Adhesive Shear Strength Fixture ISO 13445 – Block Shear

Block-shear fixture for adhesive bonds between rigid substrates, rated to 20 kN, with interchangeable inserts for ASTM D4501 and ISO 13445 blocks.

Brand: Universal Grip  |  Model: UGC-SF-170  |  ● Configured to order

  • Block-shear set-up used for ASTM D4501, ISO 13445 and GOST R 57728

  • Rated to 20 kN (4,496 lbf) maximum test load

  • Inserts for 26 x 26 mm blocks (6 or 13 mm thick) and 25 x 18 mm blocks (13 mm thick)

  • Loading tool shears the specimen parallel to the bond line

  • Hardened, nickel-plated steel for long service life

  • MIL-P-25690 version and a 10 kN special with 80 x 80 mm insert

Standards: ASTM D4501  ·  ISO 13445  ·  GOST R 57728

Trusted by Global Companies

Block-shear testing of adhesive bonds between rigid substrates

The UGC-SF-170 is for adhesive manufacturers, bonding process engineers and development labs that need the shear strength of a bond between two rigid blocks: metal to metal, plastic to metal, or wood to wood. Unlike a lap-shear coupon, a bonded block does not bend under load, so the block-shear method loads the adhesive in shear with far less bending than a thin coupon. See our complete ASTM D4501 guide for specimen preparation, procedure and calculations.

 

How it works

The bonded block specimen sits in an interchangeable insert in the fixture body. A loading tool bears on the upper block and drives it parallel to the bond line, so the adhesive layer fails in shear. The insert locates the lower block and sets the specimen height, which is why the fixture ships without an insert: you order the insert, or several, that match your blocks.

Body and loading tool are hardened and nickel-plated, so the bearing faces keep their edges and resist corrosion over long test series.

 

Inserts and versions

  • Insert 26 x 26 mm, 6 mm thick

  • Insert 26 x 26 mm, 13 mm thick

  • Insert 25 x 18 mm, 13 mm thick

  • MIL-P-25690 version – with a 26 x 26 mm insert, 10 mm thick

  • Special version, 10 kN – with an 80 x 80 mm (3.15 x 3.15 in) insert, 8 mm thick, and a coupling with 2 cross holes

 

Machine fit

The 20 kN rating pairs with a 25 kN benchtop universal testing machine; a 10 kN frame is enough for the 10 kN special version or lower-strength adhesives. The standard coupling is a female clevis with a Ø 15.9 mm (5/8 in) pin; other couplings and adapters are available. The fixture is specified for 0 to +70 °C (32 to 158 °F); other ranges on request.

 

Typical applications

  • Structural adhesives for metals and engineering plastics

  • Bonded metal and plastic assemblies

  • Wood adhesives

  • Formulation screening in adhesive development labs

If your specimens are single-lap joints rather than blocks, our ASTM D1002 guide and ISO 4587 guide cover lap-shear testing, and our adhesives testing page lists the matching grips. Tell us the block size and thickness and your machine coupling, and we will quote the fixture with the right inserts.

Product video

At a glance

  • Test type: Block shear of adhesive bonds

  • Max. load: 20 kN (4,496 lbf)

  • Inserts: 26 x 26 mm (6 or 13 mm thick), 25 x 18 mm (13 mm thick)

  • Coupling: Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

  • Material: Steel, hardened, nickel-plated

  • Temperature range: 0 … +70 °C (others on request)

Adhesive Shear Strength Fixture ISO 13445 Specifications

TEST TYPE

Block shear of adhesive bonds

 

MAX. LOAD

20 kN (4,496 lbf)

 

INSERTS

26 x 26 mm (6 or 13 mm thick), 25 x 18 mm (13 mm thick)

 

COUPLING

Female clevis, Ø 15.9 mm (5/8 in) pin; others on request

 

MATERIAL

Steel, hardened, nickel-plated

 

TEMPERATURE RANGE

0 … +70 °C (others on request)

 

WEIGHT

3 kg (without insert)

 

SCOPE OF DELIVERY

Fixture without insert

 

SPECIAL VERSION

10 kN; 80 x 80 x 8 mm insert; coupling with 2 cross holes

 

STANDARDS

ASTM D4501, ISO 13445, GOST R 57728

 

PART REF.

UGC-SF-170

 

Models & Options

  • Insert 26 x 26 mm — 6 mm thick (Specify at order)

  • Insert 26 x 26 mm — 13 mm thick (Specify at order)

  • Insert 25 x 18 mm — 13 mm thick (Specify at order)

  • MIL-P-25690 version — Insert 26 x 26 mm, 10 mm thick (On request)

  • Special version, 10 kN — Insert 80 x 80 mm, 8 mm thick; coupling with 2 cross holes (On request)

What's Included

  • Block-shear fixture with loading tool, hardened nickel-plated steel

  • Ø 15.9 mm female clevis coupling (others on request)

  • Inserts are not included – order one or more to match your block size and thickness

Supported Test Standards

  • ASTM D4501 — Shear strength of adhesives between rigid substrates by the block-shear method

  • ISO 13445 — Adhesives – shear strength of bonds between rigid substrates by the block-shear method

  • GOST R 57728 — Russian national standard for the same block-shear test

Compatible Grips & Fixtures

“Customer quote”

Related Equipment

UGC-SF-160 Plywood Glue Bond Shear Fixture EN 314-1

UGC-SF-160 Plywood Glue Bond Shear Fixture EN 314-1

Compact compression shear fixture with polyamide jaws for checking the glue bond quality of plywood specimens to EN 314-

UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488

UGC-SF-190 Reinforced Concrete Shear Fixture DIN 488

Weld shear fixtures for reinforcing steel lattice girders and welded wire fabric, bar diameters 3–32 mm and capacities f

UGC-SF-150 Ceramic Composite Shear Fixture

UGC-SF-150 Ceramic Composite Shear Fixture

Compression shear fixture for notched fiber-reinforced ceramic specimens up to 10 mm thick, rated to 10 kN, for ASTM C12

UGC-SF-200 Bolt and Pin Shear Platens

UGC-SF-200 Bolt and Pin Shear Platens

Clevis-mounted steel shear platens for single and double shear testing of bolts and pins in tension mode, with interchan

Adhesive Shear Strength Fixture ISO 13445 FAQ

Which standards is this fixture used for?

Block-shear tests such as ASTM D4501, ISO 13445 and GOST R 57728. Our ASTM D4501 guide walks through specimen preparation and calculations.

 

Is an insert included?

No. The fixture ships without an insert so you can order the size that matches your blocks: 26 x 26 mm (6 or 13 mm thick) or 25 x 18 mm (13 mm thick).

 

What is the maximum load?

20 kN (4,496 lbf) for the standard fixture. The special version with an 80 x 80 mm insert is rated to 10 kN.

 

Can I test to MIL-P-25690?

Yes, a MIL-P-25690 version with a 26 x 26 mm, 10 mm thick insert is available on request.

 

How is block shear different from lap shear?

A bonded block stays rigid, so the adhesive is loaded in shear without the bending seen in thin lap-shear coupons. For lap shear, see our ASTM D1002 guide.

 

What machine do I need?

A 25 kN benchtop machine covers the full 20 kN rating; the coupling is a Ø 15.9 mm (5/8 in) female clevis.

 

Need help configuring a shear fixture?

Tell us your material, test standard and specimen size. We will recommend the frame, force sensor, grips and fixtures, and send a quote.

bottom of page