Home › Products › Shear Fixtures › V-Notched Beam Shear Fixture





V-Notched Beam Shear Fixture – Iosipescu, ASTM D5379
Iosipescu V-notched beam shear fixture for composite laminates, rated to 50 kN, with the compression probe and specimen jaws included.
Brand: Universal Grip | Model: UGC-SF-230 | ● Configured to order
Built for the Iosipescu V-notched beam shear method of ASTM D5379
Rated to 50 kN (11,240 lbf) maximum test load
Specimen opening 18–19.5 mm (0.71–0.77 in), 23 mm (0.91 in) maximum
Fixed half and sliding half create a uniform shear zone between the notches
Compression probe and specimen jaws ship with the fixture
Usable from -10 to +80 °C (14 to 176 °F); other ranges on request
Nickel-plated steel construction, 10 kg (22 lb)
Standards: ASTM D5379
Trusted by Global Companies


























Iosipescu V-notched beam shear fixture for composite materials
The UGC-SF-230 is a V-notched beam shear fixture for composite test labs that need shear properties by the Iosipescu method of ASTM D5379. It is built for fiber-reinforced composites and laminates, for composite R&D and for the aerospace materials qualification programs that depend on reliable shear data. The fixture arrives ready to test, with its compression probe and specimen jaws in the box.
How it works
The double-notched beam specimen is clamped across two halves of the fixture: one half is fixed, the other slides. When the testing machine drives the compression probe down, the probe displaces the sliding half relative to the fixed half. Because the load is introduced on either side of the notched section, the material between the two V-notches is put into a uniform shear zone instead of the mix of bending and shear produced by simpler beam tests.
See our complete ASTM D5379 guide for specimen preparation, procedure and calculations. This page covers the hardware itself.
Specimen fit and capacity
Specimen opening: 18–19.5 mm (0.71–0.77 in), with a maximum of 23 mm (0.91 in). Give us your specimen thickness when ordering and we will confirm the jaw setup.
Load: rated to 50 kN (11,240 lbf).
Temperature: -10 to +80 °C (14 to 176 °F) as standard; other ranges on request.
Construction: nickel-plated steel, 10 kg (22 lb).
Machine and coupling
The fixture connects through a female clevis with a Ø 31.8 mm (1-1/4 in) pin. Other couplings are available on request, and our adapters cover most other machine interfaces. The 50 kN rating pairs naturally with a 50 kN benchtop universal testing machine, and the fixture also fits the larger Galdabini floor-standing UTMs. For laminates tested away from room temperature, an environmental chamber can enclose the setup within the fixture's rated range.
Related shear fixtures
If your program calls for a larger shear zone and tension-mode loading, the UGC-SF-250 V-notched rail shear fixture for ASTM D7078 clamps a V-notched specimen between bolted rails. Our full range of composite, adhesive and fastener shear tooling is on the shear fixtures page.
Tell us your specimen thickness, test temperature and machine coupling, and we will configure the fixture and send you a quote.
V-Notched Beam Shear Fixture Specifications
TEST TYPE
V-notched beam shear (Iosipescu)
MAX. LOAD
50 kN (11,240 lbf)
SPECIMEN OPENING
18–19.5 mm (max. 23 mm)
LOADING
Compression probe displaces the sliding half
COUPLING
Female clevis, Ø 31.8 mm (1-1/4 in) pin; others on request
MATERIAL
Steel, nickel-plated
TEMPERATURE RANGE
-10 … +80 °C (others on request)
WEIGHT
10 kg (22 lb)
SCOPE OF DELIVERY
Fixture incl. compression probe and jaws
DRAWINGS
Dimensional drawing on data sheet; certified drawings and 3D models on request
PART REF.
UGC-SF-230
Models & Options
Standard fixture — Fixed and sliding halves, compression probe and jaws, Ø 31.8 mm female clevis (Specify at order)
Alternative coupling — Other clevis sizes or threaded connections to match your machine (On request)
Extended temperature range — For testing outside -10 … +80 °C (On request)
What's Included
V-notched beam shear fixture with fixed and sliding halves
Compression probe
Specimen jaws
Machine coupling as specified (Ø 31.8 mm female clevis as standard)
Supported Test Standards
ASTM D5379 — Shear properties of composite materials by the V-notched beam method
Compatible Grips & Fixtures
50 kN Benchtop UTM — Matches the fixture's 50 kN rating
Floor-Standing UTMs — Larger Galdabini frames for mixed composite programs
UGC-SF-250 V-Notched Rail Shear Fixture — ASTM D7078 rail shear grips for a larger shear zone
Adapters — Fit the Ø 31.8 mm clevis to other machine couplings
Environmental Chambers — Testing within the -10 to +80 °C range
“Customer quote”
Related Equipment
UGC-SF-250 V-Notched Rail Shear Fixture
Pair of V-notched rail shear grips for composites to ASTM D7078, in 50 kN and 100 kN versions plus a -100 to +600 °C hig
UGC-SF-220 Tile Adhesive Shear Fixture EN 12003
Compression shear fixture for tile adhesives and mortars with a 12–45 mm jaw opening, rated to 20 kN, for EN 1324 Fig. 2
UGC-SF-240 Plastics Shear Punch Fixture
Punch-tool shear fixture for plastic sheet to ASTM D732 that cuts a 25.4 mm disk, offered as a 20 kN clevis version or a
UGC-SF-210 Dispersion Adhesive Shear Fixture EN 1324
Shear adhesion fixture for dispersion and tile adhesives, rated to 20 kN, for EN 1324 Fig. 3, EN 12003 Fig. 3 and ISO 13
V-Notched Beam Shear Fixture FAQ
Which test method is the UGC-SF-230 for?
It is built for the Iosipescu V-notched beam shear test of ASTM D5379. Our ASTM D5379 guide covers specimens, procedure and calculations.
What specimen size does it accept?
The specimen opening is 18–19.5 mm, with a maximum of 23 mm. Tell us your specimen thickness when ordering and we will confirm the fit.
Is the compression probe included?
Yes. The compression probe and specimen jaws ship with the fixture.
How does it connect to my testing machine?
Through a female clevis with a Ø 31.8 mm (1-1/4 in) pin. Other couplings are available on request, and adapters cover most other interfaces.
Can I test above or below room temperature?
The standard fixture is usable from -10 to +80 °C. Other temperature ranges are available on request.
How is it different from the V-notched rail shear fixture?
The UGC-SF-230 loads a notched beam through a compression probe and a sliding half. The UGC-SF-250 clamps a V-notched specimen between bolted rails and loads it in tension to ASTM D7078.