rated for -30 to +70 °C (-22 to 158 °F). Maximum load is 20 kN (4,496 lbf).

 

Machine fit

The cell connects through a female clevis with a Ø 15.9 mm (5/8 in) pin or an M8 internal thread; other couplings are available on request, along with adapters. To use the full 20 kN rating, run it on a 25 kN benchtop UTM. For softer produce, a Mark-10 F-series motorized tester (100–1,500 lbF, up to 6.7 kN) is a compact option, as long as the expected peak stays within the frame.

For single-blade meat tenderness tests, see the UGC-SF-130 Warner-Bratzler meat shear fixture, and browse the rest of our food testing fixtures.

Tell us your cell size and blade configuration, test temperature and machine coupling, and we will quote the cell.

Product video

At a glance

  • Test type: Shear-compression (Kramer)

  • Max. load: 20 kN (4,496 lbf)

  • Cell size: 70 x 70 mm (standard)

  • Blades: 10x, 3 mm thick, 3 mm spacing

  • Coupling: Female clevis Ø 15.9 mm (5/8 in) pin or M8 internal thread; others on request

  • Material: Stainless steel, aluminum, acrylic

Kramer Shear Cell for Food Specifications

TEST TYPE

Shear-compression (Kramer)

 

MAX. LOAD

20 kN (4,496 lbf)

 

CELL SIZE

70 x 70 mm (standard)

 

BLADES

10x, 3 mm thick, 3 mm spacing

 

COUPLING

Female clevis Ø 15.9 mm (5/8 in) pin or M8 internal thread; others on request

 

MATERIAL

Stainless steel, aluminum, acrylic

 

TEMPERATURE RANGE

-30 … +70 °C (full stainless version -80 … +180 °C)

 

WEIGHT

9.6 kg (21.2 lb) complete

 

LOWER PLATEN

Ø 156 mm, included

 

SCOPE OF DELIVERY

Cell, guide system, fluid container, lower platen

 

PART REF.

UGC-SF-260

 

Models & Options

  • Standard cell — 70 x 70 mm, 10 blades 3 mm thick, 3 mm spacing (Specify at order)

  • Large cell (custom) — 120 x 120 mm, 9 blades 5 mm thick, 7 mm spacing (On request)

  • Full stainless version — All-stainless construction for -80 … +180 °C (Specify at order)

  • Other couplings — Beyond Ø 15.9 mm clevis or M8 thread (On request)

What's Included

  • Kramer shear cell with blade set (10 blades in the standard cell)

  • Guide system for the blades

  • Fluid container

  • Lower compression platen, Ø 156 mm

Supported Test Standards

Standards list

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-130 Warner-Bratzler Meat Shear Fixture

UGC-SF-130 Warner-Bratzler Meat Shear Fixture

V-notch blade shear fixture for measuring meat tenderness on cores up to 25 mm diameter, rated to 2 kN and built in stai

UGC-SF-250 V-Notched Rail Shear Fixture

UGC-SF-250 V-Notched Rail Shear Fixture

Pair of V-notched rail shear grips for composites to ASTM D7078, in 50 kN and 100 kN versions plus a -100 to +600 °C hig

UGC-SF-270 O-Ring Composite Shear Fixture

UGC-SF-270 O-Ring Composite Shear Fixture

Special shear fixture for ring-shaped composite samples 70 to 170 mm in diameter, with stepped seats on two steel blocks

UGC-SF-240 Plastics Shear Punch Fixture

UGC-SF-240 Plastics Shear Punch Fixture

Punch-tool shear fixture for plastic sheet to ASTM D732 that cuts a 25.4 mm disk, offered as a 20 kN clevis version or a

Kramer Shear Cell for Food FAQ

What foods can the Kramer shear cell test?

Fruits and vegetables, meat and poultry, processed foods and samples for food texture research.

 

What blade configuration does the standard cell use?

Ten blades, each 3 mm thick, at 3 mm spacing, in a 70 x 70 mm cell. A custom 120 x 120 mm cell with nine 5 mm blades at 7 mm spacing is available on request.

 

What happens to juice released during the test?

It drains into the fluid container supplied with the cell, keeping liquids off the machine.

 

Can I test frozen or heated samples?

The standard cell covers -30 to +70 °C. The full stainless version extends that to -80 to +180 °C.

 

Which testing machine do I need?

A 25 kN benchtop UTM uses the full 20 kN rating. Softer products can run on a Mark-10 F-series tester up to 1,500 lbF if the peak force stays within that capacity.

 

Is a compression platen included?

Yes. The lower platen (Ø 156 mm), guide system and fluid container all come with the cell.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.